N912SW
Service difficulty reports · 232
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N912SW' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N912SW' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWIA201126727Light · inoperativeNR 3 OVERHEAD EMERGENCY LIGHT NOT WORKING. (FLT 5545) RELAMPED EMERGENCY LIGHT.SDR SWIA201126382Bearing · wornAIRCRAFT BUFFETING FROM FL 350 TO DESCENT ABOVE 270K. (FLT 6588) REPLACED RIGHT ELEVATOR PCU ROD-END SPHERICAL BEARINGS AND ATTACHING HARDWARE. REPLACED WORN HYDRAULIC HEAT EXCHANGER ASSEMBLY, REPLACED LEFT STAB UPPER VISOR PANEL.SDR SWIA201125644Light · inoperativeNR 3 OVERHEAD EMERGENCY LIGHT INOP. (FLT 6522) RELAMPED EMERGENCY LIGHT.SDR SWIA201125543Light · inoperativeOVERHEAD EMERGENCY LIGHT ROW 10 IS OUT. (FLT 6705) RELAMPED EMERGENCY LIGHT.SDR SWIA201025362Light · inoperativeOVERHEAD EMERGENCY LIGHT AT ROW 10 OUT. (FLT 6520) RELAMPED EMERGENCY LIGHT.SDR SWIA201025013Light · inoperativeAFT CABIN CEILING LEVEL EMERGENCY FLOOD LIGHT INOPERATIVE. (FLT 6393) RELAMPED EMERGENCY LIGHT.SDR SWIA201024719Light · inoperativeEMERGENCY LIGHT AT ROW 10 IS INOP. (FLT 6657) RELAMPED EMERGENCY LIGHT.SDR SWIA201024567Light · inoperativeNR 4 AFT EMERGENCY DOME LIGHT INOP. (FLT 6180) RELAMPED EMERGECNY LIGHT.SDR SWIA201024522Light · inoperativeCEILING EMERGENCY LIGHT NR 2 INOP. (FLT 6564) RELAMPED EMERGENCY LIGHT.SDR SWIA201024353Light · inoperativeLAST EMERGENCY CEILING LIGHT INOP. (FLT 6248) RELAMPED EMERGENCY LIGHT.SDR SWIA201024352Bolt · wornAIRCRAFT EXPERIENCES BUFFETING IN CRUISE AND DESCENT. (FLT 1001) REPLACED RIGHT ELEVATOR PCU TO ELEVATOR, BOLTS AND BUSHINGS FOR ALL THREE PCU'S, AND REPLACED SHEAR PIN FOR SYS NR 2 PCU PER AMM.SDR SWIA201024063Light · inoperativeEXTERIOR EMERGENCY EXIT LIGHT NEXT TO MAIN CABIN DOOR INOP. (FLT 6543) RELAMPED EMERGENCY LIGHT.SDR SWIA201023635Contact · dirtyEMERGENCY FLOOR LIGHTING AT ROW 8 INTERMITTENT. (FLT 6458) CLEANED CONTACTS.SDR SWIA201023478Lamp · burned outFLT 6103 - NR 3 OVERHEAD EMERGENCY LIGHT INOP. RELAMPED.SDR SWIA200923732Fitting · crackedFS 621 LEFT LINTEL FITTING CRACKED. (C CHECK) REPAIRED PER REO.SDR SWIA200923731Frame · crackedFS 559 FRAME CAP ANGLE CRACKED. (C CHECK) REPAIRED PER REO.SDR SWIA200922712Connector · brokenFOUND BROKEN EMERGENCY TRACK LIGHTING PLUG CONNECTOR BROKEN AT ROW 9. (FLT 6132) REPLACED CONNECTOR ASSY AT ROW 9 TRACK LIGHTING ASSY.SDR SWIA200922711Inverter · faultyRT OVERWING EXIT FLOOR LEVEL EMERGENCY LIGHT DIM. (FLT 6132) REPLACED NR 3 INVERTER ASSY AT 3RD EMERGENCY LIGHT BATTERY PACK.SDR SWIA200922713Cover · brokenCOVER OVER AFT PORTION OF EMERGENCY LIGHTS ON FLOOR NEAR LAV IS BROKEN. (FLT 6468) REMOVED