N849AE
Service difficulty reports · 87
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N849AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N849AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA201911143007Light · inoperativeOVERHEAD COCKPIT EMER LIGHT INOP-C/A-REMOVED AND REPLACED OVERHEAD COCKPIT EMER LIGHT IAW AMM 33-50-05. OPS CHECK GOODSDR SIMA20190530003Tube · not reportedMEL 21-17 AUTH # 050951DM-C ORIGINAL LOG PAGE 4510226 ITEM 1. AUTO PRESS SYSTEM FAILED DURING CLIMB. AURAL WARNING. MANUAL PRESSURIZATION IS EXTREMLY SENSITIVE AND RANGES FROM -3000 TO + 3000 FEET/ MIN CAB RATE. C/A-REMOVED AND REPLACED OUTFLOW VALVES INTERCOSDR SIMA201902252001Static Inverter · failedAT 16000 DESCENDING INTO SUX 115 VAC BUS OFF. WINDSHEAR INOP GPWS INOP, TERR INOP. 3 MIN LATER WARM ELECTRICAL SMELL LASTED 2 MIN THEN WENT AWAY-C/A-REMOVED AND REINSTALLED 113AZ, 223KLW IAW EMB 140 AMM 06-41-01/06-41-03. PERFORMED GVI OF INVERTER AND OPERATEDSDR SIMA201812054001Seal · fodVERY LOUD SQUEALING AND WOOSHING NOISE COMING FROM MAIN CABIN DOOR AFTER TAKE OFF-C/A-FOUND OBJECT ON DOOR SEAL AND STICKER. REMOVED FROM MAIN CABIN DOOR SEAL AND PERFORMED PRESSURIZATION CHECK IAW 21-31-00. OPS CHECK GOOD NO SQUEELING SOUND NOTED.SDR SIMA20181203006Proximity Sensor · failedSPOILER FAIL MSG ON EICAS AND OPN INDICATION WHILE AT GATE AFTER STARTUP. REMOVED AND REPLACED OB RT SIDE PROXIMITY SWITCH IAW AMM 27-63-04. OPC GOOD IAW AMM 27-63-01. NO MESSAGES NOTED.SDR SIMA201811276007Warning Message · false activationICE CONDITION ANTI ICE INOP POSTED IN FLIGHT IN ICING CONDITIONS.-C/A-PERFORMED OPS CHECK OF ANTI ICE SYSTEM PER EMB 140 AMM 30-00-00. NO DEFECTS NOTED, NO CMC MSGS POSTED. A/C OKAY FOR SERVICE.SDR SIMA201811149002Warning Message · false indicationE2 A/ICE FAIL.-C/A-DEFERRED E2 A/ICE VALVE FAIL AS PER MEL 30-11. MTX PROCEDURES COMPLIED WITH A/C OK FOR SERVICE. PERFORMED T/S IAW EMB 140 FIM 30-80-00-810-804A FOUND TO BE TRANSITORY ON A/ICE ELECTRICAL CIRCUIT. PERFORMED OPS CHECK OF ICE DETECTION SYS. IAWSDR SIMA2018051706002Light · inoperativeEMERGENCY LIGHT ON MAIN DOOR DOES NOT ILLUMINATE. LIGHT WOULD ONLY COME ON WHEN HOUSING ASSEMBLY AT CONNECTOR END WAS PUSHED IN. REMOVED AND REPLACED THE EMERGENCY LIGHT ASSEMBLY IAW AMM 33-50-10. OPS CHECKED GOOD.SDR SIMA20180327001Smoke Warning · false activationBAGGAGE SMOKE EICAS T GATE, CARGO DOOR CLOSED. FLIGHT ATTENDANT SAW