N16201, cancelled Nov 16, 1998
Service difficulty reports · 25
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N16201' AND deregistration_id = 'N16201-1998-11-16' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N16201' AND deregistration_id = 'N16201-1998-11-16' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA9801218Accessory Unit · inoperativeTHE GEAR HANDLE STOPPED IN THE OFF POSITION WHEN RAISING THE GEAR AFTER TAKEOFF. THE GEAR TRIGGER WAS PULLED AND THE GEAR CAME UP. MAINTENANCE REMOVED AND REPLACED THE LANDING GEAR ACCESSORY UNIT. TESTS WERE CONDUCTED IAW MM 32-09-200 AND ALL CHECKED GOOD.SDR CALA9601797Window Frame · corrodedINSPECTION FOUND FORWARD LOWER CORNER OF NR 4 RT CABIN WINDOW FRAME CORRODED. THE WINDOW FRAME WAS REMOVED AND A NEW FRAME WAS FABRICATED AND INSTALLED IAW SRM 51-30-2 AND 51-30-5.SDR CALA9601796Skin · crackedINSPECTION FOUND .5 INCH CRACKS IN LT FUSELAGE SKIN AT BS 188 TO 251, WL 207 TO 234. THE AREA WAS REPAIRED IAW SRM 51-30-2, BAC DRAWING NR 65-18420, AND EA 5310-01188.SDR CALA9601791Floorbeam · corrodedINSPECTION FOUND CABIN FLOORBEAM CORRODED ON UPPER CHORD AT STA 294.5 FROM RBL 20 TO LBL 20. THE CORRODED SECTION OF FLOORBEAM WAS REMOVED, A NEW FLOORBEAM WAS FABRICATED AND INSTALLED IAW SRM 51-20-1, 51-10-2 AND 51-30-2.SDR CALA9601790Skin · crackedINSPECTION FOUND A 2 INCH CRACK IN FUSELAGE SKIN AT BS 755, STRINGER 19R. THE CRACKED AREA WAS REMOVED IAW SRM 53-30-3. A DOUBLER WAS FABRICATED AND INSTALLED IAW SRM 53-30-3, 51-10-2 AND 51-30-2.SDR CALA9601789Skin · corrodedINSPECTION FOUND EXTERNAL FUSELAGE SKIN LAP BULGED AND ONE FASTENER SHEARED AT FS 380, STRINGER 26R. THE CORROSION WAS REMOVED IAW SRM 51-10-6. FILLER AND DOUBLER WERE FABRICATED AND INSTALLED IAW SRM 53-30-2, 51-10-2, 53-30-2 AND 51-30-2.SDR CALA9601788Stringer · corrodedINSPECTION FOUND FUSELAGE STRINGER 24L CORRODED FROM FS 970 TO 1000. THE CORRODED SECTION OF STRINGER WAS REMOVED IAW SRM 51-10-6. STRINGER REPAIR PARTS WERE FABRICATED AND INSTALLED IAW SRM 53-10-3, 51-10-2 AND 51-30-2.SDR CALA9601787Skin · corrodedINSPECTION FOUND NLG WHEEL WELL UPPER SKIN CORRODED AFT OF ACCESS, STA 240. THE SKIN WAS REPAIRED IAW ECRA 5310-03378.SDR CALA9601846Bear Strap · corrodedINSPECTION FOUND E AND E DOOR CUTOUT BEAR STRAP CORRODED AT FORWARD SIDE OF CUTOUT. STRINGER 29 WAS REMOVED AND CORROSION WAS REMOVED FROM SKIN AND BEAR STRAP IAW SRM 51-10-6. A REPAIR SECTION WAS FABRICATED AND INSTALLED IAW SRM 51-40-3 AND 51-30-2.SDR CALA9601845Skin · corrodedINSPECTION FOUND NOSE WHEEL WELL CUTOUT AFT RT CORNER HAD CORRODED SKIN AND STRESSED FASTENERS. LOWER LOBE SKINS WERE CUT AND REMOVED FROM STA 253 TO 312. THE LOWER CHORD AT STA 294.5 WAS REMOVED AND REPLACED IAW BAC DRAWING 65-45808. A SPLICE WAS FABRICATESDR CALA9601786Stringer · crackedINSPECTION FOUND A 1 INCH CRACK AT STRINGER 7R FASTENER ON RT WING UPPER SURFACE, WBL 200. A REPAIR STRAP WAS FABRICATED AND INSTALLED IAW SRM 51-10-2 AND ECRA 5710-01765.SDR CALA9601844Skin · corrodedINSPECTION