FAA incident reports · 1
FAA accident and incident reports matched to this aircraft by N227FR and the event date: up to this one’s cancellation.
Service difficulty reports · 8
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model.
SDR F3LA2021093000071Fan · failedDIVERT IN FLIGHT DUE TO AVIONICS BURNING SMELL . CORRECTIVE ACTION ITEM 1 --- PERFORMED SMOKE INSPECTION IAW TSM 05-50-00-810-831-A . FOUND AVIONICS FAN FAULTED REF LOGPAGE 1276618 ITEM 2 FOR CORRECTIVE ACTION. ITEM 2 DISCREPENCY --- REF LOGPAGE 1276618 ITEM 1SDR F3LA2020120700048Lamp · burned outDISCREPANCY: EPSU SYSTEM IS NOT PASSING. CORRECTIVE ACTION: REMOVED AND REPLACED LT OVERWING DOORS ASSEMBLIES LAMPS. OPERATIONS CHECKED GOOD, REF AMM 33-51-000-720-001-A.SDR F3LA2020111700046Switch · leakingDISCREPANCY: CABIN PR EXCESS RESIDUAL PR. CORRECTIVE ACTION: REF NON ROUTINES NR 122212, 122201 AND 122141. R & R CABIN PRESSURE DETECTION SWITCH (14WN), REFERENCE AMM 52-73-00-720 AND AMM 52-73-12-400-001-A. CORRECTIVE ACTION: REF NON ROUTINES NR 122212, 1SDR F3LA2018120300480Door · unsecureDISCREPANCY: REFERENCE LOG PAGE 1172326 ITEM 1, ATB AT 15252 DUE TO #2 ENG COWL COMING OFF. NOTABLE DAMAGE ON COWL AND ENGINE PARTS
ON POST FLIGHT. COWLING CAME OFF ON DEPARTURE FROM LAS.COMPLIED WITH ALL STEPS OF EA# A2-54R-34518 REV A,
EA# A2-54R-34537 RSDR F3LA2017072700188Battery Pack · no testEPSU 13WL BATTERY FAILED TEST. REMOVED AND REPLACED THE BATTERY PACK. OPS CHECKED OKAY IAW AMM33-51-38 PB 401.SDR F3LA2017061200178Power Supply · no testEPSU SYS TEST FAILED. RESET EPSU (13WL). OPS TESTED NORMAL IAW AMM 23-73-00-740-01.SDR F3LA2016041300033Battery · dischargedREFERENCE LOG PAGE 996831. DURING A SYS TEST THE EPSU 12WL FAILED. R & R BATTERY IAW AMM 33-51-38-000-002A & 33-51-38-400-002A. OPERATION CHECKED GOOD.SDR F3LA2015051801133Pump · failedHYDRAULIC BLUE SYS LOW PRESS. R & R BLUE HYD PUMP. LEAK & OPERATIONAL CHECKED GOOD IAW AMM 29-12-51 PAGE BLOCK 401.