N862DA
Service difficulty reports · 88
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N862DA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N862DA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DL777081650Engine · fluctuatesRT ENG PARAMETERS FLUCTUATED AND ENG PWR SHORTFALL AT FL390 WITH ENG RESPONSE EICAS MSG. PERFORMED QRH 7.25 AND DESCENDED TO FL310. CORRECTED PROBLEM. FUEL TEMP WAS -22 AND OAT -56. MTC IN PROGRESS.SDR DL777081377Engine · inoperativeLEFT ENGINE START VALVE FAILED TO OPEN AFTER PUSHBACK. RTB AND APPLIED MEL AND PERFORMED A MANUAL START.SDR DL777080549Engine · malfunctionedNR 1 ENGINE REPLACED DUE TO HOC.SDR DL777080330Engine · making metalAPU AUTO SHUTDOWN REPLACED APU PER TRANSMITTAL 11T007.SDR DL777071390Controller · unknownATB DUE TO L1 WINDOW HEAT STATUS MESSAGE. REPLACED CONTROLLER.SDR DL777060883Engine · damagedNBR 1 ENGINE REPLACED DUE FAILED BORO INSPECTION DAMAGE TO THE 5 TH STAGE COMPRESSOR. ETOPS CATEGORY (F): ANY OTHER EVENT DETRIMENTAL TO ETOPS.SDR DL777060414Odor · detectedAFTER LANDING F/A SMELLED ELECTRICAL FUMES ON CAPTS SIDE OF AFT GALLEY. SMELL WAS GONE BY END OF DEPLANING INSP AFT GALLEY AREA. NO EVIDENCE OF SMOKE OR ELECT SMELL.SDR DL777060331Cooling Fan · failedWORKING MCO FOR RIGHT FAN STATUS MSG EQUIP COOLING RETURNED SYST TO NML. PERF RESET REF FIM 21-27-00. EQUIP COOLING MAT TEST FAIL. MTC MSG 21-14022. AFT FAN CONNECTED. EVIDENCE OF ELEC BURNING SMELL IN FLT DECK AND FWD CARGO AREA. DISCONNECTED FAN MCO SSDR DL777060330Motor · burned outF/O SEAT ELECTRICALLY INOPERATIVE. BURNING SMELL FROM SEAT MOTOR. FWD TO MCO AND PLACARD IAW MEL 25-11-01A. SEAT CIRCUIT BREAKER IN E/E PULLED AND COLLARED. REMOVED AND REPLACED F/O SEAT IAW MM. OPS CK GOOD. MCO/PLAC REMOVED. ETOPS CATEGORY (F): ANY OTSDR DL777060291Smoke Detector · malfunctionedON TAXI THE SMOKE DETECTOR SOUNDED IN VICINITY OF 2R. F/A REPORTED SEEING PREMIUM 3 ON PANEL. SIGNAL STOPPED SHORTLY AFTER. RAN CABIN TEST FULL TEST. NO SMOKE DETECTOR FAULT RECORDED.SDR DL777060214Blade · damagedNR 2 ENG FAILED BOROSCOPE, INTERNAL BLADE DAMAGE. REPLACED ENGINE.SDR DL777050560Fuse · blownEMERG LIGHTS IN FORWARD TOURIST CLASS SEATS INOP. REPLACED FUSE IN PWR SUPPLY, CKS GOOD.SDR DL777050460Cradle · unserviceableUPCU AT 3A SPARKED WHEN CORD PINCHED IN SEAT ASSY. FOUND CORD ON CRADLE SPARKED. REMOVED AND REPLACED CRADLE.SDR DL777050391Wire · damagedEMERGENCY LIGHTS FOR SEATS IN C ZONE INOP, REPAIRED WIRING.SDR DL777050215Power Supply · failedFLT ATTENDANT ADVISE, ON DESCENT ALL EMERGENCY LIGHTS CAME ON. AFT CABIN FLOOR PROX LIGHTS NOT ON. VERIFIED AFT CABIN ZONE SEAT PROX LIGHTS INOP. FOUND EMERGENCY LIGHTS PWR SUPPLY M33401 AT DOOR 3R BAD. REPLACED M33401 PWR SUPPLY AND BATTERY PACK. LOANED SDR DL777050208Fuse · blownEMERGENCY LIGHTS OUT ON MIDDLE ROW AT 45 THRU 56. REPLACED FUSE IN POWER SUPPLY.SDR DL777050038Fuse · blownAFT ZONE EMERGENCY PATH LIGHTS INOP. REPLACED POWER SUPPLY.SDR DL777040825Fan · smokeRECIRC FAN STATUS MSG AFT UPPER RECIRC FAN IS OFF, IT CAUSED SOME SMOKE TO ENTER THE CABIN PRIOR TO SHUTTING DOWN THEN SMOKE DISSIPATED QUICKLY. MAT MTC MSG 21-24500. FOUND UPPER AFT RECIRC FAN CB TRIPPED. REPLACED SAME.SDR DL777040771Power Supply · inoperativeSEAT MOUNTED EMERGENCY LIGHTS AT ROWS 45-56 ARE NOT TESTING. REPLACED POWER SUPPLY.SDR DL777040380Altimeter · inoperativeSTANDBY AIRSPEED INOP, STANDBY ALTIMETER INOP. MAT FAULTS MTC MSG 34-19908 AND 34-18893. REPLACED STANDBY ALTIMETER IND PER AMM. STANDBY ALT AND STANDBY A/S IND NOW