N154SY, cancelled Oct 26, 2004

Service difficulty reports · 22

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N154SY' AND deregistration_id = 'N154SY-2004-10-26'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR SCNA00096Power Supply · inoperativeAFT CABIN EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED AFT CABIN POWER SUPPLY AND BATTERY PACK, OPERATIONAL CHECKS GOOD.Aug 30, 2000 · N154SY · Doug DC1015 · Emergency LightingSDR SCNA00092Power Supply · inoperativeDURING A MAINTENANCE LINE CHECK, THE AFT EMERGENCY LIGHT POWER SUPPLY FAILED. REMOVED AND REPLACED THE AFT EMERGENCY LIGHT POWER SUPPLY.Aug 29, 2000 · N154SY · Doug DC1015 · Emergency LightingSDR SCNA00053Slide · failedDURING A ROUTINE MAINTENANCE CHECK, THE R4 DOOR SLIDE WAS CHECKED FOR FOR PROPER INFLATION AND SERVICIABILITY. THE SLIDE DID NOT STAY INFLATED AND SHOWED SIGNS OF DRY ROT ON THE UNDERSIDE OF THE SLIDE, AS WELL AS A SPLIT IN THE MIDDLE OF THE SLIDE PATH. THE Jun 7, 2000 · N154SY · Doug DC1015 · Escape SlideSDR SCNA00052Line · rupturedAFTER TAKEOFF FROM PVR, THE LANDING GEAR HANDLE WOULD NOT MOVE FROM THE DOWN POSITION. THE CREW RETURNED TO POINT OF ORIGIN. A HYDRAULIC LINE WAS FOUND RUPTURED ON THE LT MLG BOOGIE TRIM CYLINDER. THE HYDRAULIC LINE WAS REMOVED AND REPLACED WITH A TEMPORARYJun 5, 2000 · N154SY · Doug DC1015 · Hydraulic System, MainSDR SCNA00025Light · inoperativeDURING A LINE MAINTENANCE CHECK, THE EMERGENCY PATH LIGHTING BETWEEN RIGHT HAND ROWS 15 TO 18 WAS FOUND TO BE INOPERATIVE. THE EMERGENCY PATH LIGHTING FROM RIGHT HAND ROWS 15 TO 18 WAS REMOVED AND REPLACED. OPERATIONALLY CHECKED GOOD IAW MM 335211.Apr 3, 2000 · N154SY · Doug DC1015 · Emergency LightingSDR SCNA99116Bulb · failedDURING A LINE MAINTENANCE CHECK, AN EMERGENCY TRACK LIGHT BY SEAT ROW 6 WAS FOUND TO BE INOPERATIVE. REMOVED AND REPLACED THE LIGHT BULB IN THE EMERGENCY TRACK BY SEAT ROW 6 RIGHT SIDE. OPERATIONALLY CHECKS GOOD.Sep 1, 1999 · N154SY · Doug DC1015 · Emergency LightingSDR SCNA99080Light · inoperativeDURING A LINE MAINTENANCE CHECK THE FORWARD CABIN OVERWING EMERGENCY EXIT LIGHTS WERE FOUND TO BE INOPERATIVE. REMOVED AND REPLACED BATTERY ASSEMBLY AND FOUND A SHORT IN THE WIRING IN THE RIGHT SIDEWALL MID CABIN. OPERATIONALLY CHECKS GOOD.Jun 1, 1999 · N154SY · Doug DC1015 · Emergency LightingSDR SCNA99509Switch · failedDURING A HEAVY MAINTENANCE VISIT, DURING COMPLETION OF A CABIN LEAK CHECK THE ALTITUDE WARNING HORN FAILED TO GO OFF WHEN THE CABIN ALTITUDE REACHED 12,000 FT. REMOVED AND REPLACED THE CABIN ALTITUDE SWITCH AND THE SYSTEM OPERATIONALLY CHECKS GOOD IAW DC10 MMMay 10, 1999 · N154SY · Doug DC1015 · Cabin Pressure SensorSDR SCNA99508Sensor · misinstalledDURING A HEAVY MX CHECK TEST FLT, THE LT MAIN GEAR UNSAFE RED LIGHT ILLUM WHILE ROTATING AND EXTINGUISHED IN FLIGHT. THE CREW TROUBLESHOT AND RETURNED TO POINT OF ORIGIN. THE FLT CREW VERIFIED THE DOWN POSITION WITH THE VIEWING PORTS, BRIEFED THE PASSENGERS May 10, 1999 · N154SY · Doug DC1015 · Landing Gear Position and WarningSDR SCNA99506Angle · corrodedDURING A HEAVY MAINTENANCE CHECK, THE 'L' ANGLE AT STATION 567 TO 595 AT LONGERON 44L WAS FOUND TO HAVE CORROSION AND MATERIAL LOSS WAS GREATER THAN 20 PERCENT THE ORIGINAL THICNESS WAS .090 AND FOUR AREAS AFTER WERE .060 AND .074 AND .072 AND .073. THE SUBJMay 10, 1999 · N154SY · Doug DC1015 · Fuselage Miscellaneous StructureSDR SCNA99505Spar · crackedDURING A HEAVY MAINTENANCE CHECK, THE LEFT HORIZONTAL STABILIZER OUTBOARD SECTION UPPER SPAR CAP FORWARD WAS FOUND CRACKED AT THE FORWARD CLOSING RIB PLANE THE CRACK WAS APPROXIMATELY 4.40 INCHES WHICH EXCEED ALLOWABLE