N930SW
Service difficulty reports · 233
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N930SW' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N930SW' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWIA200819618Switch · failedFLT 5932 - WHITE SMOKE BEGAN TO FILL THE FLIGHT DECK WHILE AT THE GATE. REPLACED ACM HI TEMPERATURE SWITCH PER AMM 21-51-25. OPS CHECK GOOD.
SDR SWIA200819601Support · crackedFLT 6043 - EXTERNAL POWER RECEPTACLE SUPPORT MEMBER IS CRACKED. REPLACED EXTERNAL POWER RECEPTACLE SUPPORT MEMBER PER REO 601R53-11-009 AND REO 601R53-11-1391.SDR SWIA200819135Window · crackedRIGHT SIDE WINDOW CRACKED ON APPROACH. REPLACED RIGHT SIDE WINDOW IAW MM 56-12-01, P/N OFF: NP139322-6W, S/N OFF: 02262R6245.
SDR SWIA200718817Drive Unit · faultyFLT 6133 - RIGHT REVERSER UNLOCK MESSAGE INFLIGHT. REPLACED PNEUMATIC DRIVE UNIT PER CRJ 200 MM 78-32-03. OPS CHECK GOOD, P/N: 126758-7, S/N OFF: 2178.
SDR SWIA200718383Frame · crackedSTA 640 RIGHT SIDE FRAME REINFORCEMENT DOUBLER IS CRACKED, DISCOVERED AT C-CHECK. INSTALLED STA640 RIGHT SIDE FRAME DOUBLER PER CRJ200 SRM 51-42-06 AND 51-42-21.SDR SWIA200718382Frame · crackedSTA 640 LEFT FRAME REINFORCEMENT DOUBLER IS CRACKED, DISCOVERED AT C-CHECK. INSTALLED NEW STA640 FRAME DOUBLER PER CRJ SRM 51-42-06/51-42-21.SDR SWIA200718381Floorbeam · crackedFS 280 FLOOR SUPPORT BEAM IS CRACKED AT RBL9, DISCOVERED AT C-CHECK. REPAIRED LOWER SUPPORT BEAM AND INBOARD OUTBOARD CLIPS AT FS 280 RBL9 PER CRJ200 REO 601R-53-11-171 REV "C".SDR SWIA200718380Floorbeam · crackedFS 280 FLOOR SUPPORT BEAM IS CRACKED AT LBL9, DISCOVERED AT C-CHECK. INSTALLED INBOARD AND OUTBOARD CLIPS AT LBL9 FS280 FLOOR SUPPORT AND REPAIR ANGLE PER CRJ200 REO 601R53-171 REV C.SDR SWIA200718379Support Beam · crackedENGINE SUPPORT BEAM RIGHT LOWER WEB IS CRACKED, DISCOVERED AT C-CHECK. INSTALLED REPAIR DOUBLER, WEB FILLER, SHIM, STRAP AND ANGLE PER CRJ200 REO 601R 53-61-358 REV A.SDR SWIA200718378Beam · crackedENGINE SUPPORT BEAM LEFT LOWER WEB CUTOUT IS CRACKED, DISCOVERED AT C-CHECK. INSTALLED REPAIR FILLER, DOUBLER, SHIM AND ANGLE ON LOWER LEFT WEB PER CRJ200 REO 601R 53-61-358 REV A PG 1-4.SDR SWIA200718377Beam · crackedENGINE SUPPORT BEAM UPPER WEB FOUND TO BE CRACKED AT STA 640 AND RBL 8, DISCOVERED AT C-CHECK. INSTALLED UPPER DOUBLER, FILLER, SHIMS, AND ANGLES PER REO 601R-53-61-345 REV D.SDR SWIA200617448Lamp · inoperativeNR 2 EMERGENCY LIGHT ON LEFT EXTERIOR AND NR 3 EMERGENCY LIGHT ON RIGHT EXTERIOR ARE INOP. RELAMPED BOTH EMERGENCY LIGHTS IAW AMM 33-50. OPERATIONAL CHECK GOOD.SDR SWIA200617353Window · crackedCAPTAIN'S FORWARD WINDOW HAS CRACK IN IT. REPLACED CAPTAIN'S FORWARD WINDOW IAW AMM 56-11-01, AND RII CARD 56-220-1000, PN NP-139321-13, SN OFF 02183119418.SDR SWIA200616437Computer · malfunctionedSTALL FAIL CAUTION CLIMBING THROUGH FL320 UP TO FL350 AND ALL THE WAY TO LANDING. REPLACED STALL PROTECTION COMPUTER REF AMM 27-35-01 OPERATIONAL CHECK GOOD, PN 3995100208, SN/OFF 946.SDR SWIA200516316Floorbeam · crackedFS 621.00, LBL 40, FLOORBEAM ANGLE IS CRACKED, ITEM FOUND AT C-CHECK INSPECTION. REPAIRED IAW CRJ REO 601R-53-61-117 REV C.SDR SWIA200516315Clip · crackedFS 625.00 AT STRINGER 14L ATTACH CLIP CRACKED, ITEM FOUND AT C-CHECK INSPECTION. REPAIRED IAW CRJ REO 601R-53-61-422 