N151SY, cancelled Jan 15, 2002
Service difficulty reports · 136
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N151SY' AND deregistration_id = 'N151SY-2002-01-15' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N151SY' AND deregistration_id = 'N151SY-2002-01-15' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SCNA99539Angle · corrodedDURING A HEAVY MAINTENANCE CHECK IN THE AFT CARGO COMPARTMENT CORROSION WAS FOUND AT STA 1964 AT LBL 50 TO RBL 50. REMOVED AFT THRESHOLD ANGLE AND FABRICATED NEW THRESHOLD ANGLE AND INSTALLED.SDR SCNA99538Web · crackedDURING A HEAVY MAINTENANCE CHECK IN THE CARGO BAY STA 1541 AT LGR 43L WAS FOUND TO HAVE A 1 INCH CRACK IN THE WEB UNDER THE CARGO ROLLER TRACKS. REMOVED WEB AND FABRICATED A NEW ONE PER SRM 512101 AND 513000.SDR SCNA99104N1 Sensor · inoperativeAIRCRAFT ABORTED TAKEOFF AT 120 KNOTS AS NUMBER TWO ENGINE DIDN'T MAKE REDUCED N1. OPERATIONALLY CHECKED THE NUMBER TWO ENGINE IAW DC-10 MM 710000. OPERATIONALLY CHECKED AIRCRAFT PER MM 055700 AFTER HIGH ENERGY STOP. REMOVED AND REPLACED THE NUMBER TWO ENGISDR SCNA99094Coffeemaker · failedDURING FLIGHT, NUMBER THREE COFFEEMAKER SPARKED THEN THE GALLEY POWER TRIPPED OFF LINE. GALLEY COFFEEMAKER CIRCUIT BREAKERS THEN PULLED. REMOVED AND REPLACED THE COFFEMAKER AND CHECKED ALL ELECTRICAL TERMINALS. RESET CIRCUIT BREAKER AND OPERATIONALLY CHECKSSDR SCNA99079Light · inoperativeDURING A LINE MAINTENANCE CHECK, THE EMERGENCY PATH LIGHTING ON THE RIGHT SIDE AT SEAT ROW 37 WAS FOUND TO BE INOPERATIVE. REMOVED AND REPLACED THE EMERGENCY PATH LIGHTING ASSEMBLY AT SEAT ROW 37 ON THE RIGHT SIDE. OPERATIONALLY CHECKS GOOD.SDR SCNA99057Cover · out of positionDURING A LINE MAINTENANCE CHECK, THE L1 DOOR WOULD NOT RELEASE FROM THE DOOR OPENING. FOUND THE LOWER ESCAPE SLIDE COVER JAMMED INTO DOOR FRAME WITH ENOUGH PRESSURE TO LOCK THE DOOR INTO THE FRAME. OBSTRUCTING DOOR SLIDE COVER REMOVED FROM DOOR FRAME AND DOOSDR SCNA99026Wire · failedDURING A LINE MAINTENANCE CHECK, THE EMERGENCY EXIT TRACK AFT OF THE R1 DOOR WAS FOUND TO BE INOPERATIVE. REPAIRED WIRES ON THE EMERGENCY EXIT TRACK, OPERATIONALLY CHECKS GOOD.SDR SCNA99002Wire · pinchedDURING FLIGHT, THE OXYGEN MASKS IN THE FORWARD CABIN EJECTED. TROUBLESHOT PROBLEM TO BE A PINCHED MUX SYSTEM CABLE AT SEAT ROWS 6ABC AND 7ABC. REPLACED THE MUX CABLE AND RESET ALL OXYGEN MASKS THAT DROPPED. PERFORMED OXYGEN DROP TEST PER MM 35-20-00. PASSESDR SCNA99001Power Supply · inopDURING A LINE MAINTENANCE CHECK, THE LEFT OVERWING EMERGENCY POWER SUPPLY FAILED TEST. REMOVED AND REPLACED THE LEFT OVERWING