N8646B
Service difficulty reports · 132
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N8646B' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N8646B' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2026100509772Lamp · inoperativeR2 DOOR EXTERIOR EMERGENCY LIGHT INOPERATIVE. REPLACED THE LAMPS IN THE EXTERIOR EMERGENCY LIGHT IAW AMM 33-51-04. OPS CHKD GOOD.SDR SWAA2026062204623Intercostal · crackedCRACKED INTERCOSTAL BS 344 - 360, RBL 12, WL 200. REMOVED AND REPLACED INTERCOSTAL IAW SRM 51-40-02 AND DWG 141A5400, REV -.SDR SWAA2026062204622Intercostal · crackedCRACKED INTERCOSTAL BS 344 TO 360, BL 0, WL 200. REMOVED AND REPLACED THE INTERCOSTAL BS 344 - 360, BL 0 IAW SRM 51-40-02 AND DWG 141A5400, REV -.SDR SWAA2026062204302Floor Panel · pulledFLOOR PANEL 231HF LOWER SKIN HAS AREAS OF PULLED STRANDS. FABRICATE REPLACEMENT FLOOR PANEL IAW SRM 53-00-50-2R-0.SDR SWAA2026062204303Floor Panel · pulledFLOOR PANEL 231MF UPPER SKIN HAS AREAS OF PULLED STRANDS. FABRICATED A REPLACEMENT FLOOR PANEL IAW SRM 53-00-50-2R-0.SDR SWAA2026062204318Floor Panel · pulledFLOOR PANEL 241RF UPPER SKIN HAS AREAS OF PULLED STRANDS. DUE TO EXTENT OF THE DAMAGE FABRICATED NEW 241RF FLOOR PANEL IAW SRM 53-00-50-2R-0.SDR SWAA2026062204311Floor Panel · pulledFLOOR PANEL 241UF UPPER SKIN HAS AREAS OF PULLED STRANDS. THE FLOOR PANEL WAS REPLACED WITH A NEWLY FABRICATED FLOOR PANEL IAW SRM 53-00-50-2R-0, DWG 146A5810.SDR SWAA2026062204315Floor Panel · pulledFLOOR PANEL 242EF UPPER SKIN HAS AREAS OF PULLED STRANDS. REPAIRED IAW SRM 53-00-50-2R-0-B00275, REPAIR GENERAL.SDR SWAA2026062204316Floor Panel · pulledFLOOR PANEL 242FF UPPER SKIN HAS AREAS OF PULLED STRANDS. THE FLOOR PANEL WAS REPLACED WITH A NEWLY FABRICATED FLOOR PANEL IAW SRM 53-00-50-2R-0, DWG 146A5810.SDR SWAA2026062204317Floor Panel · pulledAFT FLOOR PANEL 242D UPPER SKIN HAS AN AREA OF PULLED STRANDS. REPAIRED IAW SRM 53-00-50-2R-1-B00276, REPAIR 1.SDR SWAA2026062204308Floor Panel · pulledFWD FLOOR PANEL 222CF UPPER SKIN HAS PULLED STRANDS ALONG THE AFT EDGE. FWD FLOOR PANEL 222CF WITH UPPER SKIN WAS REPAIRED IAW SRM 53-00-50-2R-1.SDR SWAA2026062204309Floor Panel · pulledFWD FLOOR PANEL 222DF UPPER SKIN HAS PULLED STRANDS ALONG THE FWD EDGE. FWD FLOOR PANEL 222DF DAMAGE WAS REPAIRED IAW SRM 53-00-50-2R-1.SDR SWAA2026062204620Shield · corrodedCORROSION ON ACB FWD SHIELD WEB BETWEEN BS 767 - 792, RBL 25, WL 156. REMOVED AND REPLACED THE SHIELD IAW SRM 51-40-02-0G-0, AND DWG 146A0081, REV A.SDR SWAA2026062204523Threshold Web · corrodedCORROSION