NTSB investigations · 1
Matched to this aircraft by N257PS and the event date: up to this one’s cancellation.
Service difficulty reports · 61
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model.
SDR VNAA202003119995Door Sill · corrodedAFT CARGO DOOR FLOOR SILL CORRODED IN MULTIPLE LOCAITONS FROM FS 574 - 621 UNDER FLOORBOARD 281LLF. 03/02/20 (ROSEM) M/A: 1. N/A. C/A: 1. FOUND AFT CARGO DORO FLOOR SILL TO BE OUT OF LIMITS IAW CRJ 200 53-0-00 SRM. MTC 03/03/20 M/A: 2. REMOVED THE AFT CARGO DOSDR VNAA202003119994Door Sill · corrodedLH PRESSURE FLOOR SILL HAS 3 AREAS OF CORROSION FS449-FS473. 02/20/20 (AS) M/A: 1. N/A C/A: 1. REMOVED CORROSION @ L/H PRESSURE FLOOR SILL BETWEEN FS 409+129 AND FS 559, PRESSURE FLOOR ANGLE 409+128-559 IAW REO 601R-53-41-666, REV.C DATED 2012-11-06. 2/20/20 MSDR VNAA202003119993Door Sill · corrodedRH PRESSURE FLOOR SILL HAS 9 AREAS OF CORROSION BETWEEN FS428 AND FS530. 02/20/20 (AS) M/A: 1. N/A C/A: 1. REMOVED CORROSION @ R/H PRESSURE FLOOR SILL AND FLOOR ANGLE IAW REO 601R-53-41-666, REV.C DATED 2012-11-06. 2/20/20 M/A: 2. REPAIR AREAS REQUIRE NDT TO
See all 61 reports