EMERGENCY POWER SUPPLY. OPERATIONALLY CHECKS GOOD.SDR SCNA98156Valve · failedDURING CLIMBOUT, CREW REPORTED UNABLE TO MAINTAIN CABIN ALTITUDE. AT 31,000 FEET THE ALTITUDE WARNING HORN SOUNDED AND DESCENDED TO 19,000 FEET BEFORE THE CABIN WAS CONTROLLABLE. DIVERTED AIRCRAFT TO DEN. FOUND THE NUMBER THREE PACK DUCT BLOWN OFF THE BACK SDR SCNA98122Wall · delaminatedDURING A MAINTENANCE CHECK, THE CENTER WALL BETWEEN THE P LIFT AND C LIFT WAS FOUND TO BE DELAMINATED. REMOVED AND REPLACED THE DAMAGED SECTION OF HONEYCOMB. FABRICATED AND INSTALLED A DOUBLER IAW MDC-10 SRM 517100.SDR SCNA98123Intercostal · corrodedDURING A MAINTENANCE CHECK AN INTERCOSTAL THAT RUNS OUTBOARD TO THE RIGHT OF THE P LIFT WAS FOUND CORRODED. REMOVED CORRODED INTERCOSTAL AND FABRICATED A NEW SECTION OF INTERCOSTAL. TREATED AND PRIMED AND INSTALLED IAW SRM 537000.SDR SCNA98112Slide · failed testDURING A LINE MAINTENANCE CHECK, THE R3 DOOR SLIDE PRESS TO TEST LIGHT WAS CONTINUOUSLY ILLUMINATED. FOUND SLIDE PRESSURE TO BE LOW AND REMOVED AND REPLACED THE EMERGENCY SLIDE IAW MM 256101. SLIDE PACK PRESSURE INDICATOR TESTS NORMAL.SDR SCNA98083Wire · brokenDURING A LINE MAINTENANCE CHECK, THE MID CABIN RIGHT SIDE EMERGENCY EXIT LIGHT WAS FOUND TO BE INOPERATIVE. FOUND A BROKEN WIRE. WIRE REPAIRED AND LIGHTS OPERATIONALLY CHECK GOOD IN ACCORDANCE WITH 3300.SDR SCNA98509Latch Solenoid · inoperativeDURING HEAVY CHECK, THE FLIGHT ATTENDANT L-4 OXYGEN BOX WOULD NOT OPEN DURING OXYGEN DROP CHECK. REMOVED AND REPLACED LATCH SOLENOID AT L-4 FLIGHT ATTENDANT STATION OXYGEN BOX PER MM 35-20-00, OPERATIONAL CHECKS GOOD PER MM 35-20-00.SDR SCNA98508Seat Track · corrdedDURING HEAVY CHECK IN THE WASTE TANK COMPARTMENT RIGHT TUNNEL 186 STATION 2007 AT THE FLOOR LEVEL OUTER FLOORBEAM WAS CORRODED ON THE END. MATERIAL VERIFICATION TO BE 7075 T6511, FOR EACH SEAT TRACK AND MATERIAL VERIFIED FOR EACH U CHANNEL SPLICE TO BE 7075 TSDR SCNA98507Spar Cap · crackedDURING HEAVY CHECK, THE RIGHT HAND HORIZONTAL STABILIZER XFS77 XE57 WAS FOUND TO HAVE A 2 INCH CRACK AS VIEWED FROM INTERSPAR BOX ON TOP OF FORWARD SPAR AT JUNCTION OF FUSELAGE SKIN ON FORWARD SPAR. MATERIAL VERIFIED 7075 T6 .125 FOR REPAIR DOUBLER -11 AND 1SDR SCNA98506Stringer · corrodedDURING HEAVY CHECK, FORWARD CARGO SUMP AREA BETWEEN STA 899 AND 919 STR 52 WAS FOUND TO HAVE LEVEL 2 CORROSION. MATERIAL LOSS IS OUT OF LIMITS. MATEIRIAL VERIFIED AS 7075.160. FABBED TWO EACH STRINGERS TWO EACH SPLICE AND TWO EACH FILLERS PER SRM 53-10-00 FSDR SCNA98505Rib · crackedDURING HEAVY CHECK, THE RIGHT HAND LEADING EDGE