N8612K
Service difficulty reports · 179
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N8612K' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N8612K' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2021031750530Support · corrodedAFT CABIN WET AREA STA 948; BL51R; WL208; INTERCOSTAL FLOOR SUPPORT ADJACENT TO LAV MOUNT FTG; CORROSION. / CORROSION FOUND TO BE OUT OF LIMITS PER SRM 53-70-51-1A-1 100% MATERIAL LOSS REMOVED AND REPLACED FLOOR SUPPORT FROM ST. 947 - 967 RBL 51 IAW DWG # 147ASDR SWAA2021031750528Support · corrodedAFT CABIN WET AREA STA 948; BL51L; WL208; INTERCOSTAL FLOOR SUPPORT ADJACENT TO LAV MOUNT; CORROSION. / CORROSION FOUND TO BE OUT OF LIMITS PER SRM 53-70-51-1A-1 (100% MATERIAL LOSS) REMOVED AND REPLACED INTERCOSTAL FLOOR SUPPORT FROM STA 947 TO 967 LBL 51 IAWSDR SWAA2021031750526Support · corrodedAFT CABIN WET AREA STA 947; BL24L; WL208; INTERCOSTAL FLOOR SUPPORT UPPER SURFACE; ADJACENT TO 947 FLOOR BEAM; CORROSION . / REMOVED AND REPLACED INTERCOSTAL FLOOR SUPPORT FROM STA - 927 TO 947 LBL 24 IAW DWG # 147A5400 REV - AND SRM 51-40-02-0G-0 CORROSION FOSDR SWAA2021031750525Floor Support · corrodedAFT CABIN WET AREA STA 947; BL51L; WL208; INTERCOSTAL FLOOR SUPPORT UPPER SURFACE; ADJACENT TO 947 FLOOR BEAM; CORROSION. CORROSION FOUND TO BE OUT OF LIMITS PER SRM 5370511A1 (100% MATERIAL LOSS) REMOVED AND REPLACED INTERCOSTAL FLOOR SUPPORT FROM STA. 927 94SDR SWAA2021031750521Floorboard · damagedAFT WET AREA FLOOR BOARD 242E FACE SHEET PLY PULLED OFF. REPAIRED AFT WET AREA FLOORBOARD 242E FACESHEET PLY PULLED OFF UPPER SURFACE IAW B737 SRM 5300502R1 AND B737 SRM 5300502R0 REPAIR GENERALSDR SWAA2021031750518Floorboard · damagedAFT WET AREA FLOOR BOARD 241ABF FACE SHEET PLY PULLED OFF. REPAIRED AFT WET FLOORBOARD 352ABF UPPER FACESHEET IAW B737 SRM 5300502R1 AND B737 SRM 5300502R0SDR SWAA2021031750517Floorboard · damagedAFT WET AREA FLOOR BOARD 241D FACE SHEET PLY PULLED OFF. REPAIRED WET AREA FLOORBOARD 241D UPPER FACESHEET IAW B737 SRM 5300502R1 AND B737 SRM 5300502R0SDR SWAA2021031750516Floorboard · pulledAFT WET AREA FLOOR BOARD 242D FACE SHEET PLY PULLED OFF. REPAIRED AFT WET AREA FLOORBOARD 242D FACESHEET PLY PULLED OFF ON UPPER SURFACE IAW B737 SRM 5300502R1 AND B737 SRM 5300502R0 REPAIR GENERALSDR SWAA2021031750522Floorboard · damagedAFT WET AREA FLOOR BOARD 241E FACE SHEET PLY PULLED OFF. REPAIRED DAMAGED FACESHEET ON UPPER SURFACE OF FLOORBOARD 241E IAW 737800 SRM 5300502R0 REV. 71 REPAIR GENERAL AND SRM 5300502R1 REV. 71 REPAIR 1. TAP TEST GOODSDR SWAA2021031750515Floorboard · damagedAFT WET AREA FLOOR BOARD 242SF FACE SHEET PLY