N288AM, cancelled Jun 20, 2013
Service difficulty reports · 126
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N288AM' AND deregistration_id = 'N288AM-2013-06-20' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N288AM' AND deregistration_id = 'N288AM-2013-06-20' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR TRBA20120830001Cover · missingFLIGHT 4790, CREW REPORTED THE EMERGENCY LIGHT SWITCH COVER AT F/A NR 1 POSITION IS MISSING. ACFT REMOVED FROM SERVICE. REPLACED SWITCH COVER ON EMERGENCY LIGHTING AT F/A NR 1 PANEL 33-50-00. ACFT RETURNED TO SERVICE.SDR TRBA20120710002Fuse · inoperativeTHE CREW REPORTED THE FLOOR EMERGENCY EXIT LIGHT WAS INOPERATIVE. THE ACFT WAS REMOVED FROM SERVICE. REPLACED FUSE AT POWER SUPPLY FIN 61WL PERFORMED OPS CHECK FOUND AND WORKING PROPERLY IAW W/C EX-335000-OPT-10000-01. THE ACFT WAS RETURNED TO SERVICE.SDR TRBA20120530003Cover · missingFLIGHT 4856, THE CREW REPORTED EMERGENCY FLOOR LIGHT ON 12AB MISSING COVER. THE AIRCRAFT WAS REMOVED FROM SERVICE. C/A: INSTALLED EMERGENCY FLOOD LIGHT COVER AT 12AB AREA AS PER JIC 33-51-24. THE OPERATIONAL CHECK WAS GOOD. THE AIRCRAFT WAS RETURNED TO SERVICESDR TRBA20120524002Propeller · out of balanceTHE CREW REPORTED A HEAVY VIBRATION ON RT ENGINE AT 86 PERCENT CLIMB POWER. LT ENGINE VIBRATION TO RT ENGINE OUT OF FEATHER VIBRATES BADLY. THE ACFT WAS REMOVED FROM SERVICE. COMPLIED WITH LT AND RT ON GROUND PROPELLER DYNAMIC BALANCING IAW MM 61-00-00. THESDR TRBA201207201Button · inoperativeTHE CREW REPORTED THE EMERGENCY LIGHT PUSH BUTTON ON F/A PANEL WAS INOPERATIVE. ACFT REMOVED FROM SERVICE. R & R EMERGENCY LIGHT PUSH BUTTON SWITCH IAW STANDARD PRACTICES MM 20-27-17 & AWM 33-51-07. FOUND OK IAW JIC 33-50-00. ACFT RETURNED TO SERVICE.SDR TRBA20120224001Lamp · inoperativeDURING MX INSPECTION, FOUND FLOOR PROXIMITY EMERGENCY ESCAPE PATH MARKNG LIGHT INOPERATIVE. THE ACFT WAS REMOVED FROM SERVICE. R & R FLOOR PROXIMITY EMERGENCY ESCAPE PATH BULB IAW JIC 33-50-00. PERFORMED OPS WAS CHECKED GOOD AS IAW WC EX-335000-OPT-10000-00SDR TRBA2012055001Light · inoperativeDURING PREFLIGHT THE CREW FOUND THE EMERGENCY LIGHT ON 6AB INOPERATIVE.SDR TRBA201205401Control Lever · inoperativeTHE CREW REPORTED THE LANDING GEAR DID NOT GO DOWN WHEN THE LANDING GEAR LEVER WAS MOVED TO THE DOWN POSITION, HAD TO USE THE EMERGENCY EXTENSION HANDLE. R & R LANDING GEAR