SDR REXA2013120702219Control Valve · malfunctionedDURING PUSHBACK WE RECEIVED A LT PACK AUTO FAIL CAUTION ASSOCIATED WITH AN ODOR. WE SHUT OFF LT PACK & ODOR WENT AWAY & CAUTION WENT AWAY IN ABOUT 5 MINUTES. IAW MEL 21-51-1 B. ENTERED IN MM2 MC ADVICES PLACARD INSTALLED. R & R TEMP CONTROL VLV IAW AMM 21-Dec 7, 2013 · N932XJ · Cndair CL6002D24 · Cabin Cooling SystemSDR REXA2013113002201Lens · missingCENTER OVERHEAD AISLE EXIT SIGN FWD SIDE MISSING BLUE & RED LENS CAPS. LENS CAPS DEFERRED IAW NEF N33-50-1. TRANSFERRED TO MMO2 CTRL 2348532-1, NOTIFIED MOC 53212 CAT E 90 DAYS.Nov 30, 2013 · N932XJ · Cndair CL6002D24 · Emergency LightingSDR REXA2013112802195Flashlight · inoperativeEMERGENCY FLASHLIGHT IN GALLEY BY SERVICE DOOR INOPERATIVE. R & R FLASHLIGHT IAW AMM 25-61-02.Nov 28, 2013 · N932XJ · Cndair CL6002D24 · Emergency EquipmentSDR REXA2013101902070Light · unsecureFLOOR TRACK LIGHTING NEAR 13C IS DETACHED. SECURED EMERGENCY FLOOR TRACK STRIP AT 13C IAW AMM 33-51-01.Oct 19, 2013 · N932XJ · Cndair CL6002D24 · Emergency LightingSDR REXA2013101702112Light · missingEMERGENCY LIGHT MISSING. REPLACED MISSING EMERGENCY LIGHT IAW 33-51-01. OPS CHECKED GOOD.Oct 17, 2013 · N932XJ · Cndair CL6002D24 · Emergency LightingSDR REXA2013041700516Cooling Fan · failedDURING CRUISE STARTED SMELLING ELECTRIC BURN SMELL AFTER ABOUT 20 MINS WE HEARD THE AVIONICS FAN GRINDING AND COMING TO A STOP FOLLOWED BY THE AVIONICS COOL FAN CAUTION MESSAGE BEING DISPLAYED. FOLLOWED THE NON-NORMAL CHECKLIST, MESSAGE WENT AWAY. IT APPEAREApr 17, 2013 · N932XJ · Cndair CL6002D24 · Air Distribution FanSDR REXA2013032600458Structure · corroded280 CIRCUMFERENTIAL JOINT CORRODED BETWEEN STR 26L AND 26R. A251-048. REPAIRED 280 CIRCUMFERENTIAL JOINT BETWEEN STR 26L AND STR 26R IAW CRJ900 REO# 690-53-21-443 AND EO#R53317.Mar 26, 2013 · N932XJ · Cndair CL6002D24 · Fuselage Miscellaneous StructureSDR REXA2013032600457Doubler · corrodedLOWER VHF ANTENNA DOUBLER CORRODED BETWEEN FS 295 AND FS 310. REMOVED CORROSION LWR VHF ANTENNA BETWEEN FS 295 & FS 310. FOUND WITHIN LIMITS IAW CRJ900 SRM 51-21-06. EO#R53277.Mar 26, 2013 · N932XJ · Cndair CL6002D24 · Fuselage Main, Plate/SkinSDR REXA2013032600456Splice · corroded280 CROSSBEAM SPLICE IS CORRODED. A251-051. REMOVED AND REPLACED 280 CROSSBEAM SPLICE IAW CRJ900 SRM 51-42-06. P/N CC670-34095-35.Mar 26, 2013 · N932XJ · Cndair CL6002D24 · Fuselage Miscellaneous StructureSDR REXA2013032600455Crossbeam · corrodedLEFT 280 CROSSBEAM CORRODED A251-053. REMOVED AND REPLACED LEFT FS 280 BEAM IAW EO R53315&R53127 & R53117.Mar 26, 2013 · N932XJ · Cndair CL6002D24 · Fuselage Miscellaneous StructureSDR REXA2013032600454Crossbeam · corrodedRIGHT 280 CROSSBEAM CORRODED A251-053. REMOVED AND REPLACED RIGHT FS 280 BEAM IAW EO#R53158&R53127 & R53117. P/N CC670-34094-25.Mar 26, 2013 · N932XJ · Cndair CL6002D24 · Fuselage Miscellaneous StructureSDR REXA2013032600453Structure · crackedLBL 12 CRACKED JUST FWD OF 280 BEAM. REPAIRED LBL 12 BEAM IAW EO#R53314.Mar 26, 2013 · N932XJ · Cndair CL6002D24 · Fuselage Miscellaneous StructureSDR REXA2013032600452Structure · crackedRBL 12 CRACKED JUST FWD OF 280 BEAM. REPAIRED RBL 12 BEAM IAW EO#R53314.Mar 26, 2013 · N932XJ · Cndair CL6002D24 · Fuselage Miscellaneous StructureSDR REXA2013032600451Structure · crackedFWD EQUIPMENT BAY FLOOR IS CRACKED IN CORNER CUTOUT AT FS 193.00 RIGHT SIDE. REPAIRED FWD EQUIPMENT BAY FLOOR CORNER CUTOUT AT FS 193.00 RIGHT SIDE IAW EO #R53316.Mar 26, 2013 · N932XJ · Cndair CL6002D24 · Fuselage Miscellaneous StructureSDR REXA2013031900313Battery Pack · dischargedALL THREE CEILING PANEL EMERGENCY LIGHTS AFT OF OVERWING EXIT DOORS AND BOTH RT AND LT AFT OF WING EMERGENCY EXTERIOR LIGHTS FAIL TO STAY ON. REMOVED AND REPLACED EMERGENCY BATTERY PACK 4 IAW CRJ900 AMM 33-51-17. OPS TEST S/W OF EMERGENCY LIGHTS IAW CRJ900 AMar 19, 2013 · N932XJ · Cndair CL6002D24 · Emergency LightingSDR REXA2013010700004Light · looseTHERE IS A LOOSE FLUORESCENT STRIP AROUND EMERGENCY EXIT ROWS 12CD. RE-INSTALLED FLUORESCENT TRACK STRIP FOR SEAT 12CD IAW CRJ900 AMM 33-51-01. OPS CHECK GOOD.Jan 7, 2013 · N932XJ · Cndair CL6002D24 · Emergency LightingSDR REXA2012122901603Flashlight · missingMISSING YELLOW FLASHLIGHT FROM FLT DECK. COCKPIT YELLOW FLASHLIGHT DEFERRED PER MEL 25-61-4A. ENTERED INTO MM02 MXOC NOTIFIED. PLACARD INSTALLED. REPLACED BATTERY POWERED FLASHLIGHT, FLIGHT DECK AS REQUIRED. PLACARD REMOVED, REMOVED FROM MM02, MXC NOTIFIEDec 29, 2012 · N932XJ · Cndair CL6002D24 · Emergency EquipmentSDR REXA2012062600936Light · damagedINSPECTION OF THE EMERGENCY FLOOR TRACK LIGHTING IN THE FORWARD GALLEY AREA FOUND DAMAGED. REMOVED AND REPLACED BOTH SIDES, IN FRONT OF GALLEY CARTS IAW MM 33-51-01.Jun 26, 2012 · N932XJ · Cndair CL6002D24 · Emergency LightingSDR REXA2012062100934Light · looseCREW REPORTED FLOOR TRACK LIGHT STRIP IN GALLEY LOOSE. REPLACED DAMAGED SECTION OF FLOOR TRACK LIGHT PER AMM 33-51-01.Jun 21, 2012 · N932XJ · Cndair CL6002D24 · Emergency LightingSDR MALA110177Skin · dentedLT AFT FUSELAGE DENTED 6 FT AFT OF CARGO DOOR AND 36 INCHES BELOW LT ENGINE NACELLE. DENT IS APPROX .7500 TO 1 INCH IN DEPTH AND 8 INCHES IN DIAMETER. RIVETS ARE POPPED AND OTHERS STRESSED. REPAIRED FUSELAGE SKIN AND STRINGER AT FS 1108-1098, STRINGER 14L -Aug 1, 2011 · N932XJ · Cndair CL6002D24 · Fuselage Main, Plate/SkinSDR MALA110176Skin · gouged1 INCH LONG VERTICAL GOUGE ON EXTERNAL SKIN AT FS 1047.00 AND BETWEEN S21 AND 23L. COMPLIED WITH REO 690-53-61-192-C AND EO R53137.Aug 1, 2011 · N932XJ · Cndair CL6002D24 · Fuselage Main, Plate/SkinSDR MALA110123Sign · brokenEMERGENCY EXIT SIGN ABOVE SERVICE DOOR BROKE LOOSE. INSTALLED NEW EXIT SIGN ASSY ABOVE SERVICE DOOR, PN BF5-0382-901.May 14, 2011 · N932XJ · Cndair CL6002D24 · Emergency LightingSDR MALA110088Light · malfunctionedNOTED GENERAL VICINITY, LT GALLEY ARE EMERGENCY FLOOR PATH LIGHTING DEGRADED. R & R LT GALLEY EMERGENCY FLOOR PATH LIGHTING. REF AM 3-51, OPS CHECKS GOOD.Apr 15, 2011 · N932XJ · Cndair CL6002D24 · Emergency LightingSDR MALA110062Glowstrip · detachedEMERGENCY FLOOR GLOW IN THE DARK STRIP HAS BECOME DETACHED IN FRONT OF GALLEY CART. RESECURED EMERGENCY FLOOR GLOW STRIP.Mar 20, 2011 · N932XJ · Cndair CL6002D24 · Emergency EquipmentSDR MALA110055Door Frame · gougedDOOR FRAME UPPER AFT GOUGED. REPAIRED AFT UPPER DOOR SEALS USING REO 670-53-22-001 TYPE 1 AS REF.Mar 8, 2011 · N932XJ · Cndair CL6002D24 · Fuselage Main, Structure
Back to N932XJ