N860DA
Service difficulty reports · 95
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N860DA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N860DA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR GIRA202609240001Bulkhead Web · ground damageRH WING DAMAGED BY COLLISION WITH ANOTHER AIRCRAFT. RH WING CLOSURE RIB AT OSAS 1428 DAMAGED. CORRECTIVE ACTION: CLOSURE RIB REPLACED BY BOEING AOG TEAM REF BOEING ASSIGNMENT NUMBER GF4-RE-BGS-2600806SDR DALA2020090322929Battery Pack · inoperativeEMERGENCY EXIT SIGN ABOVE FLIGHT ATTENDANT AT DOOR L1 IS INOPERATIVE. REPLACED EMERGENCY BATTERY POWER PACK AT L1. SYSTEM OPERATION IS NORMAL.SDR DALA2020072312632Battery · not seatedEMERGENCY LIGHTS AT R2 AREA INOPERATIVE. RESEATED BATTERY. SYSTEM OPERATION IS NORMAL.SDR DALA2020072312631Power Supply · inoperativeEMERGENCY LIGHTS AT L4 ARE INOPERATIVE. REPLACED BATTERY AND POWER SUPPLY. SYSTEM OPERATION IS NORMALSDR DALA2020070762552Lock · brokenAFT RIGHT ECONOMY CLASS INSEAT EMERGENCY LIGHTS ARE INOPERATIVE. FOUND BATTERY PACK CHARGER LOCK ON M33401 BROKEN. REPLACED CHARGER. SYSTEM OPERATION IS NORMAL.SDR HK0Y2020031300000Turbine Blades · brokenIT WAS REPORTED THAT DURING FLIGHT DL89 (14JAN2020), THE AIRCRAFT N860DA #2 ENGINE (S/N:51201) SUFFERED SURGE & HIGH N3 VIBRATION DURING CLIMB. CREW ELECTED AIR TURN BACK AND THE ENGINE WAS SENT TO HAESL FOR INVESTIGATION. UPON DISASSEMBLY, 1-OFF HPT BLADE WASSDR DALA2020022641424Battery Pack · inoperative(AIRCRAFT 7001, L/P 1499944) EMERGENCY LIGHTS INOP AT DOOR 4 LEFT. CORRECTIVE ACTION: REPLACED EMERGENCY BATTERY PACK - OPS CHECK GOOD.SDR DALA2020020630927Battery Pack · inoperative(AIRCRAFT 7001, L/P 1471773) DOOR 4 LEFT EMERGENCY LIGHTS INOP, CORRECTIVE ACTION: REPLACED BATTERY PER B777 AMM 33-53.SDR DALA2020011700549Engine · making metalATB - ON DEPARTURE, EXPERIENCED COMPRESSOR STALLS AT APPROX 7700 FT. COMPLIED WITH QRH ENGINE VIBES MAX 5.0. RETURNED TO LAX DUE TO RIGHT ENGINE COMPRESSOR STALL. CORRECTIVE ACTION: LAX INSPECTED ENGINE NR 2 AND FOUND METAL IN TAIL PIPE. ENGINE NR 2 CHANGE ACCSDR DALA2019121187236Wire Harness · not reported(AIRCRAFT 7001, L/P 1218713) REFERENCE LOG 1218709 WIRE BUNDLE W0800 REQUIRES REPLACEMENT AT NSV. CORRECTIVE ACTION: DEFER TO MONITOR ON LP 1218709. REPLACE AT NSV.SDR DALA2019020540749Seat Track · corroded(AIRCRAFT 7001, L/P 0928363) MTC TASK - CORROSION FOUND ON SEAT TRACK LBL 72 BETWEEN STA 1452 