AND REPLACED EMERGENCY LIGHTS COVER STRIP COVERING FLOOR LEVEL EMERGENCY LIGHTING REFERENCE CRJ200 AMM 33-00-00.SDR SWIA200922678Connector · looseEMERGENCY FLOOR STRIP AFT OF ROW 9 IS DIM. (FLT 5999) FOUND LOOSE CONNECTOR ON POWER STRIP, SECURED CONNECTION.SDR SWIA200922677Light · inoperativeLEFT & RIGHT OVERWING CENTER EMERGENCY EXIT LIGHTS INOP. (FLT 6741) REPLACED LEFT & RIGHT OVERWING CENTER EMERGENCY EXIT LIGHTS LAMPS WITH SERVICEABLE UNITS.SDR SWIA200921728Light · inoperativeEMERGENCY FLOODLIGHT ABOVE THE LAVATORY INOP. (FLT 6083) RELAMPED EMERGENCY FLOODLIGHT.SDR SWIA200921631Window · crackedFLT 1002 - CAPTAINS SIDE WINDOW CRACKED. REPLACED WINDOW.SDR SWIA200921630Engine · overtempFLT 6605 - NR 2 ENGINE OVERTEMP. REPLACED ENGINE.SDR SWIA200921649Engine · overtempFLT 6101 - NR 1 ENGINE OVERTEMP. ACCOMPLISHED COMPRESSOR WASH.SDR SWIA200921517Connector · looseFLT 6250 - EMERGENCY FLOOR LIGHTS INOP. RESECURED CONNECTOR.SDR SWIA200921516Light · inoperativeFLT 6150 - OVERWING EMERGENCY LIGHT ON LEFT WING INOP. RELAMPED.SDR SWIA200921123Lamp · burned outFLT 6545 - EMERGENCY EXIT LIGHT INOP ABOVE ROW 10. RELAMPED.SDR SWIA200920848Module · malfunctionedFLT 5087 - ON DESCENT ALL PASSENGER O2 MASKS DEPLOYED. REPLACED CABIN PRESSURE MODULE.SDR SWIA200820668Unknown · smokeFLT 5857 - 'SMOKE TOILET' WARNING ON TAKEOFF. ACCOMPLISHED COMPRESSOR WASH ON LEFT ENGINE, REPLACED BOTH ACM'S AND COALESCER SOCKS, AND HIGH POWER ENGINE RUNS.SDR SWIA200820044Light · inoperativeFLT 6553-12, AFT EMERGENCY FLOOD LIGHT INOP. REPLACED AFT OVERHEAD EMERGENCY LIGHT.
SDR SWIA200820184Attach Fitting · crackedINTERCOSTAL ATTACH CLIP CRACKED AT FS 625 RIGHT STRINGER 14. C-CHECK, REPLACED CLIP PER REO.
SDR SWIA200820183Attach Fitting · crackedC-CHECK, INTERCOSTAL ATTACH CLIP CRACKED AT FS 625 LEFT STRINGER 14. REPLACED CLIP PER REO.
SDR SWIA200820182Floorbeam · crackedC-CHECK, UPPER FLANGE FS280 FLOORBEAM AT RBL12 CRACKED. REPAIRED PER REO.
SDR SWIA200819579Windshield · crackedFLT 6498 - FIRST OFFICERS WINDSHIELD IS CRACKED. REPLACED RIGHT WINDSHIELD IAW MM 56-11-01, P/N OFF 601R33033-14, S/N OFF 01230H5902.
SDR SWIA200819578Windshield · crackedFLT 6498 - CAPTAIN'S WINDSHIELD HAS SEVERAL SMALL CRACKS. REPLACED CAPTAIN'S WINDSHIELD IAW 56-11-01. OPS TEST GOOD, P/N 601R33033-13, S/N OFF 01183H2346.SDR SWIA200819384Hydraulic Line · leakingFLT 6025 - RECEIVED A "HYD 1 LOW PRESS" CAUTION MESSAGE. REPLACED NR 1 HYDRAULIC SYSTEM SUCTION LINE AS REQUIRED. NO LEAKS NOTED AT THIS TIME.SDR SWIA200819288Light · inoperativeFLT NR 1000, LEFT ENGINE FIRE BOTTLE "PUSH TO DISCHARGE" LIGHT WILL NOT ILLUMINATE. CLEANED AND RESEATED SWITCHLIGHT ASSEMBLY. OPS CHECK GOOD.
