N105WP, cancelled May 16, 2006
Service difficulty reports · 90
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N105WP' AND deregistration_id = 'N105WP-2006-05-16' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N105WP' AND deregistration_id = 'N105WP-2006-05-16' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR RRXA10694Nut Plate · damagedDURING MAINTENANCE VSIT FOUND LT WING L/E FUEL TANK ATTACH SCREW TO LONG DAMAGE TO NUT PLATE AT XW-0 TO XW200 (EO), DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA10720Seat Track · damagedDURING A MAINTENANCE VISIT FOUND BROKEN LOBE DAMAGE TO SEAT TRACK AT STA 120 AND X+23, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA10719Seat Track · damagedDURING A MAINTENANCE VISIT FOUND BROKEN LOBE DAMAGE TO SEAT TRACKS AT STA 640 AND X+47, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA10723Seat Track · wornDURING A MAINTENANCE VISIT FOUND WORN DAMAGE TO SEAT TRACK AT STA 1120 - 1140 AND X+47.5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA10722Skin · dentedDURING A MAINTENANCE VISIT FOUND DENT DAMAGE TO RT AILERON AT O/B CONTROL TAB, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA10721Stiffener · crackedDURING A MAINTENANCE VISIT FOUND CRACKED DAMAGE TO W/W VERT STIFFENER AT STA 940 AND WING ROOT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA10718Floorbeam · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO MAIN CARGO COMP FLOOR BEAM AT STA 200 LT OF L22, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA10717Seat Track · wornDURING A MAINTENANCE VISIT FOUND WORN DAMAGE TO SEAT TRACK AT STA 767 - 780 AND X+23, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA10716Seat Track · wornDURING A MAINTENANCE VISIT FOUND WORN DAMAGE TO SEAT TRACK AT STA 767 - 780 AND X+47, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA10715Seat Track · wornDURING A MAINTENANCE VISIT FOUND WORN DAMAGE TO SEAT TRACK AT STA 520 - 540 AND X+47, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA10714Seat Track · wornDURING A MAINTENANCE VISIT FOUND WORN DAMAGE TO SEAT TRACK AT STA 1120 - 1140 AND X+23, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA10713Seat Track · wornDURING A MAINTENANCE VISIT FOUND WORN DAMAGE TO SEAT TRACK AT STA 1030 - 1050 AND X+23, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA10712Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLE DAMAGE TO SEAT TRACK LOCK HOLE AT F/E RIGHT SEAT DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA10711Seat Track · wornDURING A MAINTENANCE VISIT FOUND WORN DAMAGE TO SEAT TRACK AT F/E''S LT SIDE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA10708Seat Track · wornDURING A MAINTENANCE VISIT FOUND WORN DAMAGE TO SEAT TRACK AT STA 970 - 978 AND X+23, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA10707Seat Track · wornDURING A MAINTENANCE VISIT FOUND WORN DAMAGE TO SEAT TRACKS AT STA 930 - 980 AND X+47.5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA10706Seat Track · wornDURING A MAINTENANCE VISIT FOUND WORN DAMAGE TO SEAT TRACK AT STA 1540 - 1560 AND X=0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA10705Seat Track · wornDURING A MAINTENANCE VISIT FOUND WORN DAMAGE TO SEAT TRACK AT STA 1402 - 1412 AND X-47, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA10704Seat Track · wornDURING A MAINTENANCE VISIT FOUND WORN DAMAGE TO SEAT TRACK AT STA 1390 AND X-47, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA10703Skin · chafedDURING A MAINTENANCE VISIT FOUND 8 INCHES WEAR/RUBB SPOT DAMAGE TO LT ELEVATOR AT MID SECTION, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA10702Doubler · crackedDURING A MAINTENANCE VISIT FOUND CRACK BEYOND STOP DRILL DAMAGE TO B-PIT DOOR AT BOTTOM FWD DOUBLER, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA10701Seat Track · wornDURING A MAINTENANCE VISIT FOUND WORN DAMAGE TO SEAT TRACK AT STA 1125 - 1135 AND X-47, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA10700Seat Track · wornDURING A MAINTENANCE VISIT FOUND WORN DAMAGE TO SEAT TRACK AT STA 1568 - 1620 AND X+47, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM.SDR RRXA10699Seat Track · wornDURING A MAINTENANCE VISIT FOUND WORN DAMAGE TO SEAT TRACK AT STA 1542 - 1546 AND X+22.5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA10698Seat Track · wornDURING A MAINTENANCE VISIT FOUND WORN DAMAGE TO SEAT TRACK AT STA 1123 - 1131 AND X-22.5, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM.SDR RRXA10697Seat Track · wornDURING A MAINTENANCE VISIT FOUND WORN DAMAGE TO SEAT TRACK AT STA 1125 - 1135 AND X-0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA10696Seat Track · wornDURING A MAINTENANCE VISIT FOUND WORN DAMAGE TO SEAT RAIL AT STA 972-979 AND X-47.5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA10695Seat Track · wornDURING A MAINTENANCE VISIT FOUND WORN DAMAGE TO SEAT TRACK AT STA 952-957 AND X-57, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA10710Seat