N9004F

Service difficulty reports · 123

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N9004F' AND registry_match = 'registration'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR AALA20190529010Damper · low pressureAIRCRAFT WAS GROUNDED: R2 DOOR DAMPER LOW. MAINTENANCE SERVICED DAMPER TO PROPER PRESSURE PER STANDARD PRACTICES.May 29, 2019 · N9004F · Airbus A319115 · Passenger/Crew DoorsSDR AALA201905319007Proximity Sensor · out of adjustAIRCRAFT WAS GROUNDED: PILOT REPROTS 2R DOOR IN FLIGHT ARM LEVER MOVES UP SLIGHTLY TRIGGERING DISARM INDICATION ON DOORS. MAINTENANCE ADJUSTED R2 DOOR PROXIMITY SENSOR IAW AMM 52-72-00. OPS CHECK GOOD.May 26, 2019 · N9004F · Airbus A319115 · Door Warning SystemSDR AALA201905249002Battery · dischargedAIRCRAFT IN BASE VISIT: MAINTENANCE REPORTS OPS CHECK OF THE EMERGENCY LIGHTING SYSTEM FAILED WHILE ACCOMPLISHING CARD 25-94-03. FAULTS BAT/EPSU 10WL FWD 3 BAT/ESPU 11WL EMER L REQS TROUBLESHOOTING. ACCOMPLISHED TSM 35-51-00-810-829-A AND TSM 35-51-00-810-855May 23, 2019 · N9004F · Airbus A319115 · Emergency LightingSDR AALA201905209002Spacer · bentAIRCRAFT WAS GROUNDED: PILOT REPORTS DURING FLIGHT, 4R DOOR SLIDE HANDLE PHYSICALLY MOVES BY ITSELF OUT OF DETENTION WHILE AIRCRAFT IS IN PRESSURIZED FLIGHT, CAUSING THE DOOR TO DISARM IN FLIGHT. DISARM INDICATION CAN BE SEEN ON ECAM AND FLIGHT ATTENDANT CONTRMay 19, 2019 · N9004F · Airbus A319115 · Escape SlideSDR AALA201904187011Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON CENTER SILL SHAPE FITTING BETWEEN FR 66 AND FR 68 AT S23R. REPLACED CENTER SILL SHAPE FITTING PER SRM 51-72-11.Apr 17, 2019 · N9004F · Airbus A319115 · Fuselage Miscellaneous StructureSDR AALA201904187010Fitting · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON CORNER FITTING AT FR 66 AND S23R. REPLACED CORNER FITTING PER SRM 51-72-11.Apr 17, 2019 · N9004F · Airbus A319115 · Fuselage Main, Attach FittingsSDR AALA201904187009Fitting · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON CORNER FITTING AT FR 68 AND S23R. REPLACED CORNER FITTING PER SRM 51-72-11.Apr 17, 2019 · N9004F · Airbus A319115 · Fuselage Main, Attach FittingsSDR AALA201904187007Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON LOWER SILL BETWEEN FR 66 AND FR 68 AT S23R. REPLACED LOWER SILL PER SRM 51-72-11.Apr 17, 2019 · N9004F · Airbus A319115 · Fuselage Miscellaneous StructureSDR AALA201904254011Hinge Fitting · damagedAIRCRAFT IN BASE MAINTENANCE: LEFT HAND ELEVATOR #4 HINGE FITTING HAS DAMAGE / WEAR. REPLACED HINGE FITTING PER AMM 55-16-42.Apr 16, 2019 · N9004F · Airbus A319115 · Elevator StructureSDR AALA20190424010Hinge Fitting · damagedAIRCRAFT IN BASE MAINTENANCE: LEFT HAND ELEVATOR #5 HINGE FITTING HAS DAMAGE / WEAR. REPLACED HINGE FITTING PER AMM 55-16-42.Apr 16, 2019 · N9004F · Airbus A319115 · Elevator StructureSDR AALA201904254009Hinge Fitting · damagedAIRCRAFT IN BASE MAINTENANCE: RIGHT HAND ELEVATOR #5 HINGE FITTING HAS DAMAGE / WEAR. REPLACED HINGE FITTING PER AMM 55-16-42.Apr 16, 2019 · N9004F · Airbus A319115 · Elevator StructureSDR AALA201809279011Trim Panel · detachedL1 DOOR ASSIST HANDLE TRIM CAME OFF. MAINTENANCE INSTALLED THE TRIM ON THE L1 DOOR AND PERFORMED