What was found
DURING A MAINTENANCE VISIT FOUND DOUBLE DRILLED IN VARIOUS LOCATIONS, L-2 ENTRY DOOR AFT JAMB AT STA 1666 AND STA 1660. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLERS IAW FAA APPROVED TIMCO DER ENGINEERING SKETCH NR REO- 06279