ON FCB SUB THRESHOLD WEB BETWEEN BS 440 - 492, RBL 25, WL 156. P 5 REJECT DUE TO COMMON STRUCTURE TO SUB-THRESHOLD HAS BEEN COUNTERSINK. REMOVED AND REPLACED FCB THRESHOLD WEB IAW SRM 51-40-02-0G-0, DWG 143A8330, REV B.SDR SWAA2026062204121Floorbeam · corrodedCORROSION ON BS 947 FLOORBEAM UPPER FLANGE, LBL 49 AND LBL 53, WL 208. PERFORMED REPAIR ON THE FLOORBEAM IAW SRM 53-70-51-2R-5, REPAIR 5.SDR SWAA2026062204124Floorbeam · corrodedCORROSION ON BS 986.5 FLOORBEAM UPPER FLANGE AT NUTPLATE HOLE LBL 43, WL 208. REPAIRED THE FLOORBEAM IAW SRM 53-70-51-2R-6, FIG 205.SDR SWAA2026062204122Support Angle · corrodedCORROSION ON RT ZEE SUPPORT ANGLE AT BS 986.5+6, RBL 37, WL 208. REMOVED AND REPLACED RT ZEE SUPPORT ANGLE AT BS 986.5, RBL 37, WL 208 IAW SRM 51-40-02-0G-0, AND DWG 147A5700, REV A.SDR SWAA2026062204270Support Angle · corrodedCORROSION ON RT ZEE SUPPORT ANGLE AT BS 986.5+6, RBL 32, WL 208. REMOVED AND REPLACED RT ZEE SUPPORT ANGLE IAW SRM 51-40-02-0G-0, AND DWG 147A5700, REV A.SDR SWAA2026062204271Sill Drain · corrodedCORROSION ON ASD MOP SILL AT BS 947+8, RBL 56, WL 208. REMOVED & INSTALLED NEW AFT SERVICE DOOR MOP SILL FROM 887+10 -1006 IAW SRM 51-40-02; DWG 147A8501 REV:A,; & DWG 147A0000 REV A.SDR SWAA2026062204268Support Strap · corrodedCORROSION ON SHEAR WEB SUPPORT STRAP AT BS 1016+3, RBL 3, WL 208. REMOVED AND REPLACED SHEAR WEB SUPPORT STRAP IAW SRM 51-40-02-0G-0 AND DWG 147A5700, REV A.SDR SWAA2026062204272Support Strap · corrodedCORROSION ON SHEAR WEB SUPPORT STRAP AT BS 1016+3 AND 1016+12, LBL 3, WL 208. REMOVED AND REPLACED THE SHEAR WEB STRAP IAW SRM 51-40-02-0G-0, AND DWG 147A5700, REV A.SDR SWAA2026062204281Support Bracket · crackedLOWER BULKHEAD SUPPORT BRACKET AT BS 867, LBL 3, WL 156 CRACKED. REMOVED AND REPLACED THE SUPPORT BRACKET IAW SRM 51-40-02-0G-0.SDR SWAA2026062204273Support Bracket · crackedACB FWD BULKHEAD SUPPORT BRACKET AT BS 731, BL 0, WL 160 IS CRACKED. REMOVED AND REPLACED ACB FWD BULKHEAD BRACKET ASSY IAW SRM 51-40-02 AND DWG 144A2600, REV -.SDR SWAA2026062204297Access Panel · debondedACCESS PANEL 191FL L/E IS DISBONDED. REPAIRED DISBONDED L/E ON ACCESS PANEL 191FL IAW SRM 53-30-70-2R-1 AND SRM 51-70-05-2R-6.SDR SWAA2026062204269Support Angle · corrodedCORROSION ON LT ZEE SUPPORT ANGLE AT BS 986.5+6, LBL 37, WL 208. REMOVED AND REPLACED RT ZEE SUPPORT ANGLE BS 986.5+6, LBL 37, WL 208 IAW SRM 51-40-02, SRM 51-40-02-0G-0, AND DWG 147A5700, REV A;SDR SWAA2026062203781Sidewall Support · corrodedCORROSION FOUND ON RT AFT CARGO FLOOR TO SIDEWALL