SMOKE IN CARGO BAY. PERFORMED ETN-EM-72-034. NO SMOKE IN CARGO BAY OR CABIN. OPS CHECKED GOODSDR SIMA20180306002Lamp · inoperativeFLASHLIGHT IN THE REAR CABIN IS INOPERATIVE. REPLACED THE LAMP IN THE FLASHLIGHT IAW CMM 25-60-11. OPS CHECKED GOOD.SDR SIMA20180224001Smoke Detector · false indicationCARGO SMOKE WARNING DURING TAXI IN. RAN PROCEDURE AND EXTINUISHED THE CARGO BOTTLE. CFR FOUND 1 BAG ON FIRE. INSPECTED CARGO BAY IAW AMM 25-51-01, NO DAMAGE FOUND, CFR ACTUALLY FOUND NO EVIDENCE OF A BURNED BAG. REMOVED & REPLACED THE CARGO FWD SMOKE DESDR SIMA20180221005Igniter · failedDURING TAXI, TRIED TO START THE NR 2 ENGINE, HAD A HUNG START, RAN THE CHECK LIST HAD GAS FUMES , RAN CHECK LIST AND RETURNED TO GATE. REMOVED AND REPLACED THE RT ENGINE IGNITOR A IAW AMM 74-24-01. OPS CHECKED GOOD, NO DEFECTS NOTED.SDR SIMA20180201006Light · inoperativeNR 2 EMERGENCY LIGHT STRIP INOPERATIVE. REMOVED AND REPLACED THE EMERGENCY LIGHT STRIP IAW AMM 33-50-12.SDR SIMA20180201005Connector · brokenNR 1 EMERGENCY LIGHT STRIP HAS A BROKEN CONNECTOR. INSTALLED A NEW CONNECTOR AND PIN IAW SWPM 20-21-00.SDR SIMA20180131003Light · damagedL5 EMERGENCY LIGHT STRIP DAMAGED. REMOVED AND REPLACED THE EMERGENCY LIGHT IAW AMM 33-50-12SDR SIMA20180131002Light · damagedR3 LIGHT STRIP IS DAMAGED. REMOVED AND REPLACED THE EMERGENCY LIGHT STRIP IAW AMM 33-50-12.SDR SIMA20180126011Brace · crackedNLG UPLOCK BOX AFT BRACE IS CRACKED. REMOVED AND REPLACED NLG UPLOCK BOX AFT BRACE IAW SRM 51-40-02.SDR SIMA20180124002Hinge Fitting · abnormalRT AILERON ACTUATOR HINGE FITTING LUG HOLE WORN BUSHING LOOSE IN LUG. REMOVED AND REPLACED RT AILERON ACTUATOR HINGE FITTING IAW SRM 51-40-02, EO EM-27MR-112.SDR SIMA20180124003Fitting · damagedRT AILERON DAMPER FITTING OUTBD LUG HOLE IS DAMAGED. REMOVED AND REPLACED RT AILERON DAMPER FITTING IAW SRM 51-40-02, EO EM-27MR-112.SDR SIMA20180123017Rib · crackedNOSE RIB ON LEFT ELEVATOR INBOARD HINGE CUTOUT INBOARD SIDE IS CRACKED. REMOVED AND REPLACED LT ELEVATOR NOSE RIB ON INBOARD HINGE CUTOUT INBOARD SIDE IAW SRM 51-40-02SDR SIMA20180123016Frame · crackedFRAME 10 CRACKED BELOW LT DV WINDOW CUTOUT. REMOVED AND REPLACED FRAME 10 BELOW LT DV WINDOW CUTOUT IAW SRM 51-40-02.SDR SIMA20180123015Fitting · corrodedSHEAR CLIP AT FRAME 65 IS CORRODED. PERFORMED REPAIR TO SHEAR CLIP AT FRAME 65 IAW SRM 53-31-04.SDR SIMA20180123014Fitting · damagedLT AILERON DAMPNER FITTING