SDR SCNA96276Floorbeam · crackedDURING HEAVY MAINTENANCE, FOUND FLOORBEAM CRACKED AT BS 735 IN THE LOWER GALLEY AREA. CUT OUT MATERIAL, FABRICATED AND INSTALLED A REPAIR IN ACCORDANCE WITH SRM 53-00-01 AND 53-13-01.Sep 21, 1996 · N151SY · Doug DC1015 · Fuselage Main, Floor BeamSDR SCNA96308Intercostal · corrodedDURING HEAVY MAINTENANCE, FOUND CORROSION AROUND NUTPLATE UNDER SEAT TRACK AT BS 1841, RBL 27. REMOVED INTERCOSTAL, FABRICATED AND INSTALLED A NEW INTERCOSTAL IN ACCORDANCE WITH SRM 53-30-01.Sep 20, 1996 · N151SY · Doug DC1015 · Fuselage Miscellaneous StructureSDR SCNA96300Floorbeam · corrodedDURING HEAVY MAINTENANCE, FOUND CORROSION ON THE FLOORBEAM BELOW THE THRESHOLD ON THE FORWARD SIDE OF THE SERVICE ELEVATOR IN THE LOWER GALLEY. REMOVED CORRODED SECTION OF FLOORBEAM, FABRICATED AND INSTALLED A NEW SECTION OF FLOORBEAM IN ACCORDANCE WITH SRM Sep 20, 1996 · N151SY · Doug DC1015 · Fuselage Main, Floor BeamSDR SCNA96282Bulkhead · crackedDURING HEAVY MAINTENANCE, FOUND NON-STANDARD REPAIR INSIDE AFT CARGO BAY AT BS 1841, L 48R. REMOVED EXISTING REPAIR AND CLEANED UP DAMAGE, FABRICATED AND INSTALLED A FILLER AND DOUBLER IN ACCORDANCE WITH SRM 53-00-01.Sep 20, 1996 · N151SY · Doug DC1015 · Fuselage Main, BulkheadSDR SCNA96281Frame · crackedDURING HEAVY MAINTENANCE, FOUND NON-STANDARD REPAIR INSIDE AFT CARGO BAY AT BS 1841, L 50L. REMOVED EXISTING REPAIR AND CLEANED UP DAMAGE, FABRICATED AND INSTALLED A FILLER AND DOUBLER IN ACCORDANCE WITH SRM 51-20-00 AND 53-00-01.Sep 20, 1996 · N151SY · Doug DC1015 · Fuselage Main, FrameSDR SCNA96280Frame · crackedDURING HEAVY MAINTENANCE, FOUND NON-STANDARD REPAIR INSIDE AFT CARGO BAY AT BS 1841, L 45R. REMOVED EXISTING REPAIR AND CLEANED UP DAMAGE, FABRICATED AND INSTALLED A FILLER AND DOUBLER IN ACCORDANCE WITH SRM 53-16-01 AND 53-00-01.Sep 20, 1996 · N151SY · Doug DC1015 · Fuselage Main, FrameSDR SCNA96307Ceiling Support · crackedDURING HEAVY MAINTENANCE, FOUND CEILING SUPPORT CRACKED IN THE FORWARD CARGO COMPARTMENT AT BS 919, RBL 67. REMOVED CRACKED CEILING SUPPORT, FABRICATED AND INSTALLED A NEW CEILING SUPORT IN ACCORDANCE WITH SRM 51-00-01 AND SRM 53-00-01.Sep 19, 1996 · N151SY · Doug DC1015 · Fuselage Internal Mounting StructureSDR SCNA96299Skin · dentedDURING HEAVY MAINTENANCE, FOUND A SMOOTH DENT AT BS 765, BELOW LONGERON L-27. FABRICATED AND INSTALLED A DOUBLER IN ACCORDANCE WITH SRM 53-20-00 FIGURE 13.Sep 19, 1996 · N151SY · Doug DC1015 · Fuselage Main, Plate/SkinSDR SCNA96298Bulkhead · crackedDURING HEAVY MAINTENANCE, FOUND