N9619V
Service difficulty reports · 171
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N9619V' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N9619V' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA20131216004Cusp Web · corrodedCUSP WAS CORRODED AT STATION 378. INSTALLED REPAIR DOUBLER IAW AARD 53-20-00-16.SDR AALA20131212005Cargo Track · corrodedCORROSION ON LT HAND AFT CARGO TIE DOWN TRACK FROM STATIONS 1212 TO 1322. REPLACED TIE DOWN TRACK IAW AARD 51-00-05-1.SDR AALA20131209007Cargo Track · corrodedCORROSION ON RT HAND AFT CARGO TIE DOWN TRACK FROM STATIONS 1212 TO 1322. INSTALLED NEW TIE DOWN TRACK IAW AARD 51-00-05-1.SDR AALA20121021001Connector · disconnectedEMERGENCY ESCAPE PATH MARKING LIGHT ON SEAT 22D INOPERATIVE. RECONNECTED SEAT CONNECTOR. OPS CHECK NORMAL.SDR AALA20111229LGA02Battery Pack · dischargedCEILING EMERGENCY LIGHTS FROM ROWS 28 TO 30 INOPERATIVE. REPLACED BATTERY PACK AT ROW 28. OPS CHECK NORMAL.SDR AALA20111229LGA01Battery Pack · dischargedCEILING EMERGENCY LIGHTS FROM ROWS 7 TO 11 INOPERATIVE. REPLACED BATTERY PACK AT ROW 08. OPS CHECK NORMAL.SDR AALA20110930DWH01Skin · damagedDAMAGE FOUND AT FORWARD PASSENGER DOOR FUSELAGE SKIN DOOR HOLD OPEN CUTOUT. ACCOMPLISHED DOUBLER REPAIR EA MD80-019392 AND MD80 SRM 53-04-00 FIGURE 24 REF TO BOW FMR/002 S/N 1678214 DATED 9-23-11.SDR AALA20110819TUL01Augment Valve · inoperativeABQ - INFLIGHT PHX-DFW. CREW REPORTED WHILE IN CRUISE, SELECTED ENGINE ANTI ICE ON AND ELECTRICAL ODOR WAS NOTICED IN THE COCKPIT AND CABIN. ENGINE ANTI ICE WAS TURNED OFF AND THE ODOR DISSIPATED. SHORTLY THERE AFTER, COMPRESSOR STALLS WERE EXPERIENCED ON BSDR AALA20110502DFW02Shroud · brokenSEAT 12DEF EMERGENCY LIGHT SHROUD BROKEN. REPLACED SEAT 12DEF EMERGENCY LIGHT SHROUD. OPS CHECK NORMAL.SDR AALA20110307TUL04Frame · wornTEMP CONTROL VALVE WEARING INTO FRAME 1380. INSTALLED DOUBLER PER AARD 53-10-00-28.SDR AALA20091118LGA02Battery Pack · dischargedEMERGENCY LIGHT AT OVER WING INOPERATIVE. REPLACED BATTERY PACK.SDR AALA20090908TUL01Beam · corrodedAFT DOOR BEAM AT STATION 1155 TO 1212, STRINGER 28 RIGHT CORRODED. REPAIRED DOUBLER UNDER AARD 53-10-00-3.SDR AALA20090902TUL05Beam · corrodedAFT CARGO DOOR BEAM CORRODED. REPAIRED UNDER AARD 53-10-00-3.SDR AALA20090902TUL09Skin · corrodedCORROSION ON FUSELAGE SKIN AT LONGERON 28 RIGHT. REMOVED AND INSTALLED DOUBLER IAW SRM 53-04-00.SDR AALA20090902TUL12Seat Track · corrodedCORROSION ON SEAT TRACK NUMBER 6 STATION 792 BEYOND LIMITS. INSTALLED SPLICE UNDER SRM 51-30-01.SDR AALA20090902TUL10Skin · damagedAFT CARGO DOOR OPENING AFT SIDE HAS DAMAGE. INSTALLED EXTERNAL DOUBLER REPAIR UNDER AARD 53-30-00.SDR AALA20090902TUL07Fitting · damagedFUEL LEAKING FROM RIGHT BATH TUB FITTING BOTTOM OF CENTER TANK STATION 890. INSTALLED 2 EACH BATH TUB FITTINGS UNDER SRM 51-30-05.SDR AALA20090902TUL08Doubler · damagedSTATIC PORT MOUNT HOLES FOR DOUBLER ARE NOT SYMMETRICAL. INSTALLED DOUBLER.SDR AALA20090902TUL06Frame · crackedAFT ACCESSORY 1418 FRAME CRACKED AT LONGERON 2 LEFT TO 2 RIGHT. INSTALLED DOUBLER IAW 53-11-04.SDR AALA20090902TUL13Skin · dentedDENT ON FUSELAGE SKIN STATION 222. INSTALLED REPAIR UNDER SRM 53-04-02.SDR AALA20090902TUL19Frame · crackedCRACK IN FRAME 1418 AT LONGERON 2 RIGHT. REPAIR DOUBLER INSTALLED UNDER SRM 53-03-00.SDR AALA20090827TUL06Flap · damagedSMMR TUL 9457 - AN INTERIM REPAIR WAS MADE ON A STATIC DISCHARGE HOLE ON THE EXTENDED EDGE LIMIT OF THE LEFT INBOARD FLAP PER SMMR TUL9457. ATBT 15JAN/TUL AT NEXT HEAVY C CHECK MAKE PERMANENT REPAIR OF LEFT INBOARD FLAP. REMOVED AND REPLACED TRAILING EDGE UNSDR AALA20090827TUL05Angle · crackedMID CARGO DOOR, AFT LOWER STOP FITTING T-ANGLE CRACKED BETWEEN HI-LOKS. REPLACED FORMER.SDR AALA20090827TUL04Skin · damagedSTATIC DISCHARGE DAMAGE LOCATED 25 INCHES FROM INBOARD END AND 4.5 INCHES FROM TRAILING EDGE. INSTALLED PERMANENT REPAIR DOUBLER PER SRM 57-01-00 FIGURE 5.SDR AALA20090827TUL03Skin · damagedSTATIC DISCHARGE DAMAGE ON LOWER SKIN 14.5 INCHES FROM TRAILING EDGE. DAMAGE WAS REMOVED AND DOUBLER WAS INSTALLED PER SRM 57-01-00 FIG 5 SHEET 1.SDR AALA20090827TUL02Bracket · crackedAFT VAULT DOOR UPPER BAYONET LATCH BRACKET CRACKED. REMOVED AND REPLACED BAYONET LATCH BRACKET PER ESO80186.SDR AALA20090828TUL07Skin · damagedDENT ON FUSELAGE 20 INCHES AFT OF FORWARD LAVATORY SERVICE PANEL. INSTALLED INTERNAL DOUBLER REPAIR UNDER SRM 53-04-02.SDR AALA20090826TUL08Skin · dentedFORWARD ENTRY DOOR SKIN HAS IMPROPERLY INSTALLED RIVETS AND DEEP SKIN DENTS AT NUMBER 1 BEAM AFT END. REMOVED RIVETS, REWORKED SKIN, INSTALLED INTERNAL DOUBLER, AND REPLACED FASTENERS UNDER SRM 53-04-00 FIG 31.SDR AALA20090826TUL07Housing · gougedAFT SERVICE DOOR OUTER HANDLE PAN HAS DEEP GOUGE. REMOVED AND REPLACED HANDLE PAN (HOUSING) PER ESO 80175.SDR AALA20090826TUL01Angle · crackedMID CARGO DOOR FORWARD UPPER STOP FITTING T-ANGLE NEXT TO OUTER SKIN CRACKED IN RADIUS. REPLACED CRACKED T-ANGLE AT FORWARD UPPER STOP FITTING UNDER ESO 80174.SDR AALA20090828TUL09Pan · crackedCRACK IN WINDOW PAN AT STATION 1211 LONGERON 12 RIGHT. INSTALLED WINDOW PAN DOUBLER UNDER AARD 53-10-00-25.SDR AALA20090828TUL08Pan · crackedCRACK IN WINDOW PAN STATION 947 LONGERON 12 RIGHT. INSTALLED DOUBLER UNDER AARD 53-10-00-75.SDR AALA20090902TUL14Door Frame · corrodedMID CARGO DOOR BEAM CORRODED ON VERTICAL LEG. REMOVED CORROSION AND INSTALLED DOUBLER IAW AARD 53-10-00-3.SDR AALA20090825TUL32Pan · crackedWINDOW PAN IS CRACKED AT STATION 1098 RIGHT. REPAIRED UNDER AARD 53-10-00-25.SDR AALA20090825TUL31Pan · crackedWINDOW PAN IS CRACKED AT STATION 947 LEFT. REPAIRED UNDER AARD 53-10-00-25.SDR AALA20090825TUL30Pan · crackedWINDOW PAN IS CRACKED AT STATION 1021 