N862DA
Service difficulty reports · 88
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N862DA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N862DA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2020090322931Pseu · malfunctionedR2 DOOR INDICATES OPEN. REPLACED PSEU.SDR DALA2020083102896Plug · missingCARGO COVERSION SEVERAL AIR RETURN GRILL PLUGS MISSING. C/W ERA 586747-14.SDR DALA2020051102381Connector · brokenSHIP 7003 - IFSD - PASSING 10K FEET ON CLIMB OUT, LEFT ENGINE OVERHEAT EICAS MESSAGE APPEARED. THE FLIGHT CREW FOLLOWED QRH PROCEDURE AND SHUT THE LEFT ENGINE DOWN. THE FLIGHT CONTINUED TO ATL. CORRECTIVE ACTION: FOUND BROKEN CONNECTOR END ON #1 ENGINE RIGHT CSDR DALA2020031001747Charger · inoperative(AIRCRAFT 7003, L/P 7200250) COMFORT CABIN EMERGENCY LIGHTS STAYS ON LOC 31 TO 40 AND DOOR 3L FWD EMERGENCY SIGN. CORRECTIVE ACTION: REMOVED AND REPLACED BATTERY CHARGER ASSY EIN M9368 PER B777 AMM 33-51.SDR DALA2020021801225Lamp · inoperative(AIRCRAFT 7003, L/P 6432173) DOOR R3 EXT SLIDE/OVERWING LIGHT OUT. CORRECTIVE ACTION: RELAMPED R3 EXT SLIDE/OVERWING LIGHT & CKD OK PER B777 AMM 33-51-04.SDR DALA2020021801224Lamp · inoperative(AIRCRAFT 7003, L/P 6432172) DOOR L1 EXT SLIDE/OVERWING LIGHT OUT. CORRECTIVE ACTION: RELAMPED L1 EXT SLIDE/OVERWING LIGHT & CKD OK PER B777 AMM 33-51-04.SDR DALA2019123007607Warning Message · false activationDOOR FLIGHT LOCK 1R STATUS MESSAGE. CORRECTIVE MESSAGE: PERFORMED FUNCTIONAL CHECK OF FLIGHT DECK DOOR LOCK PER AMM 52-51.SDR DALA2019112206840Skin · cracked(AIRCRAFT 7003, L/P 1370313) CRACK IN 3RD FASTENER HOLE BELOW EXISTING REPAIR ON #8 SLAT. CORRECTIVE ACTION: REPAIRED PER B777 SRM 57-43-01, REPAIR 15 REF LOG 0931346.SDR DALA2019111306618Power Supply · failed(AIRCRAFT 7003, L/P 1352478) WHILE PERFORMING SVC CHK, FOUND EMERGENCY LIGHTS @ SEAT ROWS 31 DEF THROUGH 40 DEF WOULD NOT GO OUT. ALSO, CEILING LIGHTS WOULD NOT COME ON. CORRECTIVE ACTION: T/S PER B777 FRM FIM 33-51-805. FOUND POWER SUPPLY M9368 BAD (SEAT ROWSSDR DALA201910306272Connector · disconnected(AIRCRAFT 7003, L/P 6603924) EMERGENCY PATHWAY LIGHT AT 4C IS INOP. CORRECTIVE ACTION: FOUND ELECTRIC CONNECTOR DISCONNECTED. RECONNECTED CONNECTOR. OPS CHECK OK.SDR DALA2019070104271Lens · broken(AIRCRAFT 7003, L/P 1145670) DOOR 2 RIGHT EXTERIOR DOOR EMERGENCY LIGHT LENS BROKEN. REPLACED LENS ASSY.SDR DALA20190402099Charger · inoperativeDOOR 1 LEFT EMERGENCY SLIDE LIGHT INOP. REPLACED CHARGER PER AMM 33-51.SDR DALA2019021100968Switch · failed(AIRCRAFT 7003, L/P 0934139) DUE TO