N967SW

Service difficulty reports · 164

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N967SW' AND registry_match = 'registration'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR SWIA200617266Ecu · malfunctionedLEVELING AT 34,000 FLAPS DEPLOYED TO 5 DEG UNCOMMANDED FOR 5-6 SECONDS AND THEN RETRACTED TO 0, RETURNED TO DEN. REPLACED FECU IAW MM 27-41-05 AND REPLACED THE FLAPS HANDLE. FECU S/N 784. FLAP HANDLE P/N 7-45500-1, S/N 0524. OPERATIONAL CHECKS GOOD.Oct 10, 2006 · N967SW · Cndair CL6002B19 · Trailing Edge Flap Control SystemSDR SWIA200616480Smoke Detector · malfunctionedUPON TAXI TO THE GATE, RECVD CARGO SMOKE NR 1 CAUTION MSG LATCHED DURING TEST. REPLACED NR 1 FWD SMOKE DET IAW CRJ MM 26-15-01. OPERATIONAL CHECK GOOD.Mar 23, 2006 · N967SW · Cndair CL6002B19 · Smoke DetectionSDR SWIA200616440Actuator · malfunctionedFLAP FAIL CAUTION ON APP. REPLACED RT NR 1: NR 2; NR 3; NR 4 ACTUATORS IAW CRJ MM 27-53-05. OPERATIONAL CHECK GOOD, PN1 852D100-21; SN 1 OFF 5744 PN2 852D100-19; SN 2 OFF 5743 PN3 853D100-20; SN 3 OFF 3163, PN4 854D100-20; SN 4 OFF 2940.Mar 15, 2006 · N967SW · Cndair CL6002B19 · Trailing Edge Flap ActuatorSDR SWIA200616408Actuator · lack of lubeFLAPS FAILED IN 0 POSITION ON GROUND. LUBED ACTUATORS IAW AMM 12-20-27.Mar 9, 2006 · N967SW · Cndair CL6002B19 · Trailing Edge Flap ActuatorSDR SWIA200616117Actuator · malfunctionedNR 1 YAW DAMPER FAILS IN FLIGHT, YD1 INOP STATIS MESSAGE. REPLACED NR 1 YD ACTUATOR IAW PER CRJ MM 22-22-01. OPERATIONAL CHECK GOOD.Jan 12, 2006 · N967SW · Cndair CL6002B19 · Autopilot SystemSDR SWIA200516021Fcu · malfunctionedFLAP FAIL CAUTION MESSAGE ON LANDING. REPLACED FECU PER CRJ 200 MM 27-51-05. OPERATIONAL CHECK GOOD.Dec 15, 2005 · N967SW · Cndair CL6002B19 · Trailing Edge Flap Control SystemSDR SWIA200515825Floorbeam · crackedFOUND FLOOR SUPPORT ANGLE AT FS 621.00 LEFT IS CRACKED, ITEM FOUND AT C CHECK INSPECTION. REPAIR CRACKED SUPPORT ANGLE IAW CRJ REO 601R-53-61-117 REV "B".Jun 12, 2005 · N967SW · Cndair CL6002B19 · Fuselage Main, Floor BeamSDR SWIA200515824Floorbeam · crackedFOUND FLOORBEAM ANGLE AT FS 621.00 RT IS CRACKED, ITEM FOUND AT C CHECK INSPECTION. REPAIRED CRACKED FLOOR SUPPORT ANGLE IAW CRJ REO 601R-53-61-117 REV "B".Jun 12, 2005 · N967SW · Cndair CL6002B19 · Fuselage Main, Floor BeamSDR SWIA200515823Floorbeam · crackedFOUND FS 280 AT RBL 9 O/B FLOORBEAM ATTACH ANGLE IS CRACKED, ITEM FOUND AT C CHECK INSPECTION. REPLACED ANGLE IAW CRJ SRM 51-40-11, 51-42-06, 51-42-21, 51-23-00, 51-21-11, 51-25-01.Jun 12, 2005 · N967SW · Cndair CL6002B19 · Fuselage Main, Floor BeamSDR SWIA200414326Control Panel · faultyAILERON TRIM STICKS. REMOVED AND REPLACED AILERON/RUDDER TRIM CONTROL PANEL WITH A SERVICEABLE UNIT. OPERATIONAL CHECK GOOD.Dec 31, 2004 · N967SW · Cndair CL6002B19 · Aileron Tab Control SystemSDR SWIA200413718Pump · obstructedSITTING ON GROUND, FUEL TRANSFERS FROM MAIN TANKS TO CENTER TANK. REMOVED OBSTRUCTION IN RIGHT TRANSFER EJECTOR PUMP. OPERATIONAL CHECK GOOD IAW 28-13-01.Aug 18, 2004 · N967SW · Cndair CL6002B19 · Aircraft Fuel Distribution SystemSDR SWIA200413443Switch · stuckSTAB TRIM 1 AND 2 AND MACH TRIM FAILED ON TAKEOFF. RETURNED TO FIELD, FOUND CO-PILOT TRIM DISCONNECT SWITCH JAMMED. RESET, OPS CHECKS GOOD.Jun 13, 2004 · N967SW · Cndair CL6002B19 · Stabilizer Control SystemSDR SWIA200413089Control Lever · malfunctionedWHEN LANDING GEAR SELECTED DOWN, GEAR WOULD NOT LOWER. HANDLE HAD LESS RESISTANCE THAN NORMAL. FOLLOWED GEAR DOWN DISAGREE PROCEDURE TO LOWER MANUALLY. HYDRAULICS INDICATED NORMAL PRESSURE. PERFORMED EMERGENCY LANDING AT SFO. UPON LANDING, LOST NOSE WHEELMar 26, 2004 · N967SW · Cndair CL6002B19 · Landing Gear SelectorSDR SWIA200312631Actuator · malfunctionedSTAB TRIM CH 2 WILL NOT TEST. TRIM WILL KICK OFF WHEN ATTEMPTING TO RUN THE TRIM WITH JUST STAB TRIM CH 2 AND MACH TRIM ENGAGED. REMOVED AND REPLACED THE HORIZONTAL STABILIZER ACTUATOR AND HORIZONTAL STABILIZER MOTOR CONTROL UNIT IAW MM 27-42-05. OPS CHECK Nov 25, 2003 · N967SW · Cndair CL6002B19 · Stabilizer Control System
Back to N967SW