N925AE
Service difficulty reports · 199
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N925AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N925AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA20190507007Attach Fitting · crackedRT LOWER WING TO FUSELAGE ATTACHMENT ANGLE NR 2 IS CRACKED ON THE AFT EDGE APPROX. 4" LONG. C/A-REMOVED AND REPLACED LOWER WING TO FUSELAGE ATTACHMENT ANGLE NR 2 IAW ETN-EM-53-142 AND SRM 51-40-02.SDR SIMA20190507006Attach Angle · crackedLT LOWER WING TO FUSELAGE ATTACHMENT ANGLE NR 3 IS CRACKED ON THE FWD EDGE APPROX. 3/4" LONG. C/A-RAR ATTACHMENT ANGLE NR 3 IAW ETN-EM-53-142.SDR SIMA20190426006Crease Beam · corrodedCORROSION ON RIGHT HAND CREASE BEAM AFT OF FRAME 22. C/A-COMPLETE:REMOVED AND REPLACED RIGHT HAND CREASE BEAM AFT OF FRAME 22 IAW SRM 51-40-02.SDR SIMA20190426005Structure · cracked#1 THROUGH #8 RT SIDE EMERGENCY LIGHT FLOOR EXTRUSIONS ARE CRACKED. C/A-COMPLETE:REPLACED #1 THROUGH #8 RT SIDE EMERGENCY LIGHT FLOOR EXTRUSIONS IAW AMM 33-50-12.SDR SIMA20190426004Light · inoperative#3 EMERGENCY FLOOR LIGHT STRIP IS INOP. C/A-COMPLETE:INSTALLED A NEW EMERGENCY LIGHT STRIP #3, OPS CHECK GOOD, WORK DONE IAW AMM 33-50-12.SDR SIMA20190426003Wire · broken#5 AND #8 LT FLOOR EMERGENCY LIGHTS HAVE BROKEN WIRES. C/A-COMPLETE:INSTALLED NEW LT FLOOR EMERGENCY LIGHTS AT LOCATONS #5 AND #8. OPS CHECK GOOD IAW AMM 33-50-12.SDR SIMA20190426002Channel · corrodedRT HAT BEAM JUST AFT OF FRAME 59 IS CORRODED AROUND NUTPLATE HOLE. C/A-REPAIRED RT HAT BEAM JUST AFT OF FRAME 59 IAW SRM 53-24-10.SDR SIMA20190129003Carbon Seal · leakingSTRONG OIL SMELL WHEN LT BLEED SELECTED ON IN FLT DECK. NO SMELL IN CABIN. WHEN LT BLEED SELECTED CLOSED, NO OIL SMELL DETECTED. STRONGEST ODOR WHEN PWR LEVERS MOVED. PERFORMED BOROSCOPE PER RRMM 72-00-00 POSSIBLE NUMBER ZERO CARBON SEAL LEAKING. REF NRWC 925-SDR SIMA20190111005Muffler · dirtySMELL OF MUSTY SOCKS THROUGHOUT AIRCRAFT DURING FLIGHT. C/A-T/S IAW FIM TASK 21-20-00 AND FOUND LT RECIRCULATION SYSTEM MUFFLER SCREEN TO BE DIRTY. CLEANED LT RECIRCULATION SYSTEM MUFFLERS IAW AMM 21-42-02. PERFORMED OPC OF LT AND RT PACKS IAW AMM 36-00-00 ANSDR SIMA20190111003Light · inoperativeFLOOR EMERGENCY LIGHT AT SEAT 14-16 INOP. C/A-REMOVED AND REPLACED FLOOR EMERGENCY LIGHT AT SEAT 14-16, OPC GOOD, IAW AMM 33-50-12SDR SIMA20190102001Light · inoperative12BC OVER HEAD EMERGENCY LIGHT INOP. C/A-REMOVED AND REPLACED SEAT 12BC AISLE EMERGENCY LGHT LAMP IAW AMM 33-50-08-000-801-A AND 33-50-08-400-801-A. OPC GOOD, NO FURTHER DEFECTS NOTED. END.SDR SIMA2018123128002Battery Pack · unsecureLH AND RH OVERWING EXIT AREA EMERGENGY LIGHTS INOP-C/A-REMOVED FLOOR BOARD PANEL FOUND BATTERY PACK NOT INSTALLED. INSTALLED AND SECURED BATTERY PACK TO HOLDER AND REINSTALLED FLOOR BOARD IAW EMB 145 AMM 33-50-04 STEPS 4,I,4,B. 5,I(1,2,3). J,3,B. 6. OPC CHECK SDR SIMA201812108001Battery Pack · failedDURING PS-1 CHECK, FOUND LEFT AND RIGHT EXTERIOR OVER THE WING EMERGENCY LIGHTS OUT.