N979RP

Service difficulty reports · 126

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N979RP' AND registry_match = 'registration'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR UHLA2011031100113Battery · faultedEMERGENCY LT BATT FAULT IN FLIGHT. MAINTENANCE PERFORMED OPS CHECK OF SYSTEM IAW EMB 170 MM 33-51-00. THE A/C WAS ROUTED TO A HANGAR THAT NIGHT FOR TROUBLESHOOTING. MAINTENANCE REPLACED GS0266 AND C/P P0546 IAW EMB 170 SWPM 20-41-20 AND 20-50-10.Mar 11, 2011 · N979RP · Emb ERJ170100SE · Emergency LightingSDR UHLA2011020900077Warning System · activatedEMERG LT BATT FAULT CAS MESSAGE. PERFORMED OPS CHECK IAW EMB 170 MM 33-50-00.Feb 9, 2011 · N979RP · Emb ERJ170100SE · Emergency LightingSDR UHLA2011020900076Light · malfunctionedEMERGENCY LIGHTS FLASHING ON AND OFF IN FLIGHT. PERFORMED OPS CHECK GOOD IAW EMB 170 MM 33-50-00-5. COULD NOT DUPLICATE, OPS CHECK GOOD.Feb 9, 2011 · N979RP · Emb ERJ170100SE · Emergency LightingSDR UHLA2011020900075Battery Pack · dischargedEMERGENCY LT BATTERY FAULT EICAS MESSAGE. REMOVED AND REPLACED AFT RIGHT OUTBD BATTERY PACK IAW EMB MM 33-50-01.Feb 9, 2011 · N979RP · Emb ERJ170100SE · Emergency LightingSDR UHLA2011020800073Battery Pack · dischargedEMER BATTERY FAULT. REMOVED AND REPLACED SERVICEABLE L2 DOOR POSITION 4 AND 6 OVERHEAD EMERGENCY BATTERY PACK IAW MM 33-50-09-04. OPS CHECK OK.Feb 8, 2011 · N979RP · Emb ERJ170100SE · Emergency LightingSDR UHLA2011020600065Circuit Card · defectiveEMER LT BATT FAULT EICAS MESSAGE. RESET AFT CENTER EMERGENCY BATTERY PACK FOR EXIT LIGHT IAW EMB 170 MM 33-50-01. OPS CHECK GOOD. MAINTENANCE LATER REMOVED AND REPLACED MAU NR 3 GEN I/O SLOT 9/10 AND SPDA NR 2 DISCRETE I/O SLOT 9 AFTER TROUBLESHOOTING. OPSFeb 6, 2011 · N979RP · Emb ERJ170100SE · Emergency LightingSDR UHLA2011020500064Power Supply · inoperativeEMER LT BATT FAULT ON EICAS. REMOVED AND REPLACED NR 4 EMER LT POWER SUPPLY, OPS CHECK GOOD IAW EMB 170 MM 33-51-01.Feb 5, 2011 · N979RP · Emb ERJ170100SE · Emergency LightingSDR UHLA2011020500063Light · malfunctioned"EMER LT BATT FAULT" ON EICAS. OVERHEAD CABIN EMERGENCY LIGHTS 3 AND 5 REMAIN ILLUMINATED WITH EMERGENCY LIGHTS IN ARMED POSITION. PERFORMED OPS CHECK OF EMER LIGHTS IAW EMB MM 33-50-01. OPS CHECK GOOD.Feb 5, 2011 · N979RP · Emb ERJ170100SE · Emergency LightingSDR UHLA2011020400059Battery · dischargedEMERGENCY LT BATTERY FAULT AND TWO EMERGENCY LIGHTS IN AFT CABIN ON. REMOVED AND REPLACED AFT RT O/B EMERGENCY LIGHT BATTERY IAW EMB 170 MM 33-50-01. OPS CHECK GOOD.Feb 4, 2011 · N979RP · Emb ERJ170100SE · Emergency LightingSDR UHLA2011020300058Battery · malfunctionedEMERGENCY LT BATTERY FAULT. RESET AFT BATTERY, OPS CHECK GOOD.Feb 3, 2011 · N979RP · Emb ERJ170100SE · Emergency LightingSDR UHLA2011013100056Battery · dischargedEMER LT BATT FAULT CYAN MESSAGE ON EICAS. REMOVED AND REPLACED AFT OUTBD EMERGENCY LIGHT BATTERY IAW EMB 170 MM 33-50-01.Jan 31, 2011 · N979RP · Emb ERJ170100SE · Emergency LightingSDR UHLA2011013000055Power Unit · inoperativeEMER LT BATT FAULT. REMOVED AND REPLACED RHOB EMERGENCY LIGHT POWER UNIT IAW EMB 170 MM 33-50-01. OPS CHECK GOOD.Jan 30, 2011 · N979RP · Emb ERJ170100SE · Emergency LightingSDR UHLA2010121600325Door · bindsCREW REPORTED L1 DOOR HARD TO CLOSE. ON CALL MAINTENANCE CLOSED DOOR, NO DEFECTS NOTED.Dec 16, 2010 · N979RP · Emb ERJ170100SE · Passenger/Crew DoorsSDR UHLA2010112300234Processor · malfunctionedON ARRIVAL INTO ORD, RECEIVED AVNS MAU 3A FAIL EICAS MESSAGE ALONG WITH ASSOCIATED