SUPPORT, BS 727 - 747, RBL 21, WL 156. REMOVED AND REPLACED SIDEWALL SUPPORT IAW SRM 51-40-02, AND DWG 146A7500, REV-.SDR SWAA2026062203782Sidewall Support · corrodedCORROSION FOUND ON AFT CARGO BAY RT FLOOR TO SIDEWALL SUPPORT BS 867 - 927, RBL 21, WL 157. REMOVED AND REPLACED SIDEWALL SUPPORT IAW SRM 51-40-02-0G-0 AND DWG 146A7500 REV-.SDR SWAA2026062203788Floor Support · corrodedCORROSION ON ACB FLOOR PANEL TO FLOOR PANEL SUPPORT BS 887, RBL 3 - 12, WL 168. REMOVED AND REPLACED FLOOR PANEL SUPPORT IAW SRM 51-40-02 AND DWG 146A7500 REV-.SDR SWAA2026062203783Threshold Web · corrodedCORROSION ON ACB SUB THRESHOLD WEB AT BS 797 - 824, RBL 26, WL 157. REMOVED A REPLACED ACB SUB THRESHOLD WEB IAW SRM 51-40-02-0G-0, AND DWG:146A8340 REV-.SDR SWAA2026062203786Strap · corrodedCORROSION ON ACB THRESHOLD TRACK FASTENER HOLES AT BS 797 - 824, RBL 19, WL 158. REPLACED THE STRAP IAW SRM 51-40-02-0G-0.SDR SWAA2026062203784Support · corrodedCORROSION ON LH AFT BODY TO SIDE WALL SUPPORT BS 736 - 799, LBL 21, WL 156. REMOVED AND REPLACED SIDEWALL SUPPORT IAW SRM 51-40-02 AND DWG 146A7500, REV-;SDR SWAA2026062203785Support · corrodedCORROSION ON ACB BODY TO AFT BULKHEAD SUPPORT BS 947, LBL 10, RBL 15, WL 179. REMOVED AND REPLACED BULKHEAD SUPPORT IAW SRM 51-40-02, AND DWG 149A8117, REV-.SDR SWAA2026062204619Sidewall Panel · corrodedCORROSION ON SIDEWALL FCB BS 500C+16.5; BS 500C+19; BS 500D+2.5; BS 500D+7; BS 500D+11 RBL 24.5. THE DAMAGE WAS REPAIRED PER SRM 53-00-53-2R-5 (REPAIR 5) AND EA M-22-153-01550'.;SDR SWAA2026062203985Shield · corrodedCORROSION ON AFT SHIELD FCB BS 480+16, BS 500+14, RBL 24.5. REMOVED AND REPLACED FCB AFT SHIELD IAW SRM 51-40-02-0G-0, AND DWG 143A0080, REV -.SDR SWAA2026062203777Doubler · corrodedBS 727, BL 0, EXTERNAL SKIN AT PRESSURE DRAIN VALVE WAS CORRODED AT RIVETS. REMOVED AND REPLACED PRESSURE DRAIN VALVE DOUBLER BS 727, BL 0, WL 148 IAW SRM 51-40-02, AND DWG 146A3230 REV -.SDR SWAA2026062203199Floor Panel · pulledFLOOR PANEL 231XF UPPER SKIN HAS AREAS OF PULLED STRANDS. THE FLOOR PANEL WAS REPLACED WITH A NEWLY FABRICATED FLOOR PANEL IAW SRM 53-00-50-2R-0 & DWG 144A5810.SDR SWAA2026062203201Floor Panel · pulledFLOOR PANEL 231ZF UPPER SKIN HAS AREAS OF PULLED STRANDS. THE FLOOR PANEL WAS REPLACED WITH A SERVICEABLE FLOOR PANEL IAW SRM 51-10-02-0G-0, PARA 9.A.1.SDR SWAA2026062203200Floor Panel · pulledFLOOR PANEL 241BF UPPER SKIN HAS AREAS OF PULLED STRANDS. THE FLOOR PANEL WAS REPLACED WITH A NEWLY FABRICATED FLOOR PANEL DUE TO AMOUNT OF ALL DAMAGE IAW SRM 