-C/A-CHANGED #4 EMERGENCY BATTERY IAW AMM TASK 33-50-04 DID NOT FIX ISSUE. OVER WING LH AND RH EMERGENCY LIGHTS DEFERRED PER MEL 33-29 AUTH 120313D-C. EMERGENCY LIGHTING BATTERSDR SIMA201811276004Charger · failedLH AND RH OVERWING EMERGENCY LIGHTS INOP-C/A-REMOVED AND REPLACED #4 EMERGENCY LIGHT BATTERY AND CHARGER IAW ENVOY MTX WC 33-700-19, OPC AND FUNCTIONAL CHECK GOOD. EMERGENCY LIGHTING BATTERY P/N 2013-1A S/N 79268SDR SIMA201808232002Controller · faultedIN CLIMB ON TAKE OFF MANUAL SYSTEM WOULD NOT PRESSURIZE THE AIRCRAFT CABIN PRESSURE GOT UP TO 9500. REMOVED AND REPLACED THE MANUAL PRESSURE CONTROLLER IAW EMB 145 AMM 21-31-02. MANUAL PRESURIZATION CONTROL OPS CHECK GOODSDR SIMA201808221002Controller · failedIN CRUSE @ FL 340 PRESN AUTO FAIL CAUTION MSG APPEARED RAN CHECK LIT BUT PRESSURIZATION NEVER STABILIZED PER LOSSS OF PRESSERIZATION INDICATION TABLE CAB RATE RANGED FROM -900 TO 2800 FPM AT 10000 FT MSL INDICATION ON MFD CAB ALT ON EICAS SHOWED AMBER DASHES WSDR SIMA2018082019006Wheel · vibrationNOSE WHEEEL VIBRATION AT HIGH SPEED. REMOVED AND REPLACED NLG WHEEL AND TIRE ASSYS IAW 32-700-17SDR SIMA2018073130004Light · inoperativeLT OVERWING EMERGENCY EXIT LT INOP AT SEAT 12A. REMOVED AND REPLACED LT OVERWING EMERGENCY LAMP (12A PSU PANEL) IAW AMM 33-50-07-000-801-A/33-50-07-400-801-A OPC GOOD.SDR SIMA20180601002Door · obstructedPASSENGER MAIN DOOR HARD TO OPEN, FOUND TRIM PIECE AROUND DOOR ON AFT SIDE LOOSE AND CRACKED. SECURED THE TRIM PIECE. FOUND NO DEFECTS ON MAIN DOOR TRIM. MAIN DOOR LINER WAS REPLACED.SDR SIMA20180522002Handle · looseMAIN CABIN DOOR WAS VERY DIFFICULT TO OPEN. INSPECTED AND FOUND MAIN DOOR INTERNAL HANDLE LOOSE. TIGHTENED AND OPS CHECK IAW AMM 52-18-00-820-801-A. OPS CHECK GOOD.SDR SIMA20180406003Battery Pack · inoperativeRT & LT OVERWING EMERGENCY LIGHTS INOPERATIVE. NR 4 BATTERY POWER SUPPLY REMOVED AND REPLACED IAW AMM 33-50-04. OPS CHECKED GOOD.SDR SIMA201803210001Proximity Sensor · failedA LOUD BANG SOUND WHEN ENERGIZING EITHER HYDRAULIC SYSTEMS NR 1 OR 2. INSPECTED AND FOUND THE LANDING GEAR FREE FALL CONTROL CABLE WRAPPED AROUND THE NLG UPLOCK BOX. REMOVED AND REPLACED THE RT NLG DOWNLOCK AND RT MLG FORWARD DOWNLOCK PROXIMITY SWITCHESDR SIMA20180314008Battery · dischargedLT AND RT OVERWING EMERGENCY LIGHTS INOP. R&R NR 4 EMERGENCY BATTERY IAW WORK CARDS 33-700-19 AND 33-700-17 OPS CHECK GOOD AT THIS TIME END.SDR SIMA20171214001Anti-Ice Valve · failedE1 A/ICE FAIL. DURING CLIMB CAUTION MSG KEPT APPEARING. E1 WOULD NOT OPEN WHEN OVERRIDE SET TO ALL DURING