INTERNAL HAS A THREE INCH CRACK ON THE LOWER RIB APPROX AT STATION 491. FABRICATED TWO EACH DOUBLERS 7975 .063 AND 7075 .025 AND FILLER 7075 T6 .040 HEAT TREATED AND PRIMED IAW SRM 51-21-01 AND INSTALLED IAW SRMSDR SCNA98504Bracket · crackedDURING HEAVY CHECK, RIGHT HAND LATERAL CONTROL SPOILER MIXER BRACKET HAS A .25 CRACK NOTED ON AFT SPOILER BRACKET ON AFT SIDE AT TRANSITION RADII BETWEEN THE LEGS AND BODY OF THE BRACKET INBOARD LEG. REPLACED WITH A NEW AND IMPROVED MIXER BRACKET P/N APH7275-SDR SCNA98503Support · crackedDURING HEAVY CHECK, THE REMOVAL OF A FLOOR PANEL TO FACILITATE MAINTENANCE REVEALED A CRACKED FLOOR SUPPORT UNDER THE PATIO FLOOR PANEL. FABRICATION OF ONE DOUBLER, 2024 T3 .040 AND ONE FILLER 2029 T3 .032 PER SRM 53-00-01 AND TREATED PER SRM 51-21-01 AND INSSDR SCNA98502Support · corrodedDURING HEAVY MAINTENANCE VISIT, CORROSION WAS FOUND ON THE RIGHT TUNNEL 186 END AT FLOOR SUPPORT BEAM END IN THE WASTE TANK COMPARTMENT, APPROXIMATELY STATION 2007, FLOOR LEVEL. REMOVED CORRODED SECTION AND SPLICED IN A REPAIR IN ACCORDANCE WITH SRM 53-70-00,SDR SCNA98501Angle · corrodedDURING HEAVY MAINTENANCE VISIT, CORROSION WAS FOUND ON THE RIGHT TUNNEL LEG IN THE WASTE TANK COMPARTMENT, APPROXIMATELY STATION 2007, FLOOR LEVEL. REMOVED CORRODED SECTION AND SPLICED IN A REPAIR IN ACCORDANCE WITH SRM 53-40-00, FIGURE 16.SDR SCNA98031Smoke Detector · malfunctionedTWO PASSENGERS WERE CAUGHT SMOKING IN THE LAVATORIES AND THE SMOKE DETECTORS FAILED TO GO OFF. ALL LAVATORY SMOKE DETECTORS SUBJECTED TO LIVE SMOKE TEST WITH NO FAULT FOUND. SMOKE DETECTORS INSPECTED FOR TAMPERING AND NO DEFECTS NOTED.SDR SCNA98029Fastener · shearedDURING A SCHEDULED MAINTENANCE INSPECTION, THE AFT LOWER RIGHT HAND FASTENER WAS FOUND SHEARED OFF ON THE NUT SIDE FOR THE NUMBER FOUR BANJO FITTING ATTACHMENT. THE AREA WAS REWORKED IN ACCORDANCE WITH SERVICE BULLETIN DC10-55-023 REVISION TWO.SDR SCNA97296Power Supply · inoperativeTHE OVERWING EMERGENCY LIGHT POWER SUPPLY DOES NOT PASS THE EMERGENCY LIGHT TEST. REMOVED AND REPLACED THE POWER SUPPLY AND BATTERY PACK, SYSTEM TESTED GOOD.SDR SCNA97295Pneumatic Valve · lack of lubeWHILE CONDUCTING A TEST SLIDE/RAFT DEPLOYMENT AT THE L-3 DOOR, THE DOOR WOULD NOT OPEN PNEUMATICALLY. DOOR WAS OPERATED MANUALLY AND THE SLIDE/RAFT DEPLOYED NORMALLY. LUBRICATED OVERIDE HANDLE AND PNEUMATIC VALVE FOR THE L-3 DOOR, DOOR OPS CHECKED NORMAL.SDR SCNA97136Batteries · dischargedTHE L-3 DOOR SLIDE PRESS TO TEST LIGHT WAS FOUND TO BE DIM. REMOVED AND REPLACED TEST LIGHT BATTERIES. SLIDE TESTED GOOD.SDR SCNA97086Light · inoperativeR1 DOOR FORWARD EMERGENCY EXIT LIGHT WAS FOUND INOP. RELAMPED EMERGENCY LIGHT AND FUNCTIONALLY TESTED IN ACCORDANCE WITH MM 33-00. NO DISCREPANCIES NOTED.SDR SCNA97084Smoke Det Lamp · failedPOSITION 2 CARGO SMOKE DETECTOR DID NOT TEST. RELAMPED SMOKE DETECTOR AND FUNCTIONALLY TESTED WITH NO DISCREPANCIES NOTED.SDR SCNA97061Coffeemaker · dirtyDURING FLIGHT, THERE WAS AN ELECTRICAL SMOKE SMELL IN THE AFT GALLEY. TURNED GALLEY POWER OFF AND SMELL WENT AWAY. FOUND NUMBER 7 COFFEE MAKER BASE DIRTY, CLEANED BASE AND OPS CHECKED GOOD.SDR SCNA97053Power Supply · inoperativeFORWARD OVERHEAD EMERGENCY LIGHT POWER SUPPLY FAILED SELF TEST. REMOVED AND REPLACED POWER SUPPLY IN ACCORDANCE WITH 33-51-01 AND OPS CHECKED GOOD.SDR SCNA97008Light · inoperativeFORWARD CABIN EMERGENCY TRACK LIGHTING WAS FOUND INOP IN AFT HALF OF FORWARD CABIN. REPAIRED SHORTED SUPPLY WIRING AT SEAT 8HJK, OPS CHECKED GOOD.SDR SCNA97005Switch Assy · inoperativeL1 DOOR EMERGENCY SLIDE PUSH TO TEST BUTTON WAS INOP. REMOVED AND REPLACED COMPLETE BATTERY, PLUG AND SWITCH ASSEMBLY, OPS CHECKED GOOD.SDR SCNA96382Smoke Detector · failedTHE NUMBER 1 SMOKE DETECTOR WOULD NOT TEST. FOUND LAMP BURNED OUT ON NUMBER 1 AFT CENTER CARGO SMOKE DETECTOR. RELAMPED AND DETECTOR, TESTED GOOD.SDR SCNA96293Skin · damagedDURING HEAVY MAINTENANCE, FOUND LIP TORN ON CUT OUT, SECOND HINGE FROM OUTBOARD END ON LEFT HAND ELEVATOR. REMOVED DAMAGED AREA, FABRICATED AND INSTALLED DOUBLER IN ACCORDANCE WITH SRM 55-21-01 AND SRM 55-00-01.SDR SCNA96292Skin · damagedDURING HEAVY MAINTENANCE, FOUND LIP BENT AND TORN ON CUT OUT, SECOND HINGE FROM OUTBOARD END ON RIGHT HAND ELEVATOR. REMOVED DAMAGED AREA, FABRICATED AND INSTALLED DOUBLER IN ACCORDANCE WITH SRM 55-21-01 AND SRM 55-00-01.SDR SCNA96295Angle · crackedDURING HEAVY MAINTENANCE, FOUND A CRACKED L-ANGLE IN THE NUMBER 1 PYLON AT APPROXIMATE STATION 272 OUTBOARD END, IN BACK AND ABOVE PRECOOLER. REMOVED EXISTING ANGLE, FABRICATED AND INSTALLED A NEW ANGLE IN ACCORDANCE WITH SRM 54-71-02, SRM 51-33-00 AND SRM 51SDR SCNA96272Strut · scratchedDURING HEAVY MAINTENANCE, FOUND SCRATCHES ON THE INNER AND OUTER CYLINDERS OF THE LEFT MAIN LANDING GEAR. ALSO, FOUND DAMAGED UPPER AND LOWER BEARINGS. REMOVED AND REPLACED THE LEFT MAIN LANDING GEAR SHOCK STRUT ASSEMBLY IN ACCORDANCE WITH CHAPTER 32 OF THESDR SCNA96271Strut · scratchedDURING HEAVY MAINTENANCE, FOUND SCRATCHES IN THE CHROME ON THE OUTER CYLINDER OF THE RIGHT MAIN LANDING GEAR. REMOVED AND REPLACED THE RIGHT MAIN LANDING GEAR OUTER CYLINDER IN ACCORDANCE WITH CHAPTER 32 OF THE