A CRACK EXTENDING BEYOND THE STOP DRILL LOCATION IN AN EXISTING REPAIR ON THE BS 1841 BULKHEAD. REMOVED EXISTING REPAIR AND DAMAGED MATERIAL, FABRICATED AND INSTALLED A FILLER AND DOUBLER IN ACCORDANCE WITH SRM 53-00-11 FIGURESep 19, 1996 · N151SY · Doug DC1015 · Fuselage Main, BulkheadSDR SCNA96297Skin · gougedDURING HEAVY MAINTENANCE, FOUND A DENT ON THE LEFT SIDE OF THE FUSELAGE AT BS 560 JUST BELOW THE FLOOR LINE. BLENDED OUT DENT, FABRICATED AND INSTALLED A DOUBLER IN ACCORDANCE WITH SRM 53-20-00 FIGURE 13.Sep 19, 1996 · N151SY · Doug DC1015 · Fuselage Main, Plate/SkinSDR SCNA96296Skin · gougedDURING HEAVY MAINTENANCE, FOUND 3 GOUGES IN THE LEFT SIDE OF THE FUSELAGE AT BS 715, JUST ABOVE THE FLOOR LINE. BLENDED OUT GOUGES IN ACCORDANCE WITH SRM 52-00-01. FABRICATED AND INSTALLED A DOUBLER IN ACCORDANCE WITH SRM 53-20-00.Sep 19, 1996 · N151SY · Doug DC1015 · Fuselage Main, Plate/SkinSDR SCNA96279Skin · corrodedDURING HEAVY MAINTENANCE, FOUND FUSELAGE SKIN CORRODED AT BS 1761, LONGERON 44. REMOVED CORROSION, TRIMMED OUT SKIN, FABRICATED AND INSTALLED A REPAIR IN ACCORDANCE WITH SRM 51-21-01 AND EO 53-5283-1.Sep 19, 1996 · N151SY · Doug DC1015 · Fuselage Main, Plate/SkinSDR SCNA96278Skin · corrodedDURING HEAVY MAINTENANCE, FOUND FUSELAGE SKIN CORRODED AT BS 1721, LONGERON 42. REMOVED CORROSION, TRIMMED OUT SKIN, FABRICATED AND INSTALLED A REPAIR IN ACCORDANCE WITH SRM 51-21-01 AND EO 53-5283-1.Sep 19, 1996 · N151SY · Doug DC1015 · Fuselage Main, Plate/SkinSDR SCNA96277Skin · corrodedDURING HEAVY MAINTENANCE, FOUND FUSELAGE SKIN CORRODED AT BS 1741, LONGERON 44. REMOVED CORROSION, TRIMMED OUT SKIN, FABRICATED AND INSTALLED A REPAIR IN ACCORDANCE WITH SRM 51-21-01 AND EO 53-5283-1.Sep 19, 1996 · N151SY · Doug DC1015 · Fuselage Main, Plate/SkinSDR SCNA96311Skin · chaffedDURING HEAVY MAINTENANCE, FOUND CHAFING SPOTS ON THE LOWER SURFACE OF THE LEFT HAND NUMBER 3 SPOILER. FABRICATED AND INSTALLED A REPAIR ON THE LOWER SURFACE OF THE NUMBER 3 SPOILER PER SRM 51-70-00 AND ENGINEERING AUTHORIZATION EA DC10-57-010.Sep 18, 1996 · N151SY · Doug DC1015 · SpoilersSDR SCNA96312Skin · dentedDURING HEAVY MAINTENANCE, FOUND A DENT IN THE INBOARD FOREFLAP ABOVE AND BEHIND THE MAIN GEAR ON THE RIGHT SIDE. FABRICATED AND INSTALLED A PERMANENT REPAIR IN ACCORDANCE WITH SRM 51-71-00, VOLUME II PAGE 68 AND FIGURE 33.Sep 17, 1996 · N151SY · Doug DC1015 · Trailing Edge FlapsSDR SCNA96310Skin · chaffedDURING HEAVY MAINTENANCE, FOUND CHAFING SPOTS ON THE LOWER SURFACE OF THE LEFT HAND