LEFT. REPAIRED UNDER AARD 53-10-00-25.SDR AALA20090825TUL29Pan · crackedWINDOW PAN IS CRACKED AT STATION 1021 RIGHT. REPAIRED UNDER AARD 53-10-00-25.SDR AALA20090825TUL28Pan · crackedWINDOW PAN CRACKED AT STATION 1060 RIGHT. INSTALLED REPAIR DOUBLER UNDER AARD 53-10-00-25.SDR AALA20090825TUL27Pan · crackedWINDOW PAN CRACKED AT STATION 1022 LEFT. INSTALLED DOUBLER UNDER AARD 53-40-00-25.SDR AALA20090825TUL12Pan · crackedWINDOW PAN IS CRACKED AT STATION 1041. INSTALLED DOUBLER UNDER AARD 53-10-00-25.SDR AALA20090825TUL10Pan · crackedWINDOW PAN IS CRACKED AT STATION 1060. INSTALLED DOUBLER UNDER AARD 53-10-00-28.SDR AALA200802474AHose · leakingDFW INFLIGHT - RIGHT MAIN LANDING GEAR RED LIGHT ON WITH GEAR UP. RETURNED TO DFW AND LANDED WITHOUT INCIDENT. REPLACED HYDRAULIC FLEX LINE FOR RIGHT MAIN LANDING GEAR. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20070678Battery Pack · inoperativeTUL- EMERGENCY LIGHTS AT CABIN OVERWING EXITS INOPERATIVE. REPLACED BATTERY PACK AT STATION 875 FOR EMERGENCY LIGHTS AT CABIN OVERWING EXITS. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20060152Battery Pack · inoperativeLGA - FORWARD RIGHT HAND EMERGENCY EXIT DOOR SIGN INOPERATIVE. REPLACED BATTERY PACK FOR FORWARD RIGHT HAND EMERGENCY EXIT DOOR SIGN. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20050175Battery Pack · dischargedDFW - SEAT MOUNTED EMERGENCY LIGHTS FROM THE FRONT OF THE AIRCRAFT TO ROW 19 INOPERATIVE. REPLACED BATTERY PACK 2 EACH AND CHARGING MODULES 2 EA IN RIGHT HAND OVERHEAD BIN AT ROW 20 AND REPAIRED CHAFED WIRE IN RIGHT HAND SIDEWALL GRILL FOR SEAT MOUNTED EMERGESDR AALA20050076Oven · dirtyAUS - INFLIGHT CREW REPORTED SMOKE IN FIRST CLASS GALLEY. FOUND NUMBER ONE OVEN DIRTY AND SMOKING AROUND HEATER ELEMENT. STEAM CLEANED NUMBER ONE OVEN. RAN OVEN ONE HOUR AND CLEANED ELEMENTS AND INTERIOR OF OVEN. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20040474Contactor · defectiveDFW - EMERGENCY DIRECTIONAL LIGHT MOUNTED ON FORWARD GALLEY WALL INOPERATIVE. REPINNED QUICK DISCONNECT CONTACT FOR EMERGENCY LIGHT MOUNTED ON FORWARD GALLEY WALL. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20040444Battery Pack · inoperativeRDU - EMERGENCY EXIT LIGHTS IN FORWARD CABIN INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY LIGHTS IN FORWARD CABIN. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20040324Connector · looseDFW EMERGENCY ESCAPE PATH LIGHT MARKER AT FORWARD GALLEY WALL EXIT INOPERATIVE. RECONNECTED THE CONNECTOR FOR THE EMERGENCY ESCAPE PATH LIGHT AT THE FORWARD GALLEY WALL EXIT MARKER. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20040042Battery Pack · inoperativeCOCKPIT OVERHEAD EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACK AND CHARGER B5 23 FOR COCKPIT OVERHEAD EMERGENCY LIGHTS. SYSTEM GROUND CHECKED NORMAL OPERATION.
Back to N9619V