CONFIRMED REPORTS OF EMERGENCY LIGHTS ILLUMINATING AT 4L PED WITH EMERGENCY LIGHT SW ON P5 ARMED AND 4L DOOR MODE SELECT HANDLE IN DISARMED POSITION AND DOOR HANDLE TO THE FULL OPEN POSITION. CHECKED DOOR RIGGING OF PROX ANDSDR DALA2019020100674Light · malfunctioned(AIRCRAFT 7003, L/P 5187561) MAINTENANCE RECEIVED VERBAL REPORT FROM CLEANING CREW THAT DOOR 4L EMERGENCY LIGHTS WERE ON DURING DOOR OPEN. UPON ENTERING DOOR 4L LOCATION, FOUND EMERGENCY LIGHTS NOT ILLUMINATED. PERFORMED OPERATIONAL TEST OF LIGHTS AS PER B777 SDR DALA2018122107332Seat Track · corroded(AIRCRAFT 7003, L/P 0872603) CABIN R3 DOOR AREA SEAT TRACK FROM STA 1455-1495 RBL=75 FOUND CORRODED AS MARKED. CABIN R3 DOOR AREA BET STA 1445-STA 1557 AT RBL 75 ATTACHED CORRODED SEAT TRACK REMOVED AND REPAIRED WITH NEW SEAT TRACK SECTION AS PER DELTA ER/A 53SDR DALA2018112986883Fitting · fod(AIRCRAFT 7003, L/P 5235350) UNABLE TO ARM DOOR 4L. REMOVED DEBRIS FROM FITTINGS, CYCLED DOOR. OPS CKS GOOD. A/C OK / FOR SERVICE.SDR DALA2018110606464Light · damagedEMERGENCY FLOOR LIGHTING DAMAGED OR INOPERATIVE / LOCATIONS:11C / INTERIOR. REPLACED MISSING EMERGENCY LIGHT LENS.SDR DALA2018110606463Light · damagedEMERGENCY FLOOR LIGHTING DAMAGED OR INOPERATIVE / LOCATIONS:10C / INTERIOR. REPLACED MISSING EMERGENCY LIGHT LENS.SDR DALA2018110606462Light · damagedEMERGENCY FLOOR LIGHTING DAMAGED OR INOPERATIVE / LOCATIONS:11B / INTERIOR. REPLACED MISSING EMERGENCY LIGHT LENS.SDR DALA2018072704720Lens · missingEMERGENCY LIGHTS AT SEATS 3C & 11B MISSING LENSES. REPLACED MISSING LENSES.SDR DALA2018070904428Skin · damagedFOUND ON ARRIVAL, DAMAGE TO LOWER AFT CORNER OF R1 DOOR. FOUND DAMAGE TO EDGE OF OUTER DOOR SKIN LWR AFT CORNER FROM EDGE INWARD .250 IN .375 WIDE REPAIRED IAW SRM 52-10-01 BLENDED AFFECTED AREA CONVERSION COAT AND TOP COAT APPLIED.SDR DALA2018032601949Oxygen Mask · failedCAPTAIN`S OXYGEN MASK HAS LEAK IN THE HARNESS. THE HARNESS WILL NOT INFLATE. REPLACED THE CAPTAIN`S OXYGEN MASK. LEAK CHECKED GOOD IAW AMM 35-11.SDR DALA2017122608881Warning Light · false activationR1 DOOR FLIGHT LOCK STATUS MESSAGE ON LANDING . CYCLED THE R1 DOOR OPEN AND CLOSED. TROUBLESHOT IAW FIM 52-11-00-810-807. OPS CHECKED NORMAL. MESSAGE CLEARED. OK FOR SERVICE.SDR DALA2017060104431Circuit Breaker · malfunctionedEMERGENCY LIGHTS INTERMITTENTLY ON AND OFF BEFORE TAKEOFF AND LANDING. T/S PER SRM 33-51-06 RESET C/B ON P11 PANEL AND OPS CHECK PER AMM 33-51.SDR DALA2017031702178Power Supply · inoperativeEMERGENCY LIGHTS BY THE L4 DOOR AND GOING UP AISLE ARE