CONTROL LEVEL IAW JIC 32-31-81. PERFORMED NORMAL EXTENSION & RETRACTION FUNCTIONAL TESSDR TRBA2012052001Contactor · failedTHE CREW REPORTED THE EMERGENCY BATTERY CHARGER FAULT LIGHT ON. THE ACFT WAS REMOVED FROM SERVICE. R & R EMERGENCY BATTERY CHARGER CONTACTOR 42PA IAW JIC 24-00-00-RAI-10010 AND FIG 24-00-00-RAI-00122 . THE OPS TEST IAW JIC 24-50-00-OPT-10000 FOUND OK. THE ASDR TRBA2012047001Bulb · burned outDURING B-INSPECTION, FOUND THE EMERGENCY LIGHT 6AB BURNED OUT. THE ACFT WAS REMOVED FROM SERVICE. COMPLIED WITH REMOVAL AND INSTALLATION OF FLOOR EMERGENCY LIGHT BULB AT SEAT 6AB IAW EX 335000-OPT-10000-001. THE OPS CHECK WAS GOOD. THE ACFT WAS RETURNED TOSDR TRBA2012030003Light · brokenTHE CREW REPORTED THE EMERGENCY EXIT LIGHT TRIM BROKEN AT ROW 17. THE ACFT WAS REMOVED FROM SERVICE. EMERGENCY LIGHT COVER JUST CAME OFF-NOT BROKEN. RESECURE LIGHT COVER IN REF TO JIC 33-51-21. THE ACFT WAS RETURNED TO SERVICE.SDR TRBA2012010002Light · damagedEMERGENCY FLOOR LIGHT COMING APART AROUND ROWS 15 AND 16. THE ACFT WAS REMOVED FROM SERVICE. RESECURED EMERGENCY LIGHT STRIP AT ROWS 15 AND 16 IAW JIC 33-50-00. THE ACFT WAS RETURNED TO SERVICE.SDR 2011FA0000789Dome · crackedOIL LEAK FROM CRACK AT FRONT BORE OF ACTUATOR DOME, FOUND DURING PERFORMANCE RUNS.SDR TRBA201134301Bulb · looseGROUND FLOOR LIGHT NEAR SERVICE DOOR IS INOPERATIVE. F/A FOUND LIGHT INOPERATIVE ON WALK AROUND RESET LIGHT BULB , OPS CHECKED GOOD REF AMM 33-51-24.SDR TRBA201134201Roller · dirtyMAIN CABIN DOOR VERY HARD TO OPEN. CLEAN ROLLER ON UPPER LT SIDE OF PAX DOOR AND PERFORMED FUNCTIONAL CHECK GOOD IAW 52-11-00.SDR TRBA201134302Bulb · inoperativeGROUND FLOOR LIGHT ON MAIN CABIN DOOR IS INOPERATIVE. F/O FOUND LIGHT INOPERATIVE ON WALK AROUND RESET LIGHT BULB, OPS CHECKED GOOD REF AMM 33-51-24.SDR TRBA201125801Lamp · inoperativeEMERGENCY LIGHT CABIN DOOR INOPERATIVE. RELAMPED LIGHT ON CABIN DOOR IAW JIC 33-40-00.SDR TRBA201124202Wire · damagedTHE AGENT 2 DISCHARGE LIGHT IS ILUMINATED ON FIRE DETECTION SYS 1 AND AGENT 1 IS ON SYS 2. OPS CHECKED SYS GOOD REPAIRED WIRES IAW AMM SPM 20-41-00 AND OPS CHECKED GOOD IAW AMM 26-12-00, OPT 10000.SDR TRBAWarning Light · malfunctionedTHE AGENT 2 DISCHARGE LIGHT IS ILUMINATED ON FIRE DETECTION 1 AND AGENT 1 IS ON SYS 2. OPS CHECKED SYS GOOD REF AMM 26-12-00, OPT 10000.SDR TRBA201123105Socket · dirtyEMERGENCY LIGHT AT BOTTOM