CHECKLIST AND DURING ICE TEST E1 WOULD NOT OPEN. ICE TEST FAILED. E2 A/ICE FAIL MSG APPEARED AFTER E1 A/ICE FAIL DURING CLIMB-C/A-ITEM DEFFERED AS PER 30-SDR SIMA20171211003Battery Pack · inoperativeEMERGENCY EXIT LIGHTS OVER THE WINGS INOP-C/A-REMOVED AND REPLACED FUSE ON #4 EMERGENCY BATTERY IAW RADIANT CMM 25-60-03 AND EMB AMM 33-50-00.OPS TEST OF EMERGENCY LIGHTS GOOD.NO OTHER DEFECTS NOTED AT THIS TIME.SDR SIMA20171116003Relay · failedDURING FLIGHT, THREE TIMES IN ICING CONDITIONS, ONCE DURING CLIMB AND TWICE ON APPROACH, RECEIVED AN ANTI ICE INOPERATIVE WARNING. ALL 4 OPEN INSCRIPTIONS FOR ICE PROTECTION ON OVERHEAD PANEL AND THE BLEED TEMPS AND MARKERS NORMAL ON THE ECS PAGE. IAW NRWC 9SDR SIMA20171112002Duct · crackedANTI ICE INOPERATIVE DURING CLIMB. TROUBLESHOT IAW FIM 30-80-00-810-801-A. NO FAULTS FOUND. INSPECTED ANTI-ICE VALVE, FOUND A CRACKED DUCT. REMOVED AND REPLACED THE DUCT IAW AMM 36-11-09. OPS CHECKED GOOD.SDR SIMA20170122005Wire · brokenEMERGENCY STRIP LIGHT STRIP NR 1 IN GALLEY HAS BROKEN WIRE. R&R EMERGENCY LIGHT STRIP ASSY IN GALLEY IAW AMM 33-50-12.SDR SIMA20170120005Connector · brokenEMERGENCY LIGHT STRIP ASSY NR 5 HAS BROKEN CONNECTOR. REPLACED EMERGENCY LIGHT STRIP NR 5 IAW SWPM 20-00-03 AND SWPM 20-21-00.SDR SIMA20170116004Skin · crackedFUSELAGE SKIN CRACKED AFT OF FR75 AND ABOVE STR 2L. PERFORMED PERMANENT REPAIR OF FUSELAGE SKIN AFT OF FR75 AND ABOVE STR2L IAW SRM 53-31-0.1SDR SIMA20170115003Fitting · damagedRT AILERON DAMPENER FITTING HAT BUSHING HOLES ELONGATED. REMOVED AND REPLACED RT AILERON DAMPENER FITTING IAW EO-EM-27MR-112.SDR SIMA20170115004Fitting · damagedRT AILERON PCA FITTING HAT BUSHING HOLES ELONGATED. REMOVED AND REPLACED RT AILERON PCA FITTING IAW EO-EM-27MR-112.SDR SIMA20161022002Flashlight · inoperativeAFT FA FLASHLIGHT INOPERATIVE. REMOVED AND REPLACED AFT CABIN FLASHLIGHT IAW AMM 33-50-16. OPS CHECKED GOOD.SDR SIMA20160928006Flashlight · inoperativeFO'S FLASHLIGHT INOP. REMOVED REPLACED FO'S FLASHLIGHT. OPERATIONAL TEST GOOD IAW CMM 25-60-02 MEL RESTOREDSDR SIMA20160902002Light · inoperativeRIGHT OVERWING EXTERIOR EMERGENCY LIGHT INOPERATIVE. R & R RT OVERWING EXTERIOR EMERGENCY LAMP. OPS CHECK GOOD IAW AMM 33-50-10.SDR SIMA20160513002Fitting · looseSIGNIFICANT SPLIT BETWEEN ITT RT ENG, 40 - 70 DEGREES HOTTER THAN LT. INSPECTED NR 2 ENG BLEED SYS DUCTING. FOUND NR 2 ENG COMPRESSOR ACCELERATION BLEED VLV FITTING LOOSE & CROSS THREADED. REPAIRED IAW EO EM 7500-001R2. OPERATIONS CHECKED GOOD AT THIS TIMESDR SIMA20151114001Sensor · failedBRAKE OVERHEAT ON EICAS AFTER TAKEOFF, RT INBD INDICATOR IN AMBER, COMPLIED WITH AOM VOL 1. PROCEDURES RETURNED, NOT AN OVERWEIGHT LANDING SINK RATE 300FT PER MIN. DEFERRED RT INBD BRAKE INDICATION. R & R BRAKE TEMP