SDR SWIA200819222Connector · disconnectedREAR EMERGENCY LIGHTING STRIP IS INOP, FLIGHT NR 6046. SECURED AFT EMERGENCY LIGHT CONNECTORS AS REQUIRED. OPS CHECKS GOOD.
SDR SWIA200819039Pcu · inoperativeFLT 6500 - RIGHT ELEVATOR DOES NOT MOVE WITH HYDRAULIC SYSTEM 3 PRESSURIZED. REPLACED RIGHT NR 3 HYD ELEVATOR PCU IAW 27-33-01. OPS CHECK GOOD.
PN 27600-3, SN OFF 8783.SDR SWIA200718564Pump · leakingIN FLIGHT, HYDRAULIC SYSTEM NR 2 QUANTITY WENT TO ZERO. SYSTEM MAINTAINED 3000 PSI, FLIGHT NR 5873. REPLACED NR 2 ENGINE DRIVEN HYDRAULIC PUMP IAW CRJ 200 AMM 29-11-01. OPS AND LEAKS CHECKS GOOD, P/N 887055, S/N OFF MX659434.SDR SWIA200717872Line · leakingON LANDING, LOST ALL HYD FLUID IN NR 2 SYSTEM. REPAIRED NR 2 ENGINE CASE DRAIN RETURN LINE IN AFT EQUIPMENT BAY IAW CRJ MM 20-22-00. OPERATIONAL CHECKS GOOD.SDR SWIA200617317Web · crackedPAX DOOR WEB CRACKED BEHIND AFT HANDRAIL SUPPORT, DISCOVERED DURING C-CHECK INSPECTION. INSTALLED REPAIR PARTS ON AFT SIDE OF PAX DOOR PER REO 601R-52-11-702.SDR SWIA200617316Web · crackedPAX DOOR UPPER WEB CRACKED (2) LOCATIONS, UNDER TOP FOLDING STEP, DISCOVERED DURING C-CHECK INSPECTION. INSTALLED 2 REPAIR ANGLES AND 2 FILLERS IAW REO NR 601R-52-11-279.SDR SWIA200617315Bracket · crackedPULLEY BRACKET CRACKED STATION 484 RBL36, DISCOVERED DURING C-CHECK INSPECTION. REPLACED CLIP AT STA 484 RBL 36 AND INSTALLED REPAIR ANGLE PER REO 601R 53-41-059.SDR SWIA200617314Web · crackedPAX DOOR AFT WEB CRACKED 4TH STEP FROM BOTTOM, DISCOVERED DURING C-CHECK INSPECTION. INSTALLED DOUBLER, REPAIR ANGLE AND FILLERS AS PER REO 601R-52-11-1108.SDR SWIA200617313Doubler · crackedRT FS 640.00 BETWEEN STRINGERS 9 AND 12 ENG BEAM REINFORCEMENT DOUBLER CRACKED, DISCOVERED DURING C-CHECK INSPECTION. INSTALLED NEW REINFORCEMENT DOUBLER AT FS 640.00 RT BETWEEN STRINGER 9 AND 12 IAW CRJ200 SRM 51-40-11.SDR SWIA200516006Control Unit · malfunctionedFLT SPOILERS FAULT STATUS MSG ON APPROACH INTO DEN. REPLACED BOTH NR 1 AND NR 2 SECU'S IAW AMM 27-61-05. OPERATIONAL CHECK GOOD, PN 49-164-05, SN/OFF 01428, PN 49-164-05, SN/OFF 01427.SDR SWIA200515636Windshield · failedFO SIDE WINDOW SHATTERED AT FL350. REPLACED RT SIDE WINDOW IAW CRJ 200 MM 56-12-01. OPERATIONAL CHECK GOOD, PN OFF NP139322-6, SN OFF 02058H9575.SDR SWIA200515542Detector · malfunctionedFLAP DEGRADED STATUS MESSAGE WILL NOT CLEAR. REPLACED SKEW DETECTION SYSTEM UNIT IAW MM CHATPER 27-51-15. OPERATIONAL CHECK GOOD. P/N 601R59014-1; S/N OFF A-289.