IS CHAFFED ON INNER SURFACE. REMOVED AND REPLACED LT AILERON DAMPER FITTING IAW EO EM-27MR-112.SDR SIMA20180123020Stringer · crackedSTRINGER 6R CRACKED AT FRAME 13. REMOVED AND REPLACED STR 6R AT FR 13 IAW SRM 51-40-02.SDR SIMA20180123012Door Sill · corrodedCARGO DOOR SILL IS CORRODED. REMOVED AND REPLACED THE CARGO DOOR SILL IAW SRM 51-40-02.SDR SIMA20180123018Door Sill · corrodedSERVICE DOOR CUTOUT LOWER CENTER SILL CORRODED. REMOVED AND REPLACED SERVICE DOOR CUTOUT LOWER CENTER SILL IAW SRM 51-40-02.SDR SIMA20180123019Frame · crackedFRAME 10 CRACKED BELOW RT DV WINDOW CUTOUT. REMOVED AND REPLACED FRAME 10 BELOW RT DV WINDOW CUTOUT IAW SRM 51-40-02SDR SIMA20180123013Frame · crackedFRAME 23 CRACKED BETWEEN STR 15R AND 16R. ACCOMPLISHED REPAIR OF FR 23 BETWEEN STR 15R-16R IAW SRM 53-00-04 ITEM 3 AND 51-40-02.SDR SIMA20180105004Structure · erodedTHE RT NR 2 LEADING EDGE ERODED, AND IS OUT OF LIMITS IN ONE AREA AT ZONE NR 2. REPAIRED DAMAGE IAW ERS EM-55MR-574SDR SIMA20171220007Floor Support · corrodedLEFT FLOOR SUPPORT HAS CORROSION BETWEEN FRAMES 23 AND 24. REPAIR THE FLOOR SUPPORT.SDR SIMA20171220008Floor Support · corrodedRIGHT FLOOR SUPPORT HAS CORROSION BETWEEN FRAMES 25 AND 26. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 51-40-02.SDR SIMA20171220006Crossbeam · crackedCENTER AISLE CARBON CROSSBEAM AT FRAME 27 IS CRACKED. REMOVED AND REPLACED THE CROSSBEAM CENTER AISLE IAW SRM 51-40-02.SDR SIMA20171220003Floor Support · crackedGALLEY LEFT FLOOR SUPPORT LT ANGLE BETWEEN FRAMES 16 AND 17 CRACKED. REMOVED AND REPLACED THE FLOOR SUPPORT ANGLE BETWEEN FRAMES 16 AND 17 IAW SRM 51-40-02.SDR SIMA20171220004Floorbeam · corrodedGALLEY CENTER AISLE FLOORBEAM AT FRAME 20 CORRODED. REMOVED AND REPLACED THE FLOORBEAM IAW SRM 53-21-10, AND ETN-EM-53-139R4.SDR SIMA20171220005Floor Support · crackedGALLEY CENTER FLOOR SUPPORT LT ANGLE BETWEEN FRAMES 16 AND 17 CRACKED. REMOVED AND REPLACEMENT THE FLOOR SUPPORT ANGLE IAW SRM 51-40-02.SDR SIMA20150222002Bracket · brokenREENTER MEL 25 - 53, AFT FLASHLIGHT BRACKET BROKEN. R & R FLASHLIGHT ASSEMBLY IAW AMM 33-50-16. OPERATIONS CHECKED GOOD. MEL 25-53 RESTORED.SDR SIMA20141228006Cradle · brokenCAPTAIN`S FLASHLIGHT CLIP ON THE MOUNT IS BROKEN. R & R CAPTAIN`S FLASHLIGHT CRADLE. OPERATIONS CHECKED GOOD IAW AMM 33-50-16.SDR SIMA20141201001Controller · faultyCOUPLED TO FIRST OFFICER`S SIDE, DURING CLIMB OUT SPEED SELECTOR