PULLED OFF. REPAIRED AREA'S OF FRAYED FIBERS ON UPPER SURFACE OF PANEL 242SF; IAW B737 SRM 5300502R1; SRM 5300502R0SDR SWAA2021031750514Floorboard · damagedAFT WET AREA FLOOR BOARD 242RF FACE SHEET PLY PULLED OFF. REPAIRED AND INSTALLED 2EA INSERTS ON AFT WET AREA FLOORBOARD 242RF FACE SHEET PLY PULLED OFF IAW B737 SRM 5300502R1 AND B737 SRM 5300502R0 REPAIR GENERAL A72547 A08792 A94665 A65224 A27992SDR SWAA2021031750524Floorboard · damagedAFT WET AREA FLOOR BOARD 242UF FACE SHEET PLY PULLED OFF. REPAIRED AND INSTALLED 8EA INSERTS ON AFT WET AREA FLOORBOARD 242UF FACESHEET PLY PULLED OFF IAW B737 SRM 5300502R1 AND B737 SRM 5300502R0 REPAIR GENERAL A72547 A18755 A93108 A89382 A95084 A73848 A61379SDR SWAA2021031750523Floorboard · damagedAFT WET AREA FLOOR BOARD 241AAF FACE SHEET PLY PULLED OFF / REPAIRED AFT WET AREA FLOOR BOARD 241AAF FACESHEET IAW B737 SRM 53-00-50-2R-1 AND 53-00-50-2R-0SDR SWAA2021031950372Strap · corrodedAFT CARGO COMP.FLOOR PANEL STRAP AT 727D CORRODED AROUND MID FASTNER HOLE / REPLACED ON PRT RACK WITH NEW PART AFT CARGO FLOOR PNL STRAP AT 727D IAW BOEING DOC 146A7500; REV: - A21591SDR SWAA2021031950379Web · corrodedAFT CARGO COMP.AFT CARGO DOOR SURROUND BOTTOM WEB CORRODED AROUND FASTNER HOLES / REMOVED CORROSION AT AFT CARGO (SILL WEB) DOOR SURROUND BOTTOM WEB IAW SRM 51-10-02-0G-0 ITEM 15. ORIGINAL 'T' .050 REMAINING .038 LOSS .012 FOUND TO BE OUT OF LIMITS IAW B737 SRSDR SWAA2021031750377Angle · corrodedAFT CARGO COMP.RH ZANGLE CORRODED AROUND FASTNER HOLES STA.727H+10767 RBL 22' WL158. REMOVED CORROSION; VERIFIED USING 10X MAG GLASS. EVALUATED DAMAGE AS MATERIAL LOSS OF 0.01' ORIGINAL (T) 0.04 REMAINING (T) 0.03' OUT OF LIMITS IAW SRM 5300531A2. REMOVED Z-ANSDR SWAA2021031950345Floor Panel · corrodedAFT CARGO PIT; PNL140EF CORRODED ALONG EDGE. / EVALUATED CORROSION ALONG EDGE OF AFT CARGO PIT PNL 140EF; FOUND THE TOTAL ACCUMULATED DAMAGE LENGTH TO BE MORE THAN THE 20' MAX ALLOWED - OUT OF LIMITS IAW SRM 53-00-53-1A-1; FABRICATED NEW PNL 140EF IAW AMM 25-5SDR SWAA2021031950347Floor Panel · corrodedAFT CARGO PIT; PNL 140CF IS CORRODED AT THRESHOLD AREAS. / CORROSION LENGTH OF 27' FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1 MAX ALLOWED IS 10' LENGTH FABRICATED AND VERIFIED MATERIAL IAW AMM 25-52-01-201-801 AND DRW 453A2610-18 REV D SHEET 2; TREATED ANSDR SWAA2021031950349Plate · corrodedAFT CARGO PIT; THRESHOLD FLOOR PLATE CORRODED.MARKED / REPLACED ON RACK WITH NEW PARTS AFT CARGO PIT THRESHOLD FLOOR PLATES IAW AIPC 25-52-10-04 A68085 AND E30461SDR SWAA2021031950355Angle · corrodedFWD CARGO COMPARTMENT - FLOOR Z-ANGLE CORRODED - BS500A - 500I; RBL24; WL156 / REMOVED CORROSION AT FWD CARGO CMM60 COMPARTMENT FLOOR Z-ANGLE. STA-500A-500I RBL 24 IAW B737 SRM 51-10-02-06-0 ITEM IS. ORIGINAL 'T: .040 REMAINGING .029 LOSS .011 FOUND TO BE OUT SDR SWAA2021031950356Cap · corrodedAFT CARGO RH #3 Z-ANGLE CAP STRIP BOTTOM CORRODED / VERIFIED P/N 453A26-11 FOR AFT CARGO PIT RH #3 Z-ANGLE CAP STRIP IAW DRW 453A2600 SHEET 93 REV A ATAG - A21590SDR SWAA2021031850364Panel · crackedWING TO BODY PANEL 194GR - CRACKING AT FASTENER HOLE / REPIARED DAMAGE TO FASTENER HOLE ON PANEL 194GR IAW 737-800 SRM'S 53-60-70-2R-1 REV. 71 TABLE 202; SRM 51-70-04-2R-1 REV. 71 REPAIR 1 AND SRM 51-70-04-2R-0 REV. 71. TAP TEST GOOD. RESTORED FINISH IAW B737 SDR SWAA2021031750354Angle · corrodedFWD CARGO COMPARTMENT FLOOR Z ANGLE CORRODED BS500 500I; LBL24; WL156. REMOVED CORROSION FWD CARGO COMPARTMENT FLOOR Z ANGLE STA 500 500I LBL 24 IAW B737 SRM 5110020G0 ITEM 15. ORIGINAL 'T': .040 REMAINGING .027 LOSS .013 FOUND TO BE OUT OF LIMITS IAW B737 SRSDR SWAA2021031750339Floor Panel · corrodedFORWARD CARGO COMPARTMENT FLOOR PANEL 120DF HAS CORROSION / REPLACED FWD CARGO COMPT. FLOOR PANEL 120DF; VERIFIED MATERIAL AS .071; 2024 T-3; FABRICATED NEW PANEL IAW AMM 25-52-01; AND BOEING DO 453A1610-20 REV: F. TREATED BACK SIDE OF PANEL IAW AMM 51-21-41; SDR SWAA2021031750346Floor Panel · corrodedAFT CARGO PIT; PNL 140AF HAS LIGHT CORROSION ALONG EDGES. / REPLACED AFT CARGO PIT PNL 140AF. VERIFIED MATERIAL AS 2024 T-3; .071 ATAG # A05897; FABRICATED NEW PANEL IAW AMM 25-52-01 AND BOEING DOC'S 453A2610 REV: D & E TREATED BACK OF PANEL IAW AMM 51-21-41. SDR SWAA2021031750340Floor Panel · corrodedFORWARD CARGO COMPARTMENT FLOOR PANEL 120CF HAS CORROSION / REPLACED FWD CARGO COMPT FLOOR PANEL 120CF; VERIFIED MATERIAL AS .071 2024 T-3; ATAG #A05895. FABRICATED NEW PANEL IAW DRW 453A1610-103; REV: A. TREATED BACK OF PANEL IAW AMM 51-21-41. PRIMED BACK OF SDR SWAA2021031750351Web · corrodedFORWARD CARGO COMPARTMENT AT CARGO DOOR OPENING; WEB UNDER THRESHOLD HAS CORROSION (BS 440 TO 480; STR 25R AND WL141) / EVALUATED CORROSION WEB AT FWD CARGO DOOR OPENING UNDER THRESHOLD FOUND 100% MATERIAL LOSS FOUND OUT OF LIMITS I-A-W SRM 51-10-02-0G-0. REMOSDR SWAA2021031743847Web · crackedCENTER WING REAR SPAR VAPOR WEB HAS A CRACK AT RBL 31.83. THE CRACK IS 5' LONG AND EXTENDS DIAGONALLY DOWNWARD AND ENDS AT A FASTENER AT RBL 34.83 REPAIRED PER SRM 57-10-10-2R-2 REPAIR 2 PAR 6 THIS IS A TIME LIMITED REPAIR TO PERFORM A DVI EVERY 3000 FLIGHT CYSDR SWAA2021031743848Barrier · crackedRIGHT MLG WHEEL WELL; AFT SPAR VAPOR BARRIER CRACKED FROM RBL 31.83 TO RBL 