FOUND FUSELAGE EXTERIOR SKIN LAP CORRODED AT STA 540, STRINGER 26L. REPAIR FILLER AND DOUBLER WERE FABRICATED AND INSTALLED IAW SRM 51-30-2.SDR CALA9601772Floorbeam · corrodedINSPECTION FOUND FLOORBEAM UPPER T-CAP CORRODED AT STA 328, RBL 10 TO RBL 46. THE UPPER T-CAP WAS REMOVED, A NEW UPPER T-CAP WAS FABRICATED AND INSTALLED IAW SRM 53-10-2 AND 51-30-2.SDR CALA9601771Intercostal · crackedINSPECTION FOUND A 1.5 INCH CRACK IN INTERCOSTAL AT STA 357, STRINGER 16L. A REPAIR DOUBLER WAS FABRICATED AND INSTALLED IAW SRM 51-40-2 AND 51-30-2.SDR CALA9601769Web · corrodedINSPECTION FOUND AFT LAV LT PAN CORRODED AROUND DUMP CHUTE AND CENTER SUBSTRUCTURE CHANNEL CORRODED AT UPPER SURFACE. THE FLOOR WEB AND CENTER CHANNEL WERE REMOVED, A REPLACEMENT WEB AND CHANNEL WERE FABRICATED AND INSTALLED IAW SRM 51-30-2, 51-10-2 AND 51-10SDR CALA9601770Stiffener · corrodedINSPECTION FOUND STA 285.62 NOSE WHEEL WELL RT VERTICAL STIFFENER CORRODED 3 INCHES FROM LOWER END AND 2 INCHES FROM UPPER END. THE VERTICAL STIFFENER WAS REMOVED, A REPLACEMENT STIFFENER WAS FABRICATED AND INSTALLED IAW SRM 51-30-2, 51-10-2 AND BAC DRAWING 6SDR CALA9601842Skin · corrodedINSPECTION FOUND FUSELAGE SKIN CORRODED BETWEEN RIVETS AT BS 964, STRINGER 20L. THE CORRODED AREA OF SKIN WAS CUT OUT, DOUBLERS AND FILLERS WERE FABRICATED AND INSTALLED IAW SRM 53-30-3.SDR CALA9601843Skin · crackedINSPECTION FOUND A 1.75 INCH CRACK IN FUSELAGE SKIN AT BS 775, STRINGER 19R. THE CRACKED AREA WAS CUT OUT, A REPAIR DOUBLER WAS FABRICATED AND INSTALLED IAW SRM 53-30-3.SDR CAL960529Skin · crackedGSO - REMOVED DAMAGE AREA AND FABRICATED DOUBLER, INSTALLED DOUBLER AT STRINGER 20R - STATION 192 PER SRM 53-30-3. (M)SDR CAL960511Switch · inoperativeFLT NR 234 - EWR - RIGHT MAIN LANDING GEAR RED UNSAFE LIGHT ILLUMINATED, AFTER GEAR LOWERED DURING APPROACH FOR LANDING. CYCLED GEAR, RED AND GREEN LIGHT FLICKERED ALTERNATELY DURING SECOND APPROACH. FOUND RIGHT DOWNLOCK SENSOR AT FAULT, REPLACED SAME PER MXSDR CAL951147Skin · corrodedGSO - INSPECTION FOUND THE FUSELAGE SKIN AND DOUBLERS CORRODED AT AFT LOWER CORNER OF C-1 DOORWAY. THE CORROSION WAS REMOVED. REPAIR DOUBLERS WERE FABRICATED AND INSTALLED IAW SRM 51-10-2 AND ECRA 5330-02343. (X)SDR CAL951145Light · inoperativeGSO - INSPECTION FOUND THE LEFT OVERWING INTERIOR EMERGENCY EXIT LIGHT INOPERATIVE. THE EMERGENCY EXIT LIGHT ASSEMBLY WAS REMOVED, RECHARGED, AND INSTALLED. (M)SDR CAL951144Battery Pack · dischargedGSO - INSPECTION FOUND THE OVERHEAD EMERGENCY EXIT LIGHT AT ROW 23 INOPERATIVE. THE EMERGENCY EXIT LIGHT BATTERY PACK WAS REMOVED AND REPLACED. (M)SDR CAL951143Light · inoperativeGSO - INSPECTION FOUND THE L-1 DOOR EMERGENCY EXIT LIGHT INOPERATIVE. THE L-1 DOOR EMERGENCY EXIT LIGHT ASSEMBLY WAS REMOVED AND REPLACED. (M)SDR CAL951142Battery Pack · dischargedGSO - INSPECTION FOUND BOTH RT WING EXTERIOR EMERGENCY LIGHTS INOPERATIVE. THE BATTERY PACK WAS REPLACED AND OPERATION OF THE LIGHTS WAS RESTORED. (M)
Back to N16201, cancelled Nov 16, 1998