OF PAX DOOR BLINKS INTERMITTENTLY. CLEANED CONTACT ON EMERGENCY LIGHT SOCKET IN ENTRANCE STAIRS. OPS CHECK GOOD.SDR TRBA2011084Lamp · burned outTHE CREW REPORTED THE EMERGENCY EXIT LIGHT AT THE BOTTOM OF THE CABIN DOOR TO BE INOPERABLE. THE ACFT WAS REMOVED FROM SERVICE. RELAMPED IAW MM 33-50. THE OPS CHECK WAS GOOD. THE ACFT WAS RETURNED TO SERVICE.SDR TRBA2011058Connector · brokenEMERGENCY EXIT LIGHT ON STAIRS INOPERATIVE. RESECURED PINS AT TERMINAL CONNECTOR FIN NR 253VC IAW 33-51-11. OPS CHECK OK.SDR TRBA2011005Bulb · inoperativeEMERGENCY LIGHT (BOTTOM STEP LIGHT ) ON CABIN DOOR, INOP. REPOSITIONED MAIN DOOR EMERG LIGHT BULB AND OPT CK GOOD IAW W/C EX-33-50-00 OPT-001.SDR TRBA2011003Light · no testCABIN DOOR EMERGENCY LIGHT WON'T TEST. R & R OF EMERGENCY GROUND ILLUMINATION FLOOD LIGHT ASSY 21WL IAW AMM JIC 33-51-24 AND W/C OPT SATISFACTORY IAW EX-335000OPT10000-001.SDR TRBA2011002Wire · damagedEMERGENCY LIGHT AT BOTTOM OF STAIRS ON MAIN CABIN DOOR INOP. REPAIRED WIRE BY DOOR UPPER STEP IAW STD PRACTICE, OPT CK GOOD IAW MM 33 50 00.SDR TRBA2010147Engine · failedNR 1 ENGINE FAILURE DURING DESCENT WITH IMMEDIATE RELIGHT. PERFORMED SPECIAL REQUEST 288720348, ISPECTED LT ENGINE WIRING, NO DEFECTS NOTED. REMOVED AND REPLACED AFU IAW ATR 72 JIC 77-13-62 OPS CHECK NORMAL. INSPECTED AND CLEANED TORQUE SENSORS CONNECTOR, NOSDR TRBA2010120Wire · damagedPASSENGER STAIR EMERGENCY LIGHT BURNED OUT. REPAIRED WIRE AT MAIN DOOR CONNECTOR IAW STD PRACTICE ,OPT CK GOOD IAW MM 52 70 00.SDR TRBACPCP2010050Bulkhead · corrodedDURING SCHEDULED HEAVY CHECK INSP, CORROSION WAS FOUND ON THE FWD PRESSURE IN 1 AREA OF THE BULKHEAD WEB. COMPLIED WITH EO E2-53MR-260 ON FRAME 1 FWD PRESSURE BULKHEAD WEB CORROSION BLEND OUT REPAIR, REF NDT REPORT AMS 100907-27 FOR HFEC & UT VALVES NO DEFECSDR TRBA2010104Socket · burnedAFTER TAKEOFF STRONG ELECTRIC ODOR IN COCKPIT POSSIBLY UNDER PANEL BEHIND F/O SEAT, F/A'S CABIN HAS NO SMELL. IAW JIC 33-21-23, REPLACED FLORESCENT TUBS SOCKET LIGHT ASSY FIN 286LGA. OPS CHECK OK AWM USED 61-22-01 FOR WIRE CONNECTION.SDR TRBA2010042Bulb · inoperativeEMERGENCY LIGHT MAIN ENTRY STAIRS INOP. ADJUSTED BULB OF MAIN DOOR AND PERFORMED OPT IAW JIC 33-50-00.SDR TRBA2010035SUPO-Ring · leakingDURING CLIMB OUT WHEN SELECTING BLEED VALVE ON IN THE COCKPIT WE GET A NOXIOUS DIRTY SOCK EXHAUST SMELL. SMELL GOES AWAY WHEN DESELECTING