Track · wornDURING A MAINTENANCE VISIT FOUND WORN DAMAGE TO SEAT TRACK AT STA 765 - 779 AND X=0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA10709Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO MAIN CARGO COMP FLOOR PANEL AT STA 505 - 506 AND X-1.5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA991479Depressor · bentDURING A MAINTENANCE VISIT, FOUND AFT LOWER MAIN CARGO DOOR SEAL DEPRESSOR BENT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. RETURNED TO ORIGINAL CONTOUR AND WELDED IAW COTNEY DRAWING NR J40-R01 WITH APPROVED 8110-SDR RRXA99662Pressurization · malfunctionedUNABLE TO PRESSURIZE AIRCRAFT. AIRCRAFT FERRIED TO BIRMINGHAM FOR DOOR MAINTENANCE.SDR RRXA991071Spar · misdrilledDURING A MAINTENANCE VISIT FOUND DOUBLE DRILLED, WING, FWD LWR SPAR CAP AT PYLON NR 1, STA XW 467.0, ONE EACH HOLE DOUBLE DRILLED IN SPAR, INTERNAL DOUBLER, AND LOWER WING SKIN IN TEE DOUBLER OUT OF ROUND, PAST 3RD OVERSIZE. DAMAGE EXCEEDED LIMITS IAW DC-8 SRSDR RRXA991080Fitting · damagedDURING A MAINTENANCE VISIT FOUND AN OVERSIZED HOLE, RUDDER SPAR FITTING AT STA ZR=61.156. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR BUSHING IAW FAA APPROVED TIMCO DER ENGINEERING SSDR RRXA991079Bore · oversizedDURING A MAINTENANCE VISIT FOUND BORE OVERSIZED, MAIN LANDING GEAR LINK BORE, AND HAS ONE LOCATION OF LOCAL BLENDING. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR BUSHINGS IAW FAA APSDR RRXA991066Mount · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS OVERSIZED HOLES, NR 4 PYLON MOUNT AREA. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLERS IAW FAA APPROVED TIMCO DER ENGINEERING SKETCH SDR RRXA991078Jamb · misdrilledDURING A MAINTENANCE VISIT FOUND DOUBLE DRILLED IN VARIOUS LOCATIONS, L-2 ENTRY DOOR AFT JAMB AT STA 1666 AND STA 1660. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLERS IAW FAA SDR RRXA991077Floorbeam · gougedDURING A MAINTENANCE VISIT FOUND GOUGE, FLOORBEAM, FUSELAGE, AT STA 52, UPPER AFT FLANGE HAS DEEP TOOL GOUGE AT BL 36 LEFT ON UNDERSIDE OF FLANGE. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. REPAIRED IAW FAA APPROSDR RRXA991076Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED, FLOORBEAM, AT STA 660, UPPER FLANGES. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. REPAIRED IAW FAA APPROVED TIMCO DER ENGINEERING SKETCH NR REO-06273 AND DC08-53-0351, SDR RRXA991075Door Pan · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED, AFT SERVICE DOOR, AFT LWR DOOR PAN, IN TWO PLACES. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR ANGLE, FILLER, AND DOUBLERS IAW FAA APPROSDR RRXA991074Frame · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLE, FUSELAGE, FRAME AT STA 1140, LONGERON 35 LEFT AT AN INTERCOSTAL LOCATION. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW SDR RRXA991073Floorbeam · damagedDURING A MAINTENANCE VISIT FOUND DAMAGE, FUSELAGE, FLOORBEAM AT STA 1140, BL 0.0, NO SRM. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR SHIM, ANGLE, AND DOUBLER IAW FAA APPROVED TIMCOSDR RRXA991072Floorbeam · misrepairedDURING A MAINTENANCE VISIT FOUND TWO CUTOUTS, FUSELAGE, FLOORBEAM, UPPER FORWARD FLANGE, AT STA 680. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLERS IAW FAA APPROVED TIMCO DER ENGINESDR RRXA991061Fitting · misdrilledDURING A MAINTENANCE VISIT FOUND OVERSIZED HOLE, RUDDER SPAR FITTING AT STA ZR 61.156 HAS OVERSIZED ATTACH HOLE. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW OVERSIZED BUSHING IAW FAA ASDR RRXA991063Floorbeam · crackedDURING A MAINTENANCE VISIT FOUND CRACKS, FUSELAGE, FLOORBEAM AT STA 160 AND STA 180, BL 40 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED STRAPS, ANGLES, AND DOUBLERS IAW FAA APPROVED TSDR RRXA991062Floorbeam · crackedDURING A MAINTENANCE VISIT FOUND CRACKS, FUSELAGE, FLOORBEAM, AT STA 160 AND STA 180, CRACKED AT APPROX BL 40 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED STRAPS, ANGLES, AND DOUBLERSSDR RRXA991070Floorbeam · damagedDURING A MAINTENANCE VISIT FOUND A TRIM OUT, FUSELAGE, LONGITUDINAL FLOORBEAM AT BL 11.5 RIGHT FROM STA 21 TO STA 25 IN THE UPPER HORIZONTAL FLANGE AND A BLEND OUT IN THE VERTICAL FLANGE. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAWSDR RRXA991069Fitting · mismanufacturedDURING A MAINTENANCE VISIT FOUND MATERIAL SUBSTITUTION, P/N: 3616112-3 FITTING IS MADE FROM P/N: 3616111 7075-T6 FORGING. REQUEST TO FAB FROM ALUMINUM BAR. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED ASDR RRXA991160Longeron · crackedDURING A MAINTENANCE VISIT FOUND A CRACK AND CORROSION, FUSELAGE, LONGERON 36 BETWEEN STA 260 AND STA 300. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR SECTION OF LONGERON IAW DAC DWSDR RRXA991068Fitting · crackedDURING A MAINTENANCE VISIT FOUND CRACKED SPLICE FITTING AT STA 510, LONGERON 36. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPLACEMENT SPLICE IAW FAA APPROVED TIMCO DER ENGINEERING SKETCH
Back to N105WP, cancelled May 16, 2006