34.83.5' DIAGONAL CRACK (10' FROM BOTTOM OF VAPOR BARRIER)PERFORMED INTERIM REPAIR IAW SRM 57-10-10. DO A VISUAL INSPECTION OF THE REPAIR AREA AT 1200 FLIGHT CYCLE INTERVALS OR MORE FRESDR SWAA2021031743849Barrier · crackedRIGHT MLG WHEEL WELL; AFT SPAR VAPOR BARRIER CRACKED FROM RBL 29 TO RBL 31.83 1.75' DIAGONAL CRACK ( 14' FROM BOTTOM OF VAPOR BARRIER)PERFORMED INTERIM REPAIR IAW SRM 57-10-10. DO A VISUAL INSPECTION OF THE REPAIR AREA AT 1200 FLIGHT CYCLE INTERVALS OR MORE FRSDR SWAA2021081202925Radome · damagedDAMAGE TO RADOME DISCOVERED BY GROUND CREW DURING PREFLIGHT INSPECTION. / REMOVED & REPLACED NOSE ASSY PER AMM 53-52-00#1035140P/N OFF 1001002-1 P/N ON 1001002-7BS/N OFF 0108011C S/N ON 0212061SDR SWAA2020072000035Barrier · crackedRIGHT MLG WHEEL WELL; AFT SPAR VAPOR BARRIER CRACKED FROM RBL 31.83 TO RBL 34.83.5' DIAGONAL CRACK (10' FROM BOTTOM OF VAPOR BARRIER)PERFORMED INTERIM REPAIR IAW SRM 57-10-10. DO A VISUAL INSPECTION OF THE REPAIR AREA AT 1200 FLIGHT CYCLE INTERVALS OR MORE FRESDR SWAA2020072000034Barrier · crackedRIGHT MLG WHEEL WELL; AFT SPAR VAPOR BARRIER CRACKED FROM RBL 29 TO RBL 31.83 1.75' DIAGONAL CRACK ( 14' FROM BOTTOM OF VAPOR BARRIER)PERFORMED INTERIM REPAIR IAW SRM 57-10-10. DO A VISUAL INSPECTION OF THE REPAIR AREA AT 1200 FLIGHT CYCLE INTERVALS OR MORE FRSDR SWAA2020050775866Battery Pack · dischargedSEVERAL EMERGENCY EXIT LIGHTS INOP / R/R'D BATTERY PACKS @ RH AFT;RH STA 727C & 13; FWD RH & FWD L/H OPS CK GOOD PER AMM 33-51-06SDR SWAA2022031445811Seal · crackedLT HORIZ STAB UPPER FWD SLIDING SEAL CRACKED / R7R LH HORIZ STAB UPPER FWD SLIDING SEAL IAW AMM 53-31-31INSP 43511SDR SWAA2022031445812Seal · crackedRT HORIZ STAB UPPER FWD SLIDING SEAL CRACKED / R&R RH HORIZ STAB UPPER FWD SLIDING SEAL IAW AMM 53-31-31INSP 43511SDR SWAA2022030445934Strip · crackedAFT CARGO ATTACH CAP STRIP FOR FLOOR PANEL 140AF CRACKED / RECEIVED NEW CAP STRIP FOR AFT CARGO FLOOR PANEL 140AF P/N 453A2611-12 A TAG # A33577 IAW AIC 25-52-10-02 IT. 35SDR SWAA2022030445932Angle · crackedL/H WING T/E WEB I/B OF DEFLECTION RIB CRACKED / REMOVED + REPLACED ANGLE L/H WING T/E I/B OF DEFLECTION RIB IAW SRM 51-40-02-0G-0; 51-40-05-0G-0; DWG 115A2512 SHT 16 REV -SDR SWAA2019032731100Angle · crackedLT WING TRAILING EDGE WEB INBOARD OF DEFLECTION RIB CRACKED. R&R ANGLE IAW SRM & DWG.SDR SWAA2022022245909Plate · crackedR/H WING; TRAILING EDGE; UNDER BOTTOM PANEL 651EB; I/B WAFFLE PLATE; CRACKED AT O/B FASTENER / REMOVED & REPLACED R/H WING; TRAILING EDGE; UNDER BOTTOM PANEL 651EB; I/B WAFFLE PLATE IAW SRM 51-40-02-0G-0; 51-40-05-0G-0; AMM 51-21-99-300-801 & AIPC 57-50-00-22ASDR