53-00-50-2R-0, AND DWG 144A5810.SDR SWAA2026062203204Floor Panel · pulledFLOOR PANEL 242AF UPPER SKIN HAS AREAS OF PULLED STRANDS. THE FLOOR PANEL WAS REPLACED WITH A NEWLY FABRICATED FLOOR PANEL IAW SRM 53-00-50-2R-0, DWG 144A5810.SDR SWAA2026062203202Floor Panel · pulledFLOOR PANEL 232SF UPPER SKIN HAS MULTIPLE AREAS OF PULLED STRANDS. THE FLOOR PANEL 232SF WAS REPLACED WITH A SERVICEABLE FLOOR PANEL IAW SRM 51-10-02-0G-0, PARA 9.A.1.SDR SWAA2026062203203Floor Panel · pulledFLOOR PANEL 241AF UPPER SKIN HAS AREAS OF PULLED STRANDS. REPAIRED IAW SRM 53-00-50-2R-0-B00275,SDR SWAA2026062203776Scuff Plate · crackedACD FWD CORNER SCUFF PLATE IS CRACKED. REMOVED AND REPLACED ACD FWD CORNER SCUFF PLATE IAW SRM 51-40-02, AND DWG 146A8341, REV A.SDR SWAA2025110731301Fuse · failedEMERGENCY EXIT LIGHTS L01207 AND L01208 DO NOT ILLUMINATE. REMOVED AND REPLACED FUSE IN M1694 AND PERFORMED A GOOD TEST IAW AMM 33-51-06-960-804.SDR SWAA2025081303565Circuit Breaker · brokenCABIN EMER LIGHTS C/B BROKEN OFF. R & R CABIN EMERGENCY LIGHT BREAKER IAW WDM #33-51-11. OPS CK GOOD. ALSO SWPM 20-30-00.SDR SWAA2024082829711Light · dimIN THE PASSENGER CABIN; THE PHOTO LUMINESCENT LIGHT STRIP UPPER SURFACES HAVE PART NUMBER STICKERS IN NUMEROUS AREAS.<[01] CLEANED PHOTO LUMINESCENT LIGHT STRIP UPPER SURFACES IAW AMM 25-00-00.;[02] REJECT: CORRECTIVE ACTION #1 IS SIGNED OFF BUT TASK IS NOT COSDR SWAA2024082829180Battery Pack · inoperativeR2 DOOR OVER-DOOR EMERGENCY EXIT SIGN LIGHT INOP.<[01] R/R BATTERY PACK(AFT R/H GALLEY) PER AMM 33-51-06. OPS CHECK GOOD.;[02] VERIFIEDSDR SWAA2024082826415Intercostal · crackedREMOVED FLOOR PANEL 231UF FOR 540 INTERCOSTAL CRACKED<[01] OK TO CLOSE PANEL.;[02] REMOVED AND REPLACED FLOOR PANEL PER AMM 53-21-00.;[03] INSPECTED WORK PERFORMEDSDR SWAA2024082826413Vapor Barrier · elongatedVAPOR BARRIER WEB UNDER VERTICAL LEG OF UPPER CHORD AT LBL 20 HAS TWO ELONGATED FASTENER HOLES<[01] REPAIRED PER EA 24-157-02249;[02] 1. DAVID BASTIAN (TECHNICIAN); 21-AUG-2024 15:59 UTC<BR>REPAIRED PER EA 24-157-02249 RIISDR SWAA2024082823152Beam · crackedR/H AC BAY LWR T CHORD CRACKED AT STA 663 RBL 42.<[01] DUPLICATE DISCREPANCY. SEE FAULT TTG8Q00V12TU FOR CHORD REPLACEMENT. MPM 52.02.05SDR SWAA2024082823151Vapor Barrier · crackedR/H AC BAY STA 663 VAPOR BARRIER UPPER CHORD CRACKED AT RBL 37<[01] PARTS DATA UPDATE ONLY;[02] MATCH DRILLED AND DEBURRED NEW CHORD PER SRM 51-40-02/SRM51-10-02.;[03] OK TO INSTALL NEW CHORD (RII);[04] INSTALLED AND DOMED SEALED FASTENERS COMMON TO FUEL TANK
Back to N8646B