TO STA 1520 WHILE DOING CLOSET 3F-1L INSTALLATION MARKOUT. SEAT TRACK REPAIR CARRIED OUT AS PER B777-200 SRM 53-00-52 , FIG 202 REPAIR 3 WORK ACCOMPLISHED WITH ER/A 5SDR DALA2019012900670Oxygen Box · broken(AIRCRAFT 7001, L/P 0923076) MIDLIFE MOD - PSU OXY BOX ASSY AT SEAT 2BC FOUND BROKEN. WORKCARD RAISED IN ERROR.SDR DALA2019020180667Battery · discharged(AIRCRAFT 7001, L/P 0920387) MIDLIFE MOD - DOOR L2 EMERGENCY BATTERY M33096 FOUND VOLTAGE LOW. EMER BATT M33096 AT DR2L REMOVED AND REPLACED AS PER B777 AMM 33-51-06 AND OPS TEST CARRIED OUT AS PER B777 AMM 33-51-06 FOUND SATIS.SDR DALA2019020180666Light · cracked(AIRCRAFT 7001, L/P 0920396) MIDLIFE MOD - PROX EMER LTS AT AFT GLY AND OFCR FOUND CRACKED. PROXIMITY EMER LTS AT AFT GLY AND OFCR. REMOVED AND REPLACED AS PER B777 AMM 33-51-05. OPS TEST REFR TO WKCARD 2500-01815-08.SDR DALA2019020140664Floor Support · dented(AIRCRAFT 7001, L/P 0915215) AD EM-EO TASK - BULK CARGO AT LBL 25" STA 1916 ATTACHED FLOOR STRINGER SURFACE FOUND DENT. FLOOR STRINGER AT LBL 25", STA 1888 TO STA 1928, REPAIR CARRIED OUT AS PER B777-200 , SRM 53-70-53 , FIG 202, REPAIR 2.SDR DALA2019012200451Nut · damaged(AIRCRAFT 7001, L/P 0908454) AD EM-EO TASK - BULK CARGO FLOOR STRUCTURE AT STRUCTURE AT STA 1916 LBL FOUND 01EA ANCHORNUT DAMAGE. BULK CARGO FLOOR STRUCTURE AT STA 1916 LBL 01EA ANCHORNUT REMOVED AND REPLACED AS PER SRM 51-40-02.SDR DALA2019012200450Nut · damaged(AIRCRAFT 7001, L/P 0908446) AD EM-EO TASK - BULK CARGO FLOOR STRUCTURE AT STA 2050 LBL FOUND 01EA ANCHORNUT DAMAGE. BULK CARGO FLOOR STRUCTURE AT STA 2050 LBL 01EA ANCHORNUT. REMOVED AND REPLACED AS PER SRM 51-40-02.SDR DALA2018092405704Skin · damagedDAMAGE FOUND ON ARRIVAL. AFT CARGO DOOR OPENING SKIN EDGE DAMAGE 5/32 INCH DEEP. LOWER FWD CORNER 14 INCH ABOVE LOWER EDGE. BLENDED OUT DAMAGE IAW SRM 53-00-01 FIG 102 DETAIL B AND TABLE A. ALODINED BARE METAL AND RESTORED TOPCOAT.SDR DALA2018052103462Charger · malfunctionedEMERGENCY LIGHTS CIRCUIT BREAKER TRIPPED. REPLACED THE BATTERY AND CHARGER AT THE R2 DOOR IAW AMM 33-51.SDR DALA2018031901816Proximity Sensor · out of adjustSHIP STATUS MESSAGE IN CRUISE "DOOR FLIGHT LOCK 3L". ADJUSTED GAP ON FLIGHT LOCK PROX SENSORS IAW AMM 52-71 AND 52-11.SDR DALA2017121808733Battery Pack · inoperativeLEFT OVERHEAD EMERGENCY LIGHTS AT ROWS 35, 38, 40, 43 & THE L3 DOOR FWD EMERGENCY LIGHTED SIGN INOPERATIVE. REPLACED THE SIGN ASSEMBLY AT THE L3 