NUMBER 4 SPOILER. FABRICATED AND INSTALLED A REPAIR ON THE LOWER SURFACE OF THE NUMBER 4 SPOILER PER SRM 51-70-00 AND ENGINEERING AUTHORIZATION EA DC10-57-010.Sep 17, 1996 · N151SY · Doug DC1015 · SpoilersSDR SCNA96275Frame · corrodedDURING HEAVY MAINTENANCE, FOUND CORROSION AROUND INSERTS ON THE AFT SIDE OF THE DOOR FRAME IN THE AFT CARGO COMPARTMENT. REMOVED CORROSION, FABRICATED AND INSTALLED A REPAIR IN ACCORDANCE WITH SRM 53-50-00.Sep 17, 1996 · N151SY · Doug DC1015 · Fuselage Miscellaneous StructureSDR SCNA96245Smoke Detector · inoperativeAFT LAV-E SMOKE DETECTOR ON CONTINUOUSLY. REMOVED AND REPLACED SMOKE DETECTOR, OPS CHECKED NORMAL.Sep 3, 1996 · N151SY · Doug DC1015 · Smoke DetectionSDR SCNA96228Skin · corrodedDURING A-CHECK INSPECTION, FIVE DIMPLES WERE NOTED IN LOCALIZED AREAS ON THE EXTERIOR OF THE FUSELAGE SKIN. THE DIMPLES ARE APPROXIMATELY 0.50 INCH IN DIAMETER AND ARE LOCATED AT STATIONS 1721, 1741, AND 1761 BETWEEN STRINGERS 45L AND 48L. INSTALLED A TIME LAug 22, 1996 · N151SY · Doug DC1015 · Fuselage Main, Plate/SkinSDR SCNA96196Check Valve · inoperativeUNABLE TO PRESSURIZE CABIN, DUMPED APPROXIMATELY 30,000 POUNDS OF FUEL AND RETURNED TO LAS. FOUND CHECK VALVE (P/N 7012-505) TO BE INOP IN NUMBER 2 PACK AND A BLOWN AIR CONDITIONING DUCT (P/N 7009-605). REMOVED AND REPLACED BOTH PARTS IAW MM 21-30-0. DUCT LJul 14, 1996 · N151SY · Doug DC1015 · Cabin Cooling SystemSDR SCNA96175Smoke Det · inoperativeFORWARD CARGO SMOKE DETECTOR WOULD NOT TEST. RELAMPED DETECTOR, OPS CHECK OK.Jun 4, 1996 · N151SY · Doug DC1015 · Smoke DetectionSDR SCNA96154Smoke Detector · inoperativeTHE SMOKE DETECTOR IN THE LAV JUST AFT OF DOOR R1 WAS FOUND TO BE INOP. REMOVED AND REPLACED THE SMOKE DETECTOR, OPS CHECK OK.Jun 3, 1996 · N151SY · Doug DC1015 · Smoke DetectionSDR SCNA96039Connector · faultyTHE SMOKE DETECTOR IN LAVATORY 'A' WAS FOUND TO BE INOPERATIVE. REPLACED ELECTRICAL CONNECTOR AT SMOKE DETECTOR. DETECTOR OPS CHECKED NORMAL.Mar 30, 1996 · N151SY · Doug DC1015 · Smoke DetectionSDR SCNA96023Smoke Detector · failedLAVATORY B-SMOKE DETECTOR WILL NOT RESET. REMOVED AND REPLACED SMOKE DETECTOR AND PREFORMED SELF TEST, OPS CHECKED OK.Feb 19, 1996 · N151SY · Doug DC1015 · Smoke DetectionSDR SCNA96013Wire · brokenTHE L-1 DOOR SLIDE PUSH TO TEST DOES NOT ILLUMINATE WHEN PRESSED. REPAIRED BROKEN WIRE AT BATTERY HOLDER AND SLIDE TESTED GOOD.Feb 1, 1996 · N151SY · Doug DC1015 · Equipment/Furnishings WiringSDR SCNA95291Smoke Det Lamp · failedTHE NUMBER 3 CARGO SMOKE DETECTOR WOULD NOT