KNOB WOULD NOT CHANGE SPEED INITIALLY. AFTER 2 MIN SPEED WAS ABLE TO BE CHANGED INTERMITTENTLY. R & R NR 2 DISPLAYS CONTROL PANEL IAW AMM 34-22-04. OPERATIONS CHECKED GOOD. ACFT IS RVSM ELIGISDR SIMA20141125010Circuit Card · failedUPON DEPARTURE ALT SPD & HDG SELECTORS BECAME INOPERATIVE. THE SELECTORS REMAINED INOPERATIVE UNTIL SHORT FINAL. DEFERRED IAW MEL 33-02. R & R NR 1 IC 600 IAW AMM 31-42-01. OPERATIONS CHECKED GOOD IAW 31-42-00 & 22-11-00 MEL 22-2 IS RESTORED.SDR SIMA20141004001Sign · fadedEMERGENCY EXIT SIGN ON MAIN CABIN DOOR FADED & ILLEGIBLE. R & R IAW AMM 11-00-01.SDR SIMA20141002006Valve · failedDURING CLIMB THROUGH 12,000 FEET, NR 2 PACK VALVE FAILED MESSAGE. R & R NR 2 PACK VALVE IAW AMM 21-51-01. OPS CHECKED GOOD. LEAK CHECKED GOOD.SDR SIMA20140615001Flashlight · inoperativeAFT CABIN FLASHLIGHT INOPERATIVE. R & R AFT CABIN FLASHLIGHT IAW AMM 33-50-16. OPS CHECKED GOOD.SDR SIMA20140430002Flashlight · brokenFIRST OFFICER'S EMERGENCY FLASHLIGHT IS BROKEN. R & R FIRST OFFICER'S EMERGENCY FLASHLIGHT IAW AMM 33-50-16, OPERATIONS CHECKED GOOD.SDR SIMA20140430004Cradle · damagedFORWARD PAX CABIN EMERGENCY LIGHT CRADLE STRUCTURE HAS EVIDENCE OF OVERHEATING. R & R FWD EMERGENCY LIGHT CHARGER CRADLE IAW AMM 33-50-16, OPERATIONS CHECKED GOOD.SDR SIMA20140430003Light · malfunctionedAFT PAX CABIN EMERGENCY LIGHT CRADLE STRUCTURE HAS EVIDENCE OF OVERHEATING. R & R AFT PAX EMERGENCY LIGHT ASSEMBLY IAW AMM 33-50-16, OPERATIONS CHECKED GOOD.SDR SIMA20140404002Wheel · failedJUST AFTER V1 NOSE SHIMMY THEN BUMP, BUMP, BUMP & THEN AIRBORNE. R & R LT NLG WHEEL ASSEMBLY IAW WC 32-700-17, OPERATIONS CHECKED GOOD.SDR SIMA20140112009Flashlight · inoperativeFLIGHT ATTENDANT`S FLASHLIGHT INOPERATIVE. R & R FLIGHT ATTENDANT`S FLASHLIGHT IAW AMM 33-51-01. OPERATIONS CHECKED GOOD, NO FURTHER DEFECTS NOTED.SDR SIMA20130921002Bulb · brokenCAPTAIN`S FLASHLIGHT BULB BROKEN. R & R FLASHLIGHT ASSY IAW AMM 33-50-00, OPS CHECKED GOOD.SDR SIMA20130726002Battery · inoperativeDURING MX INSPECTION, FOUND THE CAPTAIN’S FLASHLIGHT, RED LED TO CHARGING STATUS INOPERATIVE. ACFT REMOVED FROM SERVICE. R & R CAPTAIN’S FLASHLIGHT BATTERY IAW STANDARD PRACTICES. OPS CHECKED GOOD. ACFT RETURNED TO SERVICE.SDR SIMA20130721003Cradle · inoperativeAFT CABIN FLASHLIGHT CHARGING CRADLE INOPERATIVE. R & R AFT FLASHLIGHT CRADLE WITH SERVICEABLE ONE IAW AMM 33-50-16. NO OTHER DEFECTS NOTED AT THIS TIME.