N233TM, cancelled Nov 21, 2005
Service difficulty reports · 81
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N233TM' AND deregistration_id = 'N233TM-2005-11-21' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N233TM' AND deregistration_id = 'N233TM-2005-11-21' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR BJN2002F00000Battery · inoperativeCOCKPIT EMERGENCY LIGHT INOPERATIVE. REMOVE AND REPLACE BATTERIES ON BATTERY PACK PER MM. OPS TEST NORMAL.SDR BJNA020201Power Supply · dischargedFOUND LEFT EXTERIOR OVERWING EMERGENCY LIGHT INOPERATIVE. REPLACED BATTERY POWER SUPPLY IAW BMM 33-51-31, CHECKS NORMAL. (M)SDR BJN2001F00001Light · inoperativeL2 DOOR EMERGENCY EXIT PORTABLE LIGHT INOPERATIVE. REMOVED AND REPLACED PORTABLE EMERGENCY EXIT LIGHT ON L2 DOOR, OPS CHECKED NORMAL.SDR BJNA011107Battery Pack · dischargedLEFT EXTERIOR OVER WING EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED EMERGENCY POWER SUPPLY BATTERY PACK ASSEMBLY. OPS CHECK OKSDR BJNA010902Controller · malfunctionedCABIN RATE OF CLIMB/DESCENT TEMPORARILY INTERMITTENT OPERATION DURING CLIMB IN BOTH 'STANDBY' AND 'MANUAL' MODE. OUTFLOW VALVE WOULD NOT MOVE IN 'MANUAL' MODE. REPLACED OUTFLOW VALVE P/N 763810-2 AND CABIN PRESSURIZATION CONTROLLER P/N 7110033 AS REQUIRED BYSDR BJNA010802Light · inoperativeON WALK AROUND, DISCOVERED LUMINESCENT STRIP ON EMERGENCY TRACK LIGHTING INOPERATIVE. REMOVED AND REPLACED LUMINESCENT STRIP IAW LOETITE LUMINESCENT SYSTEMS, BMM 33-51-01, OPS CHECK GOOD. (M)SDR BJNA010801Light · looseL3 DOOR EMERGENCY EXIT LIGHT INOPERATIVE. REMOVED AND RESEATED L3 DOOR LIGHT ASSEMBLY IAW 33-51-01, OPS CHECK GOOD. (M)SDR BJNA010506Light · damagedAFT CABIN EMERGENCY EXIT TRACK LIGHT DAMAGED BEYOND REPAIR. REMOVED AND REPLACED AFT CABIN EMERGENCY EXIT TRACK LIGHTING, OPS CHECK GOOD IAW 33-51-01. (M)SDR BJNA010505Light · disconnectedFOUND FORWARD FLOOR MOUNTED EMERGENCY EXIT LIGHTS INOPERATIVE. SWAPPED BATTERY PACK WITH CENTER TRACK LIGHTING BATTERY FOUND SERVICEABLE, BUT TRACK NR 1 SECTION FOUND UNHOOKED FROM CIRCUIT. RECONNECTED LIGHTS, OPS CHECK GOOD IAW BMM 33-52-11. (M)SDR BJNA010504Battery · dischargedON WALK AROUND, FOUND OVERWING EXIT EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED BATTERY CARTRIDGE AND POWER UNIT IAW 33-53-00. (M)SDR BJNA010503Battery Pack · dischargedCENTER CABIN EMERGENCY EXIT SIGN LIGHTS INOPERATIVE. REMOVED AND REPLACED LIGHTS BATTERY PACKS 2. OPS CHECK OF EMERGENCY EXIT LIGHTS GOOD IAW BMM 33-51-51. (M)SDR BJNA010303Guard · brokenFOUND EMERGENCY LIGHT SWITCH GUARD SPRING BROKEN. REMOVED AND REPLACED GUARD ON EMERGENCY LIGHT SWITCH P5 PANEL 33-5-01, OPS CHECK NORMAL. (M)SDR BJNA010301Light · inoperativeEMERGENCY FLOOR TRACK FORWARD SECTION INOPERATIVE. CLEANED CONNECTOR ON POWER SUPPLY, OPS TESTED PER LOCTITE LUMINESCENT SYSTEM COMPONENT MANUAL 33-50-01. (M)SDR BJNA010202Smoke Detector · malfunctionedCARGO COMPARTMENT FIRE DETECTION AND SUPPRESSION SYSTEM MESSAFE 1 F12671 ON OVERHEAD CONTROL DISPLAY UNIT. REMOVED AND REPLACED FORWARD SMOKE DETECTOR PER ST 3000 COMPONENT INSTALLATION MANUAL, OPS TESTED SYSTEM NORMAL. (M)SDR BJNA010201Battery · dischargedOVERHEAD MAINTENANCE LIGHT ILLUMINATED FOR LOWER CARGO COMPARTMENT FIRE DETECTION AND SUPPRESSION SYSTEM. AIRCRAFT RELEASED PER MEL 26-19-5-6, ITEM TRANSFERRED TO DMI LOG DMI NR 207, ITEM PLACARDED. REF MEL 26-19-56, DMI 0207, REMOVED AND REPLACED BATTERIES SDR