TEST. RELAMPED DETECTOR AND UNIT OPS CHECKED GOOD.Dec 15, 1995 · N151SY · Doug DC1015 · Smoke DetectionSDR SCNA95290Slide Batteries · faultyTHE R-2 DOOR EVACUATION SLIDE WOULD NOT TEST. REMOVED AND REPLACED BATTERIES FOR THE EVACUATION SLIDE AND SELF TESTED IAW MM 25-61-03, OPS CHECKED GOOD.Dec 15, 1995 · N151SY · Doug DC1015 · Emergency EquipmentSDR SCNA95283Skin · corrodedDURING A SCHEDULED INSPECTION, THE FUSELAGE SKIN WAS FOUND BULGING WITH A PULLED FASTENER AT FRAME STATION 1902 BETWEEN LONGERONS 45R AND 48R. THE CAUSE OF THE BULGING SKIN WAS ATTRIBUTED TO CORROSION BETWEEN THE FUSELAGE SKIN AND THE UNDERLYING TITANIUM TEARDec 6, 1995 · N151SY · Doug DC1015 · Fuselage Main, Plate/SkinSDR SCNA95284Pan · crackedDURING A SCHEDULED INSPECTION, THE AFT CARGO DOOR WAS FOUND WITH A .75 INCH CRACK IN THE AFT DOOR PAN. THE CRACK EXTENDED FROM AN EXISTING FASTENER HOLE TO THE AFT EDGE OF THE PAN. THE DAMAGE WAS CUTOUT, A FILLER AND DOUBLER INSTALLED PER DC-10 SRM, VOL 1 CHDec 4, 1995 · N151SY · Doug DC1015 · Cargo/Baggage DoorsSDR SCNA95181Test Light Batt · dischargedTHE R-2 DOOR SLIDE INTEGRITY TEST LIGHT DID NOT ILLUMINATE WHEN PRESSED. REMOVED AND REPLACED TEST BATTERIES, AND SLIDE TESTED GOOD.Sep 1, 1995 · N151SY · Doug DC1015 · Emergency EquipmentSDR SCNA95151Eel Power Supply · failedFOUND THE AFT CABIN EMERGENCY FLOOR LIGHTS INOPERATIVE. REMOVED AND REPLACED AFT CABIN POWER SUPPLY PER MM 33-51-01. LIGHTS TESTED GOOD.Jul 15, 1995 · N151SY · Doug DC1015 · Emergency LightingSDR SCNA95054Smoke Detector · failedLAVATORY J SMOKE DETECTOR CONTINUOUSLY GOING OFF. REMOVED AND REPLACED SMOKE DETECTOR IN LAV J. OPS CHECKS GOOD IAW MM 26-29-00.Apr 9, 1995 · N151SY · Doug DC1015 · Smoke DetectionSDR SCNA95034Eel Power Supply · failedFORWARD CABIN EMERGENCY LIGHTS FAIL TEST. REPLACED FORWARD CABIN EMERGENCY LIGHTS POWER SUPPLY AND OPS CHECK GOOD.Mar 8, 1995 · N151SY · Doug DC1015 · Emergency LightingSDR SCNA95021Eel Power Pack · failedMSP - FORWARD CABIN EMERGENCY TRACK LIGHTING INOPERATIVE IN BOTH AISLES. REMOVED AND REPLACED FORWARD SECTION BATTERY POWER PACK, SPLICED BROKEN WIRES, EMERGENCY FLOOR TRACK LIGHTING OPS CHECKED GOOD. (X)Feb 11, 1995 · N151SY · Doug DC1015 · Emergency LightingSDR SCNA95015Hyd Line · leakingMSP - NR 2 HYDRAULIC SYSTEM PRESSURE LINE CHAFING WITH STANDBY RUDDER PRESSURE LINE CAUSING A LEAK BELOW NR 2 INLET DUCT. REPLACED BOTH LINES AND LEAK CHECKED GOOD. (X)Jan 22, 1995 · N151SY · Doug DC1015 · Hydraulic System, Auxiliary
Back to N151SY, cancelled Jan 15, 2002