INOPERATIVE. REMOVED AND REPLACED POWER SUPPLY (M33407) AND BATTERY PACK IAW AMM 33-51-06.SDR DALA2017030601840Angle · corrodedDURING LT PYLON INSPECTION, FOUND CORROSION ON LOWER SURFACE OF THE RIGHT ANGLE AT NACELLE STATION 454.6. REPLACED THE ANGLE IAW SRM 54-52.SDR DALA2017030601839Angle · corrodedDURING LT PYLON INSPECTION, FOUND CORROSION ON LOWER SURFACE OF LEFT ANGLE AT NACELLE STATION 454.6. REPLACED ANGLE IAW SRM 54-52.SDR DALA2017030601838Web · corrodedDURING LEFT PYLON INSPECTION FOUND CORROSION ON LOWER SURFACE OF WEB AT NACELLE STATION 454.6. REPLACED THE WEB IAW SRM 54-52.SDR DALA2017022101414Lens · missingRED EXIT ROW LIGHTS MISSING ON FLOOR IN FRONT OF L4 AND R4 DOORS. SECURED THE COVERS. LIGHT OPS NORMAL IAW AMM 33-51.SDR DALA2016111408774Battery Pack · inoperativeEMERGENCY LIGHTS SEAT ROWS 10-12 LT AND RT INOPERATIVE. R & R BATTERY PACK AND POWER SUPPLY IAW MM 33-51-06. OPS CHECKED GOOD.SDR DALA2015101106146Seat Track · chafedSEAT TRACK INBD & OTBD FLANGES BS 1035-1287 & RBL 11 FOUND WITH CHAFED. REPAIRED IAW PRI 539368-14, REV 0, REV 1, REV 2, ADVANCE PRI 539368-14, REV 0, REV 1, REV 2.SDR DALA2015100106150Seat Track · chafedCABIN SEAT TRACK INBD & OTBD FLANGES BS 1035-1287, LBL 11 FOUND CHAFED. REPAIRED THE SEAT TRACK IAW ERA 539368-14, PRI REV 0, REV 1 AND REV 2.SDR DALA2015100106151Seat Track · chafedCABIN SEAT TRACK INBD & OTBD FLANGE'S AT BS 1035-1287 & RBL 11 FOUND WITH CHAFED. REPAIRED THE SEAT TRACK IAW ERA 539368-14, PRI REV 0, REV 1 AND REV 2.SDR DALA2015093006149Seat Track · chafedCABIN SEAT TRACK INBD & OTBD FLANGES BS 1035-1287 & LBL 33 FOUND WITH CHAFED. REPAIRED THE SEAT TRACK IAW ERA 539368-14, PRI REV 0 AND REV 1.SDR DALA2015093006148Seat Track · chafedCABIN SEAT TRACK INBD & OTBD FLANGES BS 1035-1287 & RBL 33 FOUND CHAFED. REPAIRED THE SEAT TRACK IAW ERA 539368-14, PRI REV 0 AND REV 1.SDR DALA13072437003Battery Pack · inoperativeR4 DOOR EPAS BATTERY PACK NO ARM LIGHT. R & R BATTERY PACK IAW AMM 52-11-20. OPS CHECKED GOOD, OK FOR SERVICE.SDR DALA13022197003Reservoir · out of toleranceWHILE PERFORMING SERVICE CHECK, FOUND L1 DOOR EMERGENCY POWER ASSIST RESERVOIR OUT GREEN BAND. REPLACED RESERVOIR IAW AMM 52-11.SDR DALA12004537003Power Supply · inoperativeEMERGENCY LIGHTS AT ROWS 12, 13, 14 DO NOT WORK. REPLACED POWER SUPPLY PER AMM 33-52. OPS CHECKED GOOD.SDR DALA12003537003Battery Pack · inoperativeDURING SERVICE CHECK, EMERGENCY ESCAPE PATH LIGHTS FAILED TEST AT ROWS 10 THRU 14. REPLACED BATTERY SUPPLY M33098 AS PER AMM 33-51-06-960-802. OPS CHECKED