DOOR. REPLACED THE BATTERY AT THE L3 DOOR. OPS CHECKED GOOD.SDR DALA2017102407779Lock · failedL3 DOOR LOCK STATUS MESSAGE. TESTED THE L3 DOOR FLT LOCK IAW MM 52-11, OPS NORMAL, NO HISTORY.SDR DALA2017081806287Lens · missingEMERGENCY LIGHT LENS MISSING AFT GALLEY ARE BETWEEN F/A SEAT. REPLACED LENS ASSY. CHECKED OK.SDR DALA2017080600208Power Supply · inoperativeEMERGENCY LIGHTS AT SEAT ROWS 10-12 INOPERATIVE. REPLACED EMERGENCY LIGHT POWER SUPPLY AND BATTERY PACK M33098.SDR DALA2017073105856Lens · detachedEXIT SIGN AT THE L2 DOOR FELL OFF. SECURED THE EXIT SIGN LENS.SDR DALA2017051503912Thrust Reverser · damagedNR 2 ENGINE OTBD THRUST REVERSER INNER LINER HAS AREA OF THERMAL DAMAGE.SDR DALA2017051403911Thrust Reverser · damagedNR 2 ENGINE INBD THRUST REVERSER HAS AREA OF THERMAL DAMAGE ON THE INNER LINER.SDR DALA2017051103772Stringer · corrodedCORROSION ON STRINGER 44L FROM BS 1916 TO 2200. REPAIRED IAW ERA 558298-14, REV ORIGINAL.SDR DALA2017051103771Skin · corrodedCORROSION ON FUSELAGE SKIN FROM BS 1874 TO 2033.5 BETWEEN STRINGERS 43 AND 44L. REPAIRED IAW ERA 558381-14, REV ORIGINAL.SDR DALA2017051103770Skin · damagedDAMAGE ON FUSELAGE SKIN AT BS 2022 BETWEEN STRINGERS 43 AND 44L. REPAIRED IAW SRM 53-00-01, REPAIR 7.SDR DALA2017051703969Support Frame · crackedNR 1 PYLON INNER DOOR SUPPORT IS CRACKED 10 INCHES AFT OF HYD CONNECTION. REPLACED THE SUPPORT FRAME IAW DWG 313W3550.SDR DALA2017040402726Battery Pack · separatedEMERGENCY LIGHTS INOPERATIVE SEAT 10-17 CENTER ROW BOTH SIDES. FOUND BATTERY PACK HAD SEPARATED FROM POWER SUPPLY. REINSTALLED, AND OPS CHECKED GOOD IAW AMM 33-51.SDR DALA2017032802512Door · damagedUPON ARRIVAL FROM HND, FOUND AFT CARGO DOOR AFT LOWER CORNER DAMAGED/BENT AND RIVET HEAD SHEARED. ACCOMPLISHED REWORK OF DAMAGE ON LOWER AFT CORNER OF AFT CARGO DOOR. REF SRM 52-30-01 FIG 102 SHT 1. DAMAGE DESCRIPTION (BEND AT AN EDGE) REWORK PER FLAG NOTE 5. SDR DALA2017032002225Light · unknownEMERGENCY FLOOR LIGHTING DAMAGED OR INOPERATIVE. REPLACE MISSING LIGHT LENS COVER.SDR DALA2017032002224Light · unknownEMERGENCY FLOOR LIGHTING DAMAGED OR INOPERATIVE / LOCATIONS: 406. REPLACED MISSING LIGHT LENS COVER.SDR DALA2017013000739Bulb · missingWHITE EMERGENCY LIGHT AT SEAT 10B, BULBS AND COVER ARE MISSING. REPLACED THE BULBS AND COVER AT SEAT 10B.SDR DALA2017011700412Fuse · blownDURING SVC FOUND EMERGENCY LIGHTS IN SEATS 10-12 AB INOP. REPLACED BLOWN FUSE ON EMERGENCY