SENSOR IAW AMM 32-47-01. OPERATIONS CHECSDR SIMA20150808001Holder · brokenCAPTAINS FLASHLIGHT HOLDER BROKEN. R & R CAPTAINS FLASHLIGHT HOLDER IAW AMM 33-50-16. OPERATIONS CHECKED GOOD.SDR SIMA20150123006Light · inoperativeSERVICE DOOR EXTERNAL EMER LAMP INOPERATIVE. R & R SERVICE DOOR EXTERNAL EMER LAMP IAW AMM 33-50-09-000-801-A & 33-50-09-400-801-A. OPERATIONS CHECKED GOOD.SDR SIMA20141206004Skin · crackedRIGHT UPPER FUSELAGE SKIN CRACKED JUST AFT OF FRAME 75 & ABOVE STRINGER 2R. CRACK ENDS MARKED APPROX 3/8 INCHES IN LENGTH. DO NOT STRIP FOR NDT. EASI 8071 USED, FREQ=400KHZ, VGAIN=77, HGAIN=65, LPF=100. ACCOMPLISHED REPAIR ON RT UPPER FUSELAGE SKIN JUST AFSDR SIMA20141205002Frame · gougedAFT SIDE FRAME 53 GOUGED. ACCOMPLISHED AFT SIDE FRAME 53 REPAIR IAW ERS-EM-53MR-932.SDR SIMA20141204006Wire · brokenCABIN LT EMER LIGHT STRIP NR 1 HAS ONE EACH BROKEN WIRE. REPAIRED THE CABIN LT EMER LIGHT STRIP NR 1 ONE EACH WIRE IAW SWPM 20-21-00, FOUND DURING INSPECTION.SDR SIMA20141204008Door Frame · corrodedFORWARD SERVICE DOOR FRAME CORRODED ON PREVIOUSLY BLENDED AREA AROUND LOWER NUTPLATE HOLE. ACCOMPLISHED REPAIR ON FWD SERVICE DOOR FRAME IAW ERS-EM-53MR-930.SDR SIMA20141204007Wire · brokenCABIN LT EMER LIGHT STRIP NR 7 HAS ONE EACH BROKEN WIRE. REPAIRED THE CABIN LT EMER LIGHT STRIP NR 7 ONE EACH WIRE IAW SWPM 20-21-00, FOUND DURING INSPECTION.SDR SIMA20141118004Return Line · failedTHE RETURN LINE CHECK VLV OF THE EMER PARKING BRAKE FAILED. OPERATIONS CHECKED. R & R EMER PARKING BRAKE RETURN LINE CHECK VLV. PERFORMED LEAK CHECK & BLED HYD SYS IAW AMM 32-44-08.SDR SIMA20141112002Unknown · odorFLIGHT ATTENDANT COMPLAINED OF SMELL IN CABIN DURING CRUISE SMELL LESSENED WHEN PACK ONE WAS DESELECT OFF. PERFORMED GND RUN PACK ONE FOR 20 MINUTES IAW AMM 21-00-00, NO SMELL NOTED.SDR SIMA20140906002Unknown · malfunctionedFIRST OFFICER`S PFD LOST AIR DATA ON APPROACH AFTER FLIGHT THROUGH PRECIPITATION. PERFORMED PITOT STATIC SYS 2 LEAKAGE TEST IAW AMM 34-13-00. OPERATIONS CHECKED GOOD. ACFT IS COMPLIANT FOR CAT II OPERATIONS.SDR SIMA20140731001Smoke Detector · false activationSUPPLEMENTAL BAGG SMOKE EICAS WARNING DURING TAXI. CFR SAID THEY SMELLED BURNING ELECTRICAL SMELL COMING FROM CARGO COMPARTMENT-C/A-DEFERRED PER MEL 26-09. AUTH # 071338D-C. CORRECTIVE ACTION: REMOVED AND REPLACED RELAYS K0625, K0629, K0630. SMELL WAS NOTED ASSDR SIMA20140623001Battery · dischargedLT & RT OVERWING EMER LIGHTS INOPERATIVE. DEFERRED IAW MEL 33-29. R & R NR 4 EMER LIGHT BATTERY POWER SUPPLY IAW AMM 33-50-04, OPERATIONS CHECKED GOOD. MEL ITEM IS RESTORED.SDR SIMA20140211003Cradle · brokenAFT FLIGHT ATTENDANT`S FLASHLIGHT CRADLE BROKEN. R & R AFT FLIGHT ATTENDANT`S FLASHLIGHT & CRADLE IAW 33-50-16, OPERATIONS CHECKED GOOD.
Back to N925AE