GOOD.SDR DALA12002277003Battery Pack · inoperativeEMERGENCY LIGHTS AT SEAT ROWS 10 THRU 14 ONLY CAME ON FOR 3 SECONDS DURING TEST. REPLACED BATTERY PACK (M33098) PER MM33-51-06.SDR DALA1214067003Battery · dischargedDURING A MAINTENANCE VISIT, THE 2L EPAS BATTERY WAS FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED THE BATTERY. SYSTEM OPERATION WAS NORMAL AFTER THE BATTERY WAS REPLACED.SDR DALA1212797003Wire · exposedDURING A MAINTENANCE VISIT, THE EMERGENCY FLOOR LIGHTING WIRES WERE EXPOSED AT DOOR 3L BULKHEAD. MAINTENANCE REPAIRED THE EMERGENCY FLOOR LIGHTING PER BSWP CHAP 20. OP CKS GOOD PER B777-200ER. (2012-D0227)SDR DALA1208587003Wire · looseEMERGENCY EXIT LIGHT ON CROSS OVER AISLE BETWEEN DOORS 3L AND 3R POPPED OUT OF BULKHEAD WITH LOOSE WIRES. RE-TERMINATED WIRE. RESTOWED, OPS CHECK GOOD PER B777 AMM20-20.SDR DALA1208187003Charger · inoperativeDURING A MAINTENANCE VISIT, THE EMERGENCY LIGHTS AT SEATS 10BC TO 13BC WERE FOUND TO BE INOPERATIVE. MAINTENANCE FOUND THE BATTERY CHARGER AT 2R AFT INOPERATIVE AND REPLACED IT. SYSTEM OPERATION WAS NORMAL AFTER THE BATTERY CHARGER WAS REPLACED.SDR DALA1171347003Power Supply · inoperativeMAINTENANCE FOUND B ZONE EMERGENCY LIGHTS INOP. POWER SUPPLY REMOVED AND REPLACED PER AMM 33-51-06.SDR DALA1169767003Light · inoperativeDURING A MAINTENANCE VISIT, THE EMERGENCY FLOOR PROXIMITY LIGHT AT SEAT 13C WAS FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED THE PROXIMITY LIGHT ASSEMBLY. SYSTEM OPERATION WAS NORMAL AFTER THE LIGHT ASSEMBLY WAS REPLACED.SDR DL777100046Engine · making metalINBD WRITEUP OF RT ENG VIB MONITOR MESSAGE. PEFORMAMCE PAGE SHOW HIGH N2 VIBS THEN N2 VIBS DECREASED AND N1 VIBS INCREASED WITH OIL QTY DROP. FOUND METAL ON MCD AND IGB CHIP DETECTOR PORT. NR 2 ENG CHANGE IN PROGRESS. ETOPS CATEGORY 'F': ANY OTHER EVENT DETRSDR DL777091053Jettison System · malfunctioned3HRS IN FLT, FUEL DROPPED 13600LBS. FUEL DISAGREE EICAS. RAN FUEL DISAGREE AND FUEL LEAK CHECKLIST. TALKED TO ATL MX CYCLED FUEL JETISON VALVES FUEL LOSS STABILIZED. 45 MIN LEG FUEL LOST ANOTHER 8000LBS. DIVERTED, PERFORMED FUEL JETTISON SYS OPN TEST 28-31-SDR DL777091027Fuse · blownEMERGENCY LIGHTS INOP ON SEAT ROWS 30-40 BOTH AISLES. REPLACED FUSE ON M33404 POWER SUPPLY AND REPAIRED SHORTED WIRE AT ONE LOCATION.SDR DL777090633Chiller · odorCREW REPORTED SMOKY ODOR AT CTR GALLEY AREA. AFTER ISOLATING THE GALLEY THE ODOR DISSIPATED. CONTINUE ON THE ATL. FOUND M2 CHILLER FAILED. REMOVED AND REPLACED M2 CHILLER W/ MFPN267SV AND OPS CHECK PER AMM.
Back to N862DA