AND REO 601R-53-61-100.SDR SWIA200516314Intercostal · crackedFUSELAGE, PULLEY INTERCOSTAL HAS CRACKED I/B ANGLE FS 484.00; LBL 27.0, ITEM FOUND AT C-CHECK INSPECTION. ANGLE REPLACED IAW CRJ REO 601R-53-41-059 REV A.SDR SWIA200516313Floorbeam · crackedFS 280.00 AT RBL 9, O/B FLOORBEAM ATTACH ANGLE IS CRACKED, ITEM FOUND AT C-CHECK INSPECTION. REPAIRED IAW CRJ SRM 51-22-00, 51-42-21, 51-41-02, 51-21-11, 51-40-11 PARA 4.SDR SWIA200516312Clip · crackedFS 625.00 AT STRINGER 14R ATTACH CLIP CRACKED, ITEM FOUND AT C-CHECK INSPECTION. REPAIRED IAW CRJ REO 601R-53-61-442 AND REO 601R-53-61-100.SDR SWIA200516311Floorbeam · crackedFS 280.00 AT LBL 9 - O/B FLOORBEAM ATTACH ANGLE IS CRACKED, ITEM FOUND AT C-CHECK INSPECTION. REPAIRED ATTACH ANGLE IAW CRJ 51-22-00, 51-42-21, 51-41-02, 51-21-11 AND 51-40-11 PARA 4.SDR SWIA200516310Floorbeam · crackedFS 280.00 AT RBL 9 , I/B FLOORBEAM ATTACH ANGLE IS CRACKED, ITEM FOUND AT C-CHECK INSPECTION. REPAIRED IAW CRJ SRM 51-22-00, 51-42-21, 51-41-01, -51-21-11, 51-40-11 PARA 4.SDR SWIA200515667Actuator · malfunctionedFLAPS FAILED AT 30 DEGREES ON FINAL FOR LANDING. REPLACED RT NR 1 AND NR 2 FLAP ACTUATORS IAW MM 27-53-05. OPERATIONAL CHECK GOOD, PN 852D100-19 SN/OFF 4194, PN 852D100-19 SN/OFF 4272.SDR SWIA200515593Control Unit · malfunctionedFLAPS FAIL CAUTION MESSAGE. REPLACED FECU. OPERATIONAL CHECK GOOD IAW CRJ MM 27-51-05.SDR SWIA200515554Bpsu · malfunctionedFLAPS HALFSPEED STATUS MSG. REPLACED RIGHT BPSU IAW AMM 27-51-10, OPERATIONAL CHECK GOOD.SDR SWIA200515483Smoke Detector · intermittentFWD CARGO SMOKE DETECTOR RED LIGHT STAYS ON AND INTERMITTENTLY GIVES WARNING. REPLACED CARGO BAY FORWARD SMOKE DETECTOR REF AMM 26-15-01. OPERATIONAL CHECK GOOD.SDR SWIA200515419Sensor · malfunctionedFLAPS FAIL MSG DURING AFTER LANDING. REPLACED RT FLAP BPSU. OPERATIONAL CHECK GOOD IAW CRJ 200 AMM 27-51-10.SDR SWIA200515033Light · brokenMAIN CABIN DOOR EMERGENCY EXIT LIGHT BROKEN. REPAIRED LIGHT ASSY AS REQUIRED. OPERATIONAL CHECK GOOD.SDR SWIA200514943Battery Pack · inoperativeEMERGENCY EXIT LIGHT FLOOR AND PART OF OVERHEAD SYSTEMS INOPERATIVE. REPLACED NR 2 AND NR 4 EMERGENCY LIGHT BATTERY PACKS. OPERATIONAL CHECK GOOD.SDR SWIA200413861Control Panel · malfunctionedSTAB TRIM AND MACH TRIM CAUTION MESSAGES CAME ON TWICE DURING FLIGHT. REPLACED STAB TRIM/MACH TRIM CONTROL PANEL WITH SERVICEABLE UNIT. OPERATIONAL CHECK GOOD IAW MM 27-00-00.SDR SWIA200413706Wire · brokenRUDDER TRIM WILL NOT MOVE NOSE RIGHT. REPAIRED BROKEN WIRE AT RUDDER TRIM SWITCH IAW CRJ WM CHAPTER 20-10-00. OPERATIONAL CHECK GOOD.SDR SWIA200413647Floor Support · crackedFLOOR SUPPORT STRUCTURE, RIGHT SIDE 621 ANGLE IS CRACKED. ITEM FOUND AT C-CHECK INSPECTION. INSTALLED REPAIR PARTS ON RIGHT SIDE 621 ANGLE IAW BOMBARDIER REO 601R-53-61-117.SDR SWIA200312393Pcu · malfunctionedDURING FLIGHT WE RECEIVED (FLT SPOILER FAULT) MESSAGE ON FLT CONTROL PAGE INDICATED WITH A WHITE RT FLIGHTER SPOILER. WE HAD TO USE 20 PERCENT LEFT AILERON, TRIM AND RT RUDDER TRIM TO TRIM A/C. REPLACED RT IB FLIGHT SPOILER PCU. OPS CHECKS GOOD. NO LEAKS NSDR SWIA200311950Computer · malfunctionedIAPS DEGRADED STATUS MESAGE WOULD NOT CLEAR. REMOVED AND REPLACED NR 2 DCU IAW CRJ MM 31-41-04. OPS CHECK GOOD PER CRJ MM 31-41-00.
Back to N930SW