N124CJ, cancelled Aug 27, 2013
Service difficulty reports · 20
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N124CJ' AND deregistration_id = 'N124CJ-2013-08-27' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N124CJ' AND deregistration_id = 'N124CJ-2013-08-27' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR NSVA20070181Handle · lack of lubeJUST AFTER BRAKE RELEASE, CARGO DOOR LIGHT ILLUMINATED. LUBED DOOR HANDLE, OP CHECKS GOOD.SDR NSVA20070129Fire Loop · defectiveT-HANDLE AND FIRE EXTINGUISHER DISCHARGE LIGHTS DO NOT ILLUMINATE DURING TEST. REMOVED AND REPLACED LT ENG AFT FIRE LOOP, OPS CK GOOD IAW 26-10-01 P/N 244-09015 S/N 034119.
SDR NSVA20070115Fire Loop · out of positionLT FIRE LOOP WILL NOT TEST. REMOVED AND REPLACED LT ENGINE FIRE LOOP HARNESS FROM FWD FIRE SEAL TO AFT FIRE WALL REF. BEECH 1900D MM 26-10-01. OPS CHECK GOOD, PN ON/OFF 70522.SDR NSVA20070104Circuit Board · malfunctionedRIGHT TEST B FIRE LOOP INOP. REPLACED PCB P/N 101-364580-1 S/N OFF 672C93 S/N ON 579-M92, REPLACED PCB P/N 129-364079-7 S/N OFF 898J94 S/N ON 743-H-93, ANNUNCIATOR POWER LIGHT AND LT OIL PRESS WARNING LOW, OPS CHECK GOOD IAW MM 31-10-00.SDR NSVA20070083Control Cable · out of adjustRT COND LEVER FAILS TO REACH HIGH IDLE POSITION INSPECTED CABLE AT FUEL CONTROL NO BINDING NOTED PERFORMED GROUND RUN OPS CHK VERIFIED NR 2 ENG MAKES LOW IDLE AND FUEL CUTOFF FUNCTIONS NORMAL. ADJUSTED ROD END ON RT CONDITION CABLE AT FCU. RESAFTIED ROD END SDR NSVA20070051Connector · corrodedLANDING GEAR WOULD NOT RETRACT AFTER TAKEOFF. CLEARED CORROSION FROM A10881 CONNECTOR, PINS 5/9 P NR ZONE 521, OPS CK GOOD IAW 32-60-05.SDR NSVA20070024Fire Loop · malfunctionedWHEN TESTING THE LT FIRE LOOP THE LEFT T HANDLE ILLUMINATED AND THE ANN DID NOT ILLUMINATE. REPOSITIONED LT FIRE LOOP NEAR LT EXHAUST STACK, INSPECTED FWD DIRE SEAL CONNECTIONS AND AFT GROUND, NDN, INSPECTED CONNECTIONS AT AMP NG AND PERFORMED ALL OPS CHECKS,SDR NSVA200600184Governor · malfunctionedLEFT TORQUE INDICATOR INNACURATE WHEN CHANGING POWER. REMOVED AND REPLACED LEFT PROP GOV PN 8210-410 IAW 61-20-02, OPS CHECK GOOD.SDR NSVA200600114Bracket · crackedLANDING GEAR HANDLE LIGHT ILLUMINATED DURING LANDING ROLLOUT WITH HORN AND NOSE GEAR ANNUNCIATOR EXTINGUISHED. FOUND DOWNLOCK SWITCH BRACKET CRACKED. REMOVED AND REPLACED DOWNLOCK SWITCH BRACKET RIGGED, OPS CHECK NORMAL.SDR NSVA200600108Door · inoperativeLT EMERGENCY EXIT WOULD NOT OPEN FROM INSIDE OF A/C. REPLACED SHAFT COUPLING, CAM AND BEARING ON LT EMER. EXIT LATCH MECHANISM IAW 52-20-01 SHAFT PN 129-514033-1, CAM PN 129-514065-1, COUPLING PN 129-514067-1, BEARINGS PN FF718-1, SPRING PN MS9048-170.SDR 01302006AGauge · sticksRT TORQUE GAUGE STICKS ON GROUND AND INFLIGHT. RT TORQUE GAUGE PN ON/OFF 129-380004-3, SN ON 304, SN OFF 368. OPS CHECK GOOD IAW 31-10-00.SDR 10212005AFire Detector · malfunctionedRT FIRE LOOP ANNUNCIATOR ILLUMINATED DURING RUNUP AND REMAINS ON. INSPECTED FIRE LOOPS, CANNON PLUGS AND A319 NO DEFECTS NOTED. REMOVED AND REPLACED FIRE DETECTION CONTROL UNIT. OPS CHECK GOOD, PN 477-90005, SN 9036-005.SDR 10172005AFire Detector · malfunctionedRT FIRE LOOP STUCK IN TEST MODE. INSPECTED FIRE LOOP NO DEFECTS FOUND, INSPECTED CONTROLLER AND C/B, NO DEFECTS NOTED, DISCONNECTED LOOP AT FIREWALL, FIRE LOOP LIGHT REMAINED ON, RECONNECTED LOOP AT FIREWALL LIGHT REMAINED ON. FOUND FIRE DETECTION CONTROL BOSDR 09092005CFire Loop · failedLT FORWARD FIRE LOOP TEST FAIL. REMOVED AND REPLACED LEFT FORWARD FIRE LOOP. OPS CHECK GOOD.SDR 08082005BElevator · damagedRT ELEVATOR, OUTBOARD HINGE POINT HAS THREE LOOSE RIVETS.SDR 08082005AElevator · damagedLT ELEVATOR, THREE RIVETS NEED REPLACED ON OUTBOARD ELEVATOR ATTACH POINT.SDR 08042005CWire · brokenNO DOWNLOCK INDICATION WHEN GEAR DOWN. REPAIRED BROKEN WIRE.SDR 06092005AGovernor · malfunctionedNOTICED RIGHT YAW WHEN POWER REDUCED DURING LANDING FLARE. REMOVED AND REPLACED PROP GOVERNOR.SDR 341024Engine · failedRIGHT ENGINE FAILURE INFLIGHT.SDR 097041Fire Detector · damagedIN CRUISE RT FIRE HANDLE ILLUMINATED FOR 4 SECONDS AND WENT OUT. REMOVED AND REPLACED RT ENGINE FIRE DETECTION CABLE IAW 26-10-01 OPS CHECKED GOOD