LIMITS PER SB DC10 55-24. THE SUBJECT SPMay 10, 1999 · N154SY · Doug DC1015 · Horizontal Stabilizer, Spar/RibSDR SCNA99504Skin · chafedDURING A HEAVY MAINTENANCE CHECK, THE RIGHT LEADING EDGE SKIN ARB1074 WAS FOUND TO BE CHAFED AT STA XOS 551 TO XOS 555 WITH .043 REMAINING OF ORIGINAL THICKNESS OF .063. THE SUBJECT LEADING EDGE WAS REPAIRED PER SRM 571000 FIG 15 AND EO 57-5678-1.May 9, 1999 · N154SY · Doug DC1015 · Wing, Plate/SkinSDR SCNA99503Switch · failedDURING A HEAVY MAINTENANCE CHECK, 2 ANEROID SWITCHES FOR THE PASSENGER OXYGEN SYSTEM FAILED TEST FOR SCA WORK CARD X1036. THE SUBJECT ANEROID SWITCHES 2 WERE REMOVED AND REPLACED PER MM 352102, OPERATION CHECK WAS GOOD.May 9, 1999 · N154SY · Doug DC1015 · Passenger Oxygen SystemSDR SCNA99507Battery Pack · dischargedDURING A HEAVY MAINTENANCE CHECK, THE EMERGENCY PATH LIGHTING WAS FOUND TO BE INOPERATIVE FROM SEAT 8L TO 15L AND 8R TO 15R. REMOVED AND REPLACED THE BATTERY PACK PER MEXICANA EO 1033014, OPERATIONAL CHECK GOOD.May 7, 1999 · N154SY · Doug DC1015 · Emergency LightingSDR SCNA99502Support · crackedDURING A HEAVY MAINTENANCE CHECK, AFT GALLEY FLOOR SUPPORT AT STA 1902 WAS FOUND TO BE CORRODED ON UPPER AND LOWER SURFACES RHX=8 AND BARE METAL X=1 TO X=23 CRACKS WERE FOUND AT FOOT ATTACHMENTS. FABBED NEW FLOOR SUPPORT INSTALLED PER SRM 513501.Apr 21, 1999 · N154SY · Doug DC1015 · Fuselage Miscellaneous StructureSDR SCNA99501Support · corrodedDURING A HEAVY MAINTENANCE CHECK, AFT GALLEY FLOOR SUPPORT AT STA 1910 WAS FOUND TO BE CORRODED BETWEEN X=27.5 AND X=MINUS 27.5 RT. REMOVED CORROSION FOUND TO BE OUT OF LIMITS FABBED STRAP FOR FLOOR PANEL SUPPORT TREATED PRIMED AND INSTALLED PER SRM REFS 5121Apr 18, 1999 · N154SY · Doug DC1015 · Fuselage Miscellaneous StructureSDR SCNA99500Support · crackedDURING A HEAVY MAINTENANCE CHECK, 2EA FLOOR SUPPORTS STA Y=1986 CL=0 AND X+27.5 ARE CRACKED AT INBD ENDS AND ALSO WERE FOUND CORRODED. REMOVED FABRICATED ALODINED PRIMED AND INSTALLED FLOOR SUPPORTS 2EA PER SRM 511000 512101 AND 513000.Apr 18, 1999 · N154SY · Doug DC1015 · Fuselage Miscellaneous StructureSDR SCNA99047Sensor · failedDURING A LINE MAINTENANCE CHECK, THE RIGHT STALL WARNING FAILED THE SELF TEST. REMOVED AND REPLACED THE ANGLE OF ATTACK SENSOR IAW MM 223301. SYSTEM OPERATIONALLY CHECKS GOOD.Mar 11, 1999 · N154SY · Doug DC1015 · Stall Warning SystemSDR SCNA99016Coalescer · contaminatedDURING CLIMB, CABIN FILLED WITH SMOKE. COMPLIED WITH COM AND SMOKE STOPPED WHEN NR 2 PNEUMATIC SUPPLY AND NR 2 PACK SELECTED TO OFF. DIVERTED AIRCRAFT TO ORD FOR A PRECAUTIONARY LANDING. FOUND NR 3 ENGINE WITH NR 3 PACK ON CAUSING OIL FUMES IN THE CABIN AT Jan 17, 1999 · N154SY · Doug DC1015 · Humidity Control SystemSDR SCNA98147Smoke Detector · no testDURING A LINE MAINTENANCE CHECK, THE NUMBER 4 CARGO SMOKE DETECTOR DID NOT TEST. REMOVED AND REPLACED THE SMOKE DETECTOR, OPERATIONALLY CHECKED GOOD.Dec 4, 1998 · N154SY · Doug DC1015 · Smoke DetectionSDR SCNA98091Power Supply · inoperativeDURING A LINE MAINTENANCE CHECK, THE MID CABIN EMERGENCY LIGHTING POWER SUPPLY FAILED SELF TEST. REMOVED AND REPLACED MID CABIN EMERGENCY LIGHTING (OVERHEAD) POWER SUPPLY AND BATTERY. EMERGENCY LIGHTING BITE TESTS GOOD AND OPERATIONALLY CHECKS NORMAL.Aug 14, 1998 · N154SY · Doug DC1015 · Emergency LightingSDR SCNA98079Battery · dischargedDURING A LINE MAINTENANCE CHECK, THE EMERGENCY LIGHT TEST FROM THE COCKPIT FAILS TEST. REMOVED AND REPLACED BOTH BATTERY CHARGER UNIT AND BATTERY IN AFT POSITION. SYSTEM OPERATIONALLY CHECKS NORMAL.Jul 23, 1998 · N154SY · Doug DC1015 · Emergency Lighting
Back to N154SY, cancelled Oct 26, 2004