NR 1 BLEED VALVE. R & R LT ENG NR 5, 6, 7 SCAVENGE TUBES O-RINGS IAW MM 72-01-50. NO SMELL NOTED AT THIS TIME, NO LEAKS.SDR TRBA2010035O-Ring · leakingDURING CLIMB OUT WHEN SELECTING BLEED VALVES ON , IN THE COCKPIT WE GET A NOXIOUS DIRTY SOCK EXHAUST SMELL, SMELL GOES AWAY WHEN DESELECTING NR 1 BLEED VALVE. R& R LT ENG NR 5, 6 AND 7 SCAVENGE TUBE O-RINGS IAW MM 72-01-50, NO SMELL NOTED AT THIS TIME, NO LEASDR TRBA2010020SUPEngine · malfunctionedON APPROACH RT ENGINE TQ AND NP WENT TO 0 PERCENT, NH AND ITT STILL SHOWED 76 PERCENT AND 400 PERCENT, PLANE YAWED SHARPLY DURING EVENT. PERFORMED ENGINE GROUND OPS CHECK IAW EX-055007-CS-20000-001 AND FOUND WORKING OK, CANNOT DUPLICATE PROBLEM ON GROUND. TACSDR TRBA2010013SUPBleed Valve · inoperativeAFTER BLEEDS ON DURING CLIMB, A STRONG ACIDIC ODOR FILLED THE COCKPIT AND THEN SLOWLY GOT BETTER ENROUTE. BOTH COCKPIT CREW EXPERIENCED FEELING OF LIGHTHEADEDNESS, TINGLING LIPS & FINGERS, BY THE TIME WE STARTED OUR DESCENT, AFTER TOUCHDOM THE SAME STRONG SMELSDR TRBA2010013Unknown · odorAFTER BLEEDS ON DURING CLIMB, A STRONG ACIDIC ODOR FILLED THE COCKPIT AND THEN SLOWLY GOT BETTER ENROUTE. BOTH COCKPIT CREW EXPERIENCED THE FEELING OF LIGHT HEADEDNESS, TINGLING LIPS & FINGERS BY THE TIME WE STARTED OUR DESCENT, AFTER TOUCHDOWN THE SAME STRONSDR TRBA2010012SUPValve · odorSTRONG ODOR COMING FROM BOTH PACKS ON CLIMB AFTER BLEEDS SELECTED ON. (SEE TURNOVER). ADDED SPACERS ON AIR SWITCHING VALVE, LT ENGINE MFG TROUBLESHOOT MANUAL 72-00-01. FAULT ISOLATION FIG 108, OPS CHECK FOUND WORKING PROPERLY FOR MORE INFO NRWC 245019, TAC 36SDR TRBA2010012Unknown · odorSTRONG ODOR COMING FROM BOTH PACKS ON CLIMB AFTER BLEEDS SELECTED ON. AWAITING AML PAGE FOR FURTHER DETAILS.SDR TRBA20100009SUPSeal · leakingLT PACK INOP, UNABLE TO BRING DUCT TEMP BELOW 40 DEGREES C, DURING T-OFF & CLIMB, STRONG BURNED OIL SPELL ACCOMPANIED BY TOO WARM TEMP. RETURNED TO DEPARTURE. R & R LT AIR CYCLE MACHINE CLAMP IAW MM 21-11-51 AND PERFORMED OPS CHECK AND FOUND WORKING PROPERLYSDR TRBA2010009Clamp · failedLT PACK INOP, UNABLE TO BRING DUCT TEMP BELOW 40 DEGREES C, DURING T-OFF & CLIMB, STRONG BURNED OIL ODOR ACCOMPANIED BY TOO WARM TEMP. RETURNED TO DEPARTURE. R & R LT AIR CYCLE MACHINE CLAMP IAW MM 21-11-51 AND PERFORMED OPS CHECK AND FOUND WORKING PROPERLY ATSDR TRBA2009112Wire · disconnectedACFT DURING TAKEOFF FROM