MESSAGES. RAN QRH AND DECLARED AN EMERGENCY. LANDED WITHOUT INCIDENT. MAINTENANCE REMOVED AND REPLACED THE NIC PROC 5 AND MAU 3 POWER SUPPLY 1.Nov 23, 2010 · N979RP · Emb ERJ170100SE · Central ComputersSDR UHLA2010090300151Epsu · inoperativeEMERGENCY LIGHT OVER ROW 2 INOP. REPLACED EMERGENCY LIGHT OVER ROW 2 IAW EMB 170 MM 33-50-13 AND EMERGENCY POWER LIGHT UNIT NR 2 IAW EMB 170 MM 33-50-01. OPS CHECK GOOD.Sep 3, 2010 · N979RP · Emb ERJ170100SE · Emergency LightingSDR UHLA2010042800044Gusset · corrodedLEVEL 2 CORROSION AFT GALLEY AT FRM 85 FLOORBEAM. REMOVED AND REPLACED GUSSET PLATES IAW EMB 170 SRM 51-41-02 AND 51-23-06.Apr 28, 2010 · N979RP · Emb ERJ170100SE · Fuselage Miscellaneous StructureSDR UHLA2010042800043Seat Track · corrodedLEVEL 2 CORROSION IN FWD GALLEY RT SEAT TRACK BEAM. REMOVED BEAM AND MATCH DRILLED NEW BEAM IAW EMB 170 SRM 51-41-01. COMPLETE INSTALL OF RT SEAT TRACK BEAM IAW EMB 170 SRM 51-41-02, 51-41-01, 51-43-01, AND 51-43-02.Apr 28, 2010 · N979RP · Emb ERJ170100SE · Fuselage, Seat/Cargo Attach FittingsSDR UHLA2009100500066Splice · damagedEMERGENCY LIGHTS CAME ON IN FLIGHT. LIGHTS EXTINGUISHED. MAINTENANCE LATER REPLACED SPLICE SP3874 AND GROUND STUD GS0266DC. THERE HAVE BEEN NO WRITE UPS SINCE.Oct 5, 2009 · N979RP · Emb ERJ170100SE · Light System WiringSDR UHLA2009092700065Module · inoperativeEMER LIGHTS OVER R2 DOOR AREA STUCK ON. RESET BATTERY PACK. ON 9/30/09 MX UPGRADED ALL ELPU'S IAW SE335001 AND REPLACED SPDA 2 SLOT 9 DISCRETE I/O.Sep 27, 2009 · N979RP · Emb ERJ170100SE · Emergency LightingSDR UHLA2009092300061Power Supply · inoperativeEMERGENCY LIGHT OVER R2 ILLUMINATED IN FLIGHT. MAINTENANCE REPLACED THE LT AFT EMERGENCY LIGHT POWER SUPPLY. OPS CHECK GOOD IAW EMB 170 MM 33-50-00.Sep 23, 2009 · N979RP · Emb ERJ170100SE · Emergency LightingSDR UHLA2009092000060Battery · dischargedEMERGENCY LIGHT OVER R2 DOOR STUCK ON. MAINTENANCE RESET. THE EMERGENCY BATTERY WAS LATER REPLACED.Sep 20, 2009 · N979RP · Emb ERJ170100SE · Emergency LightingSDR UHLA2009091400059Warning System · malfunctionedEMER LT BATT FAULT ON TAXI OUT. MAINTENANCE RESET POWER AND OPS CHECKED GOOD.Sep 14, 2009 · N979RP · Emb ERJ170100SE · Emergency LightingSDR UHLA2009072800053Light · malfunctionedEMERGENCY LIGHTS CAME ON IN FLIGHT, OVER ROW 8 AND 11 WITHOUT BEING COMMANDED ON. EMERGENCY LIGHTS IN AFT ALSO CAME ON. MX CYCLED ACFT PWR AND TESTED EMERGENCY LIGHTS IAW MM 33-50-01. SYS OPERATES NORMALLY.Jul 28, 2009 · N979RP · Emb ERJ170100SE · Emergency LightingSDR UHLA2009062300044Wire Harness · damagedON DESCENT, MOVED FLAPS TO 5 AND RECEIVED CREW AWARENESS OF FLAPS POSITION 5 AND SLATS FULL. THEN RECEIVED SLAT FAIL AND TRIED TO BRING FLAPS/SLATS BACK TO 0 FLAPS RETRACTED AND SLATS FROZE AT FULL EXTENSION. NO EMERGENCY DECLARED. MAINTENANCE CLEARED SF-ACEJun 23, 2009 · N979RP · Emb ERJ170100SE · Flight Control System WiringSDR UHLA2009020900021Uplock · inoperativeON APPROACH DURING NORMAL GEAR EXTENSION, THE LEFT MAIN GEAR DID NOT EXTEND. RECEIVED THE MASTER WARNING FOR LG DISAGREEMENT. PROCEEDED WITH A GO-AROUND AND RAN THE QRH. PER THE QRH, ACHIEVED DOWN, LOCKED AND THREE GREEN WITH A NORMAL EXTENSION. RETURNED TFeb 9, 2009 · N979RP · Emb ERJ170100SE · Landing Gear Retraction/Extension SystemSDR 20051181Flap System · unknownWHILE ON DECENT, THE CREW RECEIVED A NO FLAP/FLAP LO RATE WARNING. THE CREW MADE AN EMERGENCY DECENT AND LANDED WITHOUT INCIDENT.Nov 7, 2005 · N979RP · Emb ERJ170100 · Trailing Edge Flap Control System
Back to N979RP