N883GA
Service difficulty reports · 69
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N883GA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N883GA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR WX0A071391Skin · corrodedFOUND CORROSION ON INNER SKIN UNDER BELLY DRAIN RIGHT SIDE OF LONG 30 APPROX STA 731. REMOVED AND REPAIRED FUSELAGE SKIN.SDR WX0A071090Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ASDR WX0A071074Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A070925Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A070907Unknown · sparksWHILE TAXIING OUT A LARGE SPARK APPEARED OUT OF THE GLARE SHIELD PANEL, REPOSITIONED WIRES IAW 56-10-01. OPS CHECK OF WINDSHIELD TEMP CONTROLLER IAW 30-41-00, OPS CHECK NORMAL AT THIS TIME. AIRCRAFT RETURNED TO SERVICE.SDR WX0A070896Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A070725Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A070724Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A070536Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A070451Beam · corrodedDURING BOW 1C/2C/S1/S2/S4, WO 94586 CORROSION WAS FOUND ON THE AFT CARGO DOOR BEAM THAT WAS OUT OF LIMITS STA 1155 TO 1211. ADDRESSED AS REQUIRED.SDR WX0A070448Cusp Web · crackedDURING BOW 1C/2C/S1/S2/S4, IN THE CABIN FOUND CRACK IN LEFT CUSP AT STA 228. ADDRESSED AS REQUIRED.SDR WX0A070447Cusp Web · damagedDURING BOW 1C/2C/S1/S2/S4, CUSP MEMBRANE COLLAR FOUND DAMAGED AT STA 905 RIGHT. ADDRESSED AS REQUIRED.SDR WX0A070446Cusp Web · crackedDURING BOW 1C/2C/S1/S2/S4, RIGHT CUSP AT STA 225 FOUND CRACKED, OUTBOARD OF SEAT TRACK 6. ADDRESSED AS REQUIRED.SDR WX0A070445ACusp Web · crackedDURING BOW 1C/2C/S1/S2/S4, LEFT CUSP WAS FOUND CRACKED BETWEEN STA 218 - 237. ADDRESSED AS REQUIRED.SDR WX0A070443Seat Track · crackedDURING BOW 1C/2C/S1/S2/S4 FOUND NR 5 SEAT TRACK SUPPORT CASTING CRACKED AT STA 927, JUST ABOVE FUEL TANK. REPLACED SUPPORT CASTING MPN 3925812.2 PER SRM 51-01, REF E58 6446902 ADDRESSED AS REQUIRED.SDR 070183Battery Pack · no testDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK. A SATISFSDR 070130Unknown · unknownAIRCRAFT 883GA, FLIGHT 762 DURING CRUISE FLIGHT THE CARGO SMOKE DETECTOR LOOP LIGHT ILLUMINATED. FLIGHT CREW FOLLOWING QRH PROCEDURES TESTED THE SYSTEM BY PRESSING AND HOLDING THE WARN/CAUTION LTS TEST SWITCH AND ALL CDSCP LIGHTS ILLUMINATED. RETESTING THE SSDR 070077Light · no testDURING A ROUTINE OVERNIGHT RON CHECK MAINTENANCE INSPECTION, LAS VEGAS MAINTENANCE REPORTED A FORWARD EMERGENCY EXIT PORTABLE LIGHT WOULD NOT TEST. LAS VEGAS MAINTENANCE FURTHER REPORT THE REMOVAL AND INSTALLATION OF AN EMERGENCY EXIT PORTABLE LIGHT. A SATISSDR 070059Skin · crackedDURING A ROUTINE MAINTENANCE INSPECTION MAINTENANCE REPORTED AN APPARENT CRACK IN AN UPPER WING SURFACE PANEL AT APPROXIMATELY WING STATION 48.00. FURTHER INSPECTION REVEALED A CRACK OF APPROXIMATELY 13-INCHES LENGTH IN THE COMPOSITE PANEL AT WING STATION 47.