EIS AT ABOUT 1000 TO 1500 FT, HAD AN UNANNOUNCED PITCH DISCONNECT. NO INDICATION ON THE CAP. EMERGENCY DECLARED. LANDED REPAIRED WIRE AT CONNECTOR FIN NR 171WWA IAW ASM NR31-53-00 SCH 06 P111 FIG 1. ALSO RECONNECT PITCH MECHANISM ASDR TRBA2009058Lamp · failedRIGHT REAR OUTSIDE EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED LAMP AND PERFORMED OPERATIONAL CHECK IAW JIC NR 33-51-00.SDR TRBA2009057Lamp · failedMAIN PAX DOOR STAIR LIGHT INOPERATIVE. REMOVED AND REPLACED LAMP AND PERFORMED OPERATIONAL CHECK IAW JIC NR 33-51-00.SDR TRBA2009048SUPEngine · failedENGINE OIL ALERT RECEIVED FOR ENGINE 32. BOTH CAP ALERT AND WARNING LIGHT ON INDICATOR. OIL PRESSURE FOR NR 2 ENGINE ZERO. RETURNED TO MIA WITH 32 ENGINE SHUT DOWN. REMOVED AND REPLACED NR 2 ENGINE IAW W/C 055006-CS-20000-001 AND 72 JIC NR 72-00-00-RAI-10SDR TRBA2009048Engine · failedENGINE OIL ALERT RECEIVED FOR ENGINE NR 2. BOTH CAP ALERT AND WARNING LIGHT ON INDICATOR. OIL PRESSURE FOR NR 2 ENGINE ZERO. RETURNED TO MIA WITH NR 2 ENGINE SHUT DOWN. REMOVAL OF NR 2 ENGINE IN PROGRESS. AWAITING AML FOR FURTHER DETAILS.SDR TRBA2009027Lever · failedLANDING GEAR HANDLE WILL NOT MOVE TO RETRACT GEAR POSITION (AT SDQ). DEFERRED LANDING GEAR RETRACTION SYSTEM AS PER MEL 332-03 AUTH NR 020233DM-C. MEL CLEARED ON 02-26-09 AT SJU, REPLACED LANDING GEAR CONTROL LEVER AS PER JIC NR 32-31-81.SDR TRBA2009003Light · out of positionPAX DOOR EMERGENCY LIGHT INOPERATIVE. REPOSITIONED LAMP ON PAX DOOR EMERGENCY LIGHT ASSY AND PERFORMED OPT CK IAW MM NR31-51-24.SDR TRBA2009001Light · out of positionEMERGENCY LIGHT NEXT TO SERVICE DOOR INOPERATIVE. REPOSITIONED LAMP AT EMERGENCY LIGHT NEXT TO SERVICE DOOR AND PERFORMED OPS CHECK IAW MM NR 35-51-24.SDR TRBA2007097Light · burned outPASSENGER ENTRY STAIRS EMERGENCY LIGHT OUT. REMOVED AND REPLACED PAX/CREW DOOR EMERGENCY LIGHT IAW JIC 33-51-25. PERFORMED OPT CHK FOUND WORKING PROPERLY AT THIS TIME.SDR TRBA2007086Wire · brokenONE OF THE EMERGENCY EXIT LIGHTS IN THE STAIRS IS BURNED OUT. REPAIRED BROKEN WIRE AT PASSENGER CREW DOOR IAW SRM 20-24-17. PERFORMED OPT CHK IAW JIC 33-50-00 AND FOUND WORKING PROPERLY AT THIS TIME.SDR TRBA2007076Wire · brokenEMERGENCY EXIT LIGHT ROW 6 INOPERATIVE. REPAIRED BROKEN WIRE ON EMERGENCY LIGHT ROW 6. PERFORMED OPERATIONAL CHECK AND FOUND WORKING PROPERLY PER MM 33-50-00.
Back to N288AM, cancelled Jun 20, 2013