CHECK OKAY.SDR DL777040370Fuse · inoperativeEMERGENCY LIGHTS AT SEATS 44 THROUGH 55 INOP. REPLACED BATTERY PACK FUSE.SDR DL777040145Fan · failedEQUIPMENT VENT FAN FAIL ELECTRICAL SMOKE ODOR IN CARGO BIN. REPLACED SAME AND TEST PER FIM, TEST OK.SDR DL777031107Slide · unsecureUPON OPENING L2 DOOR, SLIDE CAME UNLATCHED. DID NOT DEPLOY. REINSTALLED SAME.SDR DL777030863Oven · dirtyNR 2 OVEN IN FORWARD GALLEY EMITTED SMOKE AFTER HEATING UPON CLIMBOUT MUST BE CLEANED. FWD TO MCO/PLAC MEL 25-20-01H.SDR DL777030803Lens · missingSEAT MOUNTED ESCAPE PATH LIGHTING LEN(S) MISSING AT SEATS 52G & 32G RESPECTIVELY (2 WHITE). REPLACED MISSING LIGHT LENS AT SEATS 52G & 32G. LIGHTS OPS CHECK OK.SDR DL777030802Light · inoperativePASSENGER SEAT 38G SEAT MOUNTED ESCAPE PATH LIGHTING INOP. RELAMPED, DID NOT HELP. REMOVED AND REPLACED LIGHT ASSEMBLY AT SEAT 38G. OPS CHECKS OK.SDR DL777030654Odor · detectedIR-0515/16JUL/CDG/ 534841 - AT 11000 ON DESCENT FLIGHT ATTENDANTS REPORTED THE ODOR OF SMOKE /HEAT IN THE AREA OF 2 R. IT LASTED FOR APPROX 1 MINUTE. ENGINE HEAT WAS ON AT THE TIME AND WE WERE PENETRATING A RAIN SHOWER. CA-INSPECTION OF DOOR 2 R AREA PESDR DL777021477Power Supply · failedMID GALLEY EMERGENCY LIGHTS CYCLE ON/OFF WITH FLT DECK IN THE OFF POSITION FOUND POWER SUPPLY M33099 AT FAULT. REPLACED EMERGENCY LIGHT POWER SUPPLY.SDR DL777020106Coffeemaker · malfunctionedGALLEY AFT COFFEEMAKER C/B POPPED AND SPARKS OBSERVED BY F/A. REPLACED COFFEEMAKER NUMBER 4 AT MID GALLEY. CHECKS GOOD.SDR DL777011748Autothrust Sys · malfunctionedAFTER ENG START WITH BRAKES SET THE AUTOTHROTTLES ENGAGED BY THEMSELVES AND ADVANCED TO THE TAKEOFF POWER. NO PRESENT LEG FAULTS NO EXISTING FDES. PERFORMED SYS TEST, RESET OF LT AND RT AIMS CABINETS, PERFORMED LT AND RT TMC. CABINET SERVO LOOP TESTS ALL CKSDR DL777011374Oven · overheatedFRC-253-13809 LOCATION CABIN 2R OVEN OVERHEATS. FWD TO MCO AND PLACARD PER MEL 25-20-01. PULLED AND COLLARED CBS. OVEN OVERHEATS. THE F/A HAD TO PULL BREAKERS TO SHUTOFF. OVEN LOC 809 NR 2 OVEN.SDR DL777010806Coffeemaker · malfunctionedAFT COFFEEMAKER SPARKING. REPLACED COFFEEMAKER, CHECKS OK.SDR DL777010697Oven · overheatedOVEN OVERHEATED. REPLACED OVEN, SYSTEM CHECKS NORMAL.SDR DL777010520Connector · arcedFOUND PLUG J1 CONNECTOR P1 AT SEAT 52AB ARCED. ACTIVATED IFE SYSTEM CLEARED MCO 445269003 REMOVED AND REPLACED AVU AT SEAT 52 A/B-P/N 1301273-11 AND SEAT TO SEAT CABLE P/N 130902-016.SDR DL777010316Audio Video Unit · odorIN FLIGHT AN ELECTRICAL ODOR WAS EVIDENT AROUND SEAT 37 A/B AND SEAT 38 A/B. NO SMOKE WAS VISIBLE NO CAUSTIC BURNING EYES OR NOSE. ENTERTAINMENT SYS/CABIN LIGHTS/GALLEYS WERE DEPOWERED. ODOR WAS NO LONGER EVIDENT. VISUAL INSP OF ALL AUDIO/VIDEO POWER BOXESSDR DL777001717O-Ring · damagedLT ENGINE OIL QUANTITY LOW, READS 4 QTS 6 HRS INTO FLIGHT, 1 QT AT 8 HRS. FOUND LEFT ENGINE PRESSURE OIL FILTER BOWL O-RING DAMAGED. REPLACED O-RINGS AND FILTER. LEAK CKS OK. ENGINE SERVICED WITH 16 QTS EXXON 2197.SDR DL777000636Connector · overheatedDURING CONFIDENCE CHECK, FOUND NO MONITORS OPERATING AT VDU 8 AND 9, VDU 8 J2 CONNECTOR FOUND OVERHEATED. NEED NEW J2 CONNECTOR. C/B P210 C1 VIDEO DIST 4 PULLED AND COLLARED. ALL CONNECTORS AT VDU 8 BAGGED AND TIED BACK. NEED NEW J2 CONNECTOR (P/N W6961).SDR DL777000247B Nut · looseRIGHT ENGINE ANTI-ICE VALVE CLOSED IN FLIGHT INTERMITTENTLY. SHOULD HAVE REMAINED OPEN. SEVERAL B-NUTS LOOSE ON EAI CONTROLLER. TIGHTENED B-NUTS AND ALL SYSTEMS CHECK GOOD. NOT ABLE TO REC NO ICE CLEARANCE.
Back to N862DA