MAINTENANCE MANUAL.SDR SCNA96294Skin · dentedDURING HEAVY MAINTENANCE, FOUND A DENT APPROXIMATELY 12 INCHES FROM THE INBOARD END OF THE RIGHT HAND HORIZONTAL STABILIZER. REMOVED DAMAGED AREA, FABRICATED AND INSTALLED A REPAIR FILLER AND DOUBLER IN ACCORDANCE WITH SRM 55-10-00 AND 53-30-10.SDR SCNA96274Angle · brokenDURING HEAVY MAINTENANCE, FOUND NON STANDARD INSTALLATION OF SUPPORT ANGLE AT BS 1701 RBL 5. FABRICATED AND INSTALLED NEW SUPPORT ANGLE IN ACCORDANCE WITH SRM 53-00-01 AND SRM 51-31-01.SDR SCNA96273Angle · brokenDURING HEAVY MAINTENANCE, FOUND BROKEN PANEL SUPPORT ANGLE AT BS 1801 RBL 32. FABRICATED AND INSTALLED NEW SUPPORT ANGLE IN ACCORDANCE WITH SRM 53-00-01 AND SRM 51-31-01.SDR SCNA96309Frame · crackedDURING HEAVY MAINTENANCE, FOUND A CRACK IN THE LONGERON HOLE FOR LONGERON 48L AT BS 1501. REMOVED DAMAGED SECTION, FABRICATED AND INSTALLED REPAIR DOUBLER IN ACCORDANCE WITH SRM 53-30-00 AND ENGINEERING AUTHORIZATION EZ DC10-53-012.SDR SCNA96306Floorbeam · corrodedDURING HEAVY MAINTENANCE, FOUND CORROSION ON THE FLOORBEAM AT BS 1887, LBL 30 AND RBL 24. REMOVED CORRODED SECTIONS, FABRICATED AND INSTALLED FILLERS AND DOUBLERS IN ACCORDANCE WITH SRM 51-21-00, SRM 53-00-01 AND ENGINEERING AUTHORIZATION EA DC10-53-014.SDR SCNA96304Floorbeam · corrodedDURING HEAVY MAINTENANCE, FOUND CORROSION ON THE FLOORBEAM AT BS 735 TO BS 737 RIGHT HAND SIDE OF THE LOWER GALLEY. REMOVED CORRODED MATERIAL, FABRICATED AND INSTALLED A FILLER AND DOUBLER IN ACCORDANCE WITH SRM 53-00-01 AND ENGINEERING AUTHORIZATION EA DC1SDR SCNA96303Floorbeam · corrodedDURING HEAVY MAINTENANCE, FOUND CORROSION ON THE FLOORBEAM AT BS 775 TO 830, RIGHT HAND SIDE OF THE LOWER GALLEY. REMOVED CORRODED MATERIAL, FABRICATED AND INSTALLED A FILLER AND DOUBLER IN ACCORDANCE WITH SRM 53-00-01 AND ENGINEERING AUTHORIZATION EA DC10-53SDR SCNA96305Floorbeam · corrodedDURING HEAVY MAINTENANCE, FOUND CORROSION ON THE FLOORBEAM AT BS 750 RIGHT HAND SIDE OF THE LOWER GALLEY. REMOVED CORRODED MATERIAL, FABRICATED AND INSTALLED A FILLER AND DOUBLER IN ACCORDANCE WITH SRM 53-00-01 AND ENGINEERING AUTHORIZATION EA DC10-53-13.SDR SCNA96302Floorbeam · corrodedDURING HEAVY MAINTENANCE, FOUND CORROSION ON THE FLOORBEAM AT BS 685 IN THE LOWER GALLEY. REMOVED CORRODED MATERIAL, FABRICATED AND INSTALLED A FILLER AND DOUBLER IN ACCORDANCE WITH SRM 53-00-01.SDR SCNA96301Floorbeam · corrodedDURING HEAVY MAINTENANCE, FOUND CORROSION ON THE FLOORBEAM AT BS 823 IN THE FORWARD GALLEY. REMOVED CORROSION, FABRICATED AND INSTALLED A FILLER AND DOUBLER IN ACCORDANCE WITH SRM 53-00-01.