SWAA2019032631077Plate · crackedRT WING TRAILING EDGE UNDER BOTTOM PANEL 651EB INBOARD WAFFLE PLATE CRACKED AT OUTBOARD FASTENER. R&R WAFFLE PLATE IAW SRM.SDR SWAA2022030445855Floor Panel · corrodedAFT CARGO PIT PANEL 140CF HAS CORROSION AROUND EDGES / AFT CARGO PIT PANEL 140CF REPLACED WITH NEW AFT CARGO PIT PANEL 140CF; P/N 453A2610-18 DUE TO ALLOWABLE DAMAGE BEING OUT OF LIMITS; TOTAL ACCUMULATED CORROSION DAMAGE LENGTH OVER 20 INCHES; PER SRM 53-000-SDR SWAA2022030445856Floor Panel · corrodedAFT CARGO PIT PANEL 140AF HAS CORROSION AROUND EDGES / REPLACED WITH A NEW PANEL 140AF; P/N 453A2610-38 A TAG WN2992 I/A/W AIPC 25-52-10-19 ITEM 5 AND BOEING DRAWING 453A2610 REV E. CORROSION DAMAGE LENGTH IS MORE THAN 20 INCHES; OUT OF LIMITS PER SRM 53-0-053SDR SWAA2022030445857Floor Panel · corrodedAFT CARGO PIT PANEL 140BF HAS CORROSION AROUND EDGES / AFT CARGO PIT PANEL 140BF REPLACED WITH NEW AFT CARGO PIT PANEL IAW IPC 25-52-10-19 DUE TO OUT OF LIMITS FOR ALLOWABLE DAMAGE; TOTAL ACCUMULATED DAMAGE LENGTH MORE THAN 20 INCHES IAW SRM 53-00-53-1A-1 FOUNSDR SWAA2022030445865Floor Panel · corrodedFWD CARGO PIT PANEL 120DF HAS CORROSION AT EDGES / FWD CARGO PANEL 120DF CORROSION AT EDGES EXCEEDED ALLOWABLE LIMITS OF COMBINED 20 INCH TOTAL IAW SRM 53-00-53-1A-1 FIG 102. REPLACED FLOOR PANEL 120DF PART NO 453A1610-20 IAW AIPC 25-52-10-17 & BOEING DWG PL 4SDR SWAA2022030445868Floor Panel · corrodedFWD CARGO PIT PANEL 120AF HAS CRROSION AT EDGES / FWD CARGO FLOOR PANEL 120AF CORROSION AT EDGES EXCEEDED ALLOWABLE LIMITS OF COMBINED 20 INCH TOTAL IAW SRM 53-00-53-1A-1 FIG 102. REPLACED FLOOR PANEL 120AF PART NO 453A1610-14 IAW AIPC 25-52-10-17 AND BOEING DSDR SWAA2022030445871None · crackedFWD CARGO AT BS 500I S26RH STRINGER CLIP CRACKED. / REMOVED AND REPLACED FWD CARGO BS 500I STR 26R STRINGER CLIP IAW B737 SRM 51-40-02-0G0 PARA 4; DWG 143A1234 ID:0014 REV A.SDR SWAA2022030445873Angle · corrodedFWD CARGO AT BS 500I AFT BLKD LOWER SUPPORT ANGLE CORRODED LBL22. / REMOVED AND REPLACED FWD CARGO BULKLHEAD LOWER SUPPORT ANGLE BS 500I LBL22. FOUND TO BE OUT OF LIMITS NO WRITTEN LIMITS. IAW B737 SRM 51-40-02-0G-0 PARA 4;DWG 143A9481 ID 0017 REV-.SDR SWAA2022030445874Gusset · crackedFWD CARGO AT BS 500I GUSSET CRACKED AT S19RH. / REMOVED AND REPLACED GUSSET AT FWD CARGO AT B.S. 500I STR 19RH; P/N 143A7902 ATAG A30211 IAW B737-700 DWG 143A7902 REV B AND SRM 51-40-02-0G-0SDR SWAA2022030445878None · crackedFWD CARGO AT BS 500I S26LH STRINGER CLIP CRACKED. / REMOVED & REPLACED STRCLIP FWD CARGO AT BS 500I 25L IAW SRM 51-40-02-0G-0; 51-40-05-0G-0; & DWG 143A1234 SHT 14 REV A
Back to N8612K