POWER SUPPLY M33098 IAW AMM 33-51.SDR DALA2017011700415Light · unknownEMERGENCY FLOOR LIGHTING DAMAGED OR INOPERATIVE. REPLACED EMERGENCY FLOOR LIGHT LENS PER AMM 33-51.SDR DALA2017011700414Light · unknownEMERGENCY FLOOR LIGHTING DAMAGED OR INOPERATIVE. REPLACED EMERGENCY FLOOR LIGHTING LENS PER AMM 33-51.SDR DALA2016050503690Oven · smokeCREW REPORTS OVEN 814 SMOKING. RAN OVEN; SMOKES. NOT ELECTRICAL. CLEANED OVEN, NO HELP. R & R OVEN IAW AMM 25-34, OPS CK NORMAL.SDR DALA2015122907745Battery Pack · inoperativeEMERGENCY LIGHTS IN CEILING ON LT SIDE FROM SEAT ROW 32, FWD INOPERATIVE BATTERY PACK AT L1 AND L2. REPLACED BATTERY PACK AND CHARGER AT L1 AND L2 IAW AMM.SDR DALA2015101606221Battery Pack · inoperativeLIGHTS FIRST CLASS LT SIDE INOPERATIVE. R & R BATTERY PACK IAW MM 33-51-06. OPS CHECKED OK.SDR DALA2015042902960Power Supply · inoperativeEMERGENCY LIGHTS INOPERATIVE ON SEATS, FROM ROW 29 TO ROW 43. REPLACED NR 4 FUSE IN POWER SUPPLY M33404 AND EMERGENCY LIGHTS TEST OK AMM 33-51-06/201. 1923682.SDR DALA2015011400296Fuse · failedEMERGENCY LIGHT INOPERATIVE ON SEAT ROWS 10-12 BOTH SIDES. REPLACED FUSE IN POWER SUPPLY.SDR DALA14024417001Control Lever · malfunctionedAT GEAR DOWN AMS RECEIVED A GEAR DISAGREE EICAS. BOTH MAINS INDICATED UP AND NOSE GEAR INDICATED DOWN. DISCONTINUED APPROACH WENT AROUND AND FOLLOWED CHECK LIST. ALT GEAR DOWN EXTENSION SUCCESSFUL - 3 GEAR DOWN INDICATIONS AND CONTINUED TO UNEVENTFUL LANDINSDR DALA13055787001Battery Pack · inoperativeEMERGENCY LIGHTS INOPERATIVE AT R1 DOOR INTERIOR AND EXTERIOR AND RT AISLE OF F/C CABIN. R & R BATTERY PACK M33094 IAW MM 33-51-06. OPS CHECKED GOOD, OK FOR SERVICE.SDR DALA13047177001Battery Pack · inoperativeDURING L3 DOOR SLIDE DEPLOYMENT EPAS SYS FAILED TO OPERATE. SYS TESTED IAW AMM 52-11-20. OPS CHECKED GOOD. REMOVED AND INSTALLED SERVICABLE EPAS RESERVIOR IAW AMM 52-11-22. OPS CHECKED GOOD. REPLACED EPAS RESERVOIR IAW AMM 52-11-22, PB 401 SYS TEST NOSDR DALA12001447001Fuse · inoperativeEMERGENCY LIGHT ARE INOPERATIVE AT ROWS 10 THRU 14. REPLACED POWER SUPPLY FUSES PER AMM 33-51-06-960. OPS CHECKED GOOD.SDR DALA2015010800143Skin · damagedDURING WALK AROUND, HOLES IN FUSELAGE IN BS 330, STRINGER 25.SDR DALA1220687001Battery · inoperativeDURING MAINTENANCE VISIT, THE 3L EPAS BATTERY WAS FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED THE BATTERY. SYSTEM OPERATION WAS NORMAL AFTER THE BATTERY WAS REPLACED.