SATISFACTORY OPERATIONAL CHECK.Sep 26, 2018 · N9004F · Airbus A319115 · Passenger/Crew DoorsSDR AALA201807109037Actuator · leakingTHE AIRCRAFT WAS GROUNDED. CREW COMPLAINED OF SMELL IN CABIN POSSIBLE HYDRAULIC INGESTION IN PACKS. NOTICED STRONG SMELL IN CABIN ADVISED IMMEDIATE DEBOARDING OF AIRCRAFT. FOUND RIGHT HAND MAIN LANDING GEAR LOCK STAY ACTUATING CYLINDER LEAKING. REPLACED MLG LOJul 7, 2018 · N9004F · Airbus A319115 · Landing Gear ActuatorSDR AALA201806159008Power Supply · no testEMERGENCY POWER SUPPLY 13WL FAILED A CIDS TEST. REPLACED THE POWER SUPPLY IAW 33-51-38.Jun 13, 2018 · N9004F · Airbus A319115 · Emergency LightingSDR AALA201709059003Computer · faultedCENTER TANK NR 1 FUEL PUMP FAULT AFTER TAKE OFF. MAINTENANCE TROUBLESHOT IAW TSM 28-21-00. MAINTENANCE REPLACED FQIC IAW AMM 28-42-34. ACCOMPLISHED AN OPERATIONAL CHECK IAW AMM 28-21-00.Sep 4, 2017 · N9004F · Airbus A319115 · Fuel Boost PumpSDR AALA201709059002Relay · faultedJUST AFTER CENTER FUEL TANK EMPTIED, NUMBER 1 PUMP IN CENTER TANK FAULTED. TURNED PUMP OFF IAW ECAM. MAINTENANCE PERFORMED TROUBLESHOOTING IAW TSM 28-21-00. REPLACED THE PUMP AUTO CONTROL RELAY 41QA IAW AMM 28-21-00. ACCOMPLISHED SATISFACTORY OPERATIONAL CHSep 1, 2017 · N9004F · Airbus A319115 · Fuel Boost PumpSDR AALA201708089001Sign · brokenAIRCRAFT WAS NOT GROUNDED. L2 DOOR LOWER EMERGENCY EXIT SIGN IS BROKEN OFF LOWER FASTENER. REPLACED L4 DOOR EMERGENCY EXIT LIGHT PER MM 33-51-13-000-001.Aug 3, 2017 · N9004F · Airbus A319115 · Emergency LightingSDR AALA201707119003Engine · malfunctionedABRUPT YAW ON TAKEOFF PRIOR TO 80 KNOTS. SYMMETRIC ENGINE INDICATIONS. REJECTED TAKEOFF AND RETURNED TO GATE. ACCOMPLISHED FURTHER RESEARCH AND FOUND NO ADDITIONAL INFORMATION.Jul 6, 2017 · N9004F · Airbus A319115 · Engine (Turbine/Turboprop)SDR AALA201707069007Flashlight · not seatedFLASHLIGHT AT FLIGHT ATTENDANT NR 1 JUMPSEAT DOES NOT TEST. MAINTENANCE RESEATED FLASHLIGHT AND REPLACED TAMPER TAB. ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK.Jul 5, 2017 · N9004F · Airbus A319115 · Emergency EquipmentSDR AALA20170228024Smoke Detector · false activationAIRCRAFT WAS NOT GROUNDED. SMOKE DETECTOR IN THE FORWARD LAVATORY WARNING INDICATION WENT ON AND OFF 3 OR 4 TIMES IN ABOUT A MINUTE. NO EVIDENCE OF SMOKE. PERFORMED TEST OF THE SMOKE DETECTOR IAW AMM 26-17-00. NO FAULTS FOUND. OPERATIONAL CHECK GOOD.Feb 26, 2017 · N9004F · Airbus A319115 · Smoke DetectionSDR AALA20170127001Battery · dischargedAIRCRAFT WAS NOT GROUNDED. EMERGENCY POWER SUPPLY UNIT AT 10WL FAILED TEST. REMOVED AND REPLACED EPSU BATTERY IAW AMM 33-51-38. OPERATIONAL CHECK GOOD.Jan 26, 2017 · N9004F · Airbus A319115 · Emergency LightingSDR AALA20150519005Floor Panel · delaminatedAFT CARGO COMPARTMENT FLOOR PANEL 151ZG HAS DELAMINATED TO PREVIOUS REPAIR. R & R WITH FABRICATED FLOOR PANEL IAW SRM 53-02-00 PARA 8H FIG 209.May 19, 2015 · N9004F · Airbus A319115 · Fuselage Floor PanelSDR AALA20150325008Skin · damagedDEEP DENT WITH GOUGE BETWEEN FRAME 55 & 57, BETWEEN STRINGERS 39 LT & 40 LT. ACCOMPLISHED EXTERNAL DOUBLER REPAIR IAW SRM 53-00-11-201 FIGURE 230.Mar 25, 2015 · N9004F · Airbus A319115 · Fuselage Main, Plate/Skin
Back to N9004F