BJNA010103Light · inoperativeFLOOR EMERGENCY LIGHT LAMP INOPERATIVE AT ROW 4 D/E/F. AIRCRAFT RELEASED PER MEL 33-19, ITEM TRANSFERRED TO DMI LOG NR 0127, ITEM PLACARDED. REF MEL 33-19, DMI 0127, REMOVED AND REPLACED LAMP ON FLOOR TRACK PER LUMINESCENT CCM2-5-1. (M)SDR BJNA001105Light · inoperativeAFT OVERHEAD EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED LIGHT ASSEMBLY PER 33-51-91. OPS CHECK NORMAL. (M)SDR BJNA001101Battery Pack · inoperativeEMERGENCY EXIT LIGHT INTERIOR OVERWING EXIT HATCH INOPERATIVE, LEFT AND RIGHT. REPLACED EMERGENCY LIGHT BATTERY PACK POWER SUPPLY, OPS CHECK NORMAL IAW BMM 33-51-31. (M)SDR BJNA000801Battery Pack · inoperativeAFT EMERGENCY TRACK LIGHTS AND REAR DOORS INOPERATIVE. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY PACK. OPS CHECK GOOD IAW BMM 33-51-51. (M)SDR BJNA000701Bleed Valve · contaminatedSMOKE IN CABIN, ALARM SOUNDED. INVESTIGATION DETERMINED LUBE FROM PREVIOUS BLEED VALVE LUBRICATION, TO BE CAUSE OF SMOKE. SEPARATED RT AND LT PACKS WITH BOTH APU BLEED AND ENGINE BLEED SUFFICIENTLY TO CLEAR SYSTEM OF ANY AND ALL RESIDUE. AIR CONDITIONING SYSDR BJNA000413Battery Pack · inoperativeFORWARD EMERGENCY EXIT DOOR LIGHTS INOPERATIVE. REMOVED AND REPLACED BATTERY PACK, OPS CHECK NORMAL IAW 33-51-1. (M)SDR BJNA000414Battery Pack · inoperativeLEFT SIDE OVERWING EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED OVERWING EMERGENCY LIGHT BATTERY PACK, OPS CHECK NORMAL IAW BMM 33-51-31. (M)SDR BJNA000406Light · inoperativeFLOOR EMERGENCY LIGHTS MID SECTION INOPERATIVE. CLEANED CONNECTOR BEHIND SIDEWALL PANEL, OPS TESTED PER LUMINESCENT SYSTEM 33-50-01, PAGE 503, TEST OK. (M)SDR BJNA000204Generator · failedLOST BATTERY CHARGER, NR 1 TANK FUEL BOOST PUMPS BOTH FORWARD AND AFT, LOST NR 1 B-HYD PUMP SYSTEM NR 1 ENGINE THRUST REVERSER CIRCUIT BREAKERS UNABLE TO RESET. RESET CIRCUIT BREAKERS RAN ENGINE, DETERMINED PROBLEM TO BE NR 1 GENERATOR. A/C RELEASED PER MEL SDR BJNA991202Line · chafedAFTER DEPARTING IND, PILOT NOTICED LOW 'A' SYSTEM HYDRAULIC QTY. SOON AFTER LOW PRESSURE OF NR 1 HYD PUMP 'A' SYSTEM MASTER CAUTION WARNING FOLLOWED BY NR 2 HYD PUMP 'A' SYSTEM MASTER CAUTION WARNING.. CREW IMPLEMENTED QHR PROCEDURE AND LANDED AT STL. UPON SDR BJNA110199Connector · contaminatedCENTER SECTION OF EMERGENCY LIGHT WON'T COME ON WITH MASTER SWITCH. CLEANED CONNECTOR MATING ON EL LAMP, TESTED EMERGENCY LIGHT SYSTEM, PER LOCTITE MAINTENANCE MANUAL. OPS TEST OK. (M)SDR BJNA991002Turbine Section · failedFLT 233, A REPOSITION FLIGHT, FROM KTVL TO KSFO, STARTUP, TAXI WERE ACCOMP W/O INCIDENT. AFTER BEING CLEARED FOR T/O, POWER WAS ADVANCED TO T/O EPR OF 2.18. APPROX 2 TO 5 SECONDS AFTER BRAKE RELEASE THE CREW OBSERVED A LOUD BANG COMING FROM THE REAR OF THE ASDR BJNA990603Light · inoperableL2 DOOR EMERGENCY LIGHT INOPERABLE (EXTERIOR). CLEANED LIGHT SOCKET. LIGHT NOW WORKS IAW 33-51-61. (X)SDR BJNA990602Light · inoperableCENTER SECTION OF EMERGENCY FLOOR TRACK LIGHTING INOPERABLE. REMOVED AND REPLACED CENTER SECTION FLOOR TRACK LIGHTING PER LUMINESCENT SYSTEM MANUAL 33-50-01 PAGE 106. (X)SDR BJNA990404Connector · dirtyWITH FLOOR TRACK LIGHTING ON, STANDING AT MID-CABIN, LIGHTS FLICKER. CLEANED AND SECURED CONNECTIONS. OPS CHECK GOOD. (X)SDR 99ZZZX2468Battery Pack · dischargedLEFT OVERWING EMERGENCY EXIT LIGHT INOPERABLE. REMOVED AND RPELACED AFT PIT EMERGENCY BATTEYR PACK PER BMM 33-51-31. OPS CHECK GOOD. (X)