- Registered owner
- Umb Bank Na Trustee
- Location
- Salt Lake City, UT
- Owner type
- Corporation
- Serial number
- 11128
- Year built
- 2022
- Type
- Fixed wing multi engine
- Engine
- Turbo-fan
- Airworthiness
- Standard, transport
- Airworthiness date
- November 9, 2022
- Certificate issued
- November 9, 2022
- Expires
- November 30, 2029
- Mode S code
- AD775D
From the FAA registry file of October 24, 2026.
On this page
Airworthiness directives that may apply · 103
Matched by this aircraft’s airframe and engine models. Each AD’s applicability may narrow it by serial number, part number or equipment.
| 2017 | 3 |
|---|---|
| 2018 | 15 |
| 2019 | 17 |
| 2020 | 23 |
| 2021 | 15 |
| 2022 | 13 |
| 2023 | 16 |
| 2024 | 15 |
| 2025 | 20 |
| 2026 | 19 |
See all 156 ADs
Information bulletins that may apply · 2
Advisory, not mandatory.
Airframe · Airbus A320-271N
SAIB NE-19-03Escape Slide Maintenance Tasks and Intervals - JASC 2565Engine · IAE PW1127G-JM
SAIB 2026-11Theft of Turbofan Engine Parts before MutilationNTSB investigations
No NTSB investigations matched to N967NKMatched by N-number and event date, checked against the reported serial number, make and model. Investigations from before this aircraft carried the mark are under Earlier aircraft. Investigations on Airbus A320-271N aircraft
FAA incident reports
No FAA accident or incident reports matched to N967NKMatched by N-number and event date, checked against the reported make and model. Reports from before this aircraft carried the mark are under Earlier aircraft. Reports on Airbus A320-271N aircraft
Service difficulty reports · 13
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model.
SDR GTIA2026042739361Unknown · odorSTRONG SOCK SMELL ON TAKE OFF PACK 1 OFF ISOLATED SMELL-REF TSM 05-50-00-810-831-A C/W AMM 49-00-00-200-814-A NO DEFECT NOTED INSPECTING APU OR FUSELAGE. RAN PACKS IAW AMM 21-00-00 NO ODOR NOTED. LEVEL A DECONTAMINATION C/W.SDR GTIA2025090239056Skin · damagedPERMANENT REPAIR EXTERNAL SKIN LOCATED LOCATED BTW FR 69 TO FR 70 AT LEVEL STR 30R T O STR 33R RAF-01 3625188-02 GENERATED -PERFORMED PERMANENT REPAIR OF FUSELAGE SKIN AROUND THE AFT LAVATORY VENT OUTLET SKIN BTW FR.69 TO FR.70 AT LEVEL STR 31R TO STR 32R ATSDR GTIA2024122738627A/C Pack · odorFUME EVENT ON DESCENT ISOLATED TO PACK 2 -PERFORMED TSM 05-50-00 FOR CAUSE OF ODOR , APPLIED DECISION AND FOUND PACK 2 AS SOURCE OF ODOR , SEE LOG PAGE 3551645-1 FOR RT PACK MEL / DEACTIVATIONSDR GTIA2024121938608A/C Pack · odorFA REPORTS DIRTY SOCK SMELL AFT. NO SMELL REPORTED IN COCKPIT OR FWD SECTION OR CABIN-ACCOMPLISHED FAULT ISOLATION AS PER TSM 05-50-00-810-831-A . FOUND PACK 2 AS SOURCE SEE ITEM 2 FOR FINAL DISPOSITION MOC 119918SDR GTIA2024121638601A/C Pack · odorFA REPORT ROTTEN SHOWER SMELL DURING APPROACH-PERFORMED ENG RUN IAW AMM 71-00-00. FOUND PACK 2 TO BE THE SOURCE. REF LP 3551624-2 FOR MEL. MOC 114724SDR GTIA2024121638597Structure · contaminatedFUME EVENT REPORTED BY THE FLT ATTENDANTS ON FINAL APPROACH DIRTY SOCK SMELL-PERFROMED TSM 05-50-00-810-831 AND PERFOMRED TSM 71-00-00-810-847-A NO DEFECTS NOTED DURING TSM OF SYSTEM CLEANED VOMIT FROM BACK OF SEAT 26ASDR GTIA2024081638313Unknown · odorFUME EVENT DESCENDING THROUGH 10.000 FEET RAN FUMES CHECKLIST, COULD NOT IDENTIFY OR ISOLATE SOURCE-PERFORMED TSM 05-50-00-810-831A FOR ODOR EVENT. FOUND THE SOURCE TO BE COMING FROM #1 ENG & #1 PACKSDR GTIA2024081238304A/C Pack · odorFUME EVENT ON DESCENT THOUGH 7000' ISOLATED TO PACK 1-ACCOMP TSM 05-50-00-810-831-A. ISOLATED PACK 1 AS SOURCE. SEE ITEM 2 MOC 119918SDR GTIA2024080238270A/C Pack · odorON ARRIVAL WE STARTED GETTING A SLIGHT DIRTY SOCK SMELL AROUND 10000 AND ISOLATED PACK 1 AS CULPRIT-PERFORMED TSM # 05-50-00, RUN BOTH ENGINES, AND ISOLATE PACK 1+2, CONFIRMED PACK 1 TO BE THE SOURCE OF SMELL, PACK 2 OKSDR GTIA2024070238212A/C Pack · odorFUME EVENT DURING APPROACH PACK 1 TURNED OFF FUMES DISSIPATED. -PERFORMED TSM 05-50-00-810-831-A INSPECTED APU IAW AMM 49-00-00 AND ENG1 AND ENG2 IAW AMM 71-00-00 NO DEFECTS NOTED. LOCKED PACK 1 AS PRECAUTIONARY.SDR GTIA2024062038186A/C Pack · odorFUME EVENT DURING DESCENT DISSIPATED AFTER ELIMINATION OF ODOR / FUME FCOM PROCEDURE -REF TSM 05-50-00-810-831A FOUND SOURCE OF SMELL TO BE COMING FROM PACK #1 ALSO CONFIRMED BY FLIGHT CREW CAPT AND FO. REF L/P 3430441-2 FOR PACK #1 MEL RAN PACK #2 IAW AMM 12-SDR GTIA2024061438178Megaphone · inoperativeFORWARD MEGAPHONE INOP-R/R FWD MEGAPHONE IAW NKS DRAWINGS 25-60-00. OPS CHECK OK AT THIS TIMESDR GTIA2024021037893Unknown · odorFA'S REPORTED FUMES AND DIRTY SOX SMELL ON TOP OF DECENT AFTER WE LANDED WAITING FOR THE GATE. AIR QUALITY FORM SUBMITTED IN ACCORDANCE FOM.-PERFORMED INSPECTION OF AIR QUALITY EVENT IAW TSM 05-50-00-810-831-A. NO FAULTS NOTED. A/C OK FOR CONT'D SERVICE.
STCs that may be installed · 158
Approved for this aircraft’s airframe or engine model. The registry doesn’t record which STCs an aircraft has; its records do.
See all 158 STCs