N304WA, cancelled Sep 2, 2005
Service difficulty reports · 24
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N304WA' AND deregistration_id = 'N304WA-2005-09-02' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N304WA' AND deregistration_id = 'N304WA-2005-09-02' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DL733050197Fire Loop · faultyAPU FIRE WARNING LIGHT/ALARM BELL IN FLIGHT APPROX 1 TO 2 MINS AFTER APU SHUTDOWN IN FLIGHT AT 10 TO 12,000 FT ALT FIRE BOTTLE USED. REMOVED APU SHROUD, APU INSPECTED FOUND NO EVIDENCE OF FIRE. REPLACED AFT DETECTOR LOOP.SDR DL733040960Skin · dentedFUSELAGE SKIN DENTED AT STA 827 BETWEEN STR 26R - 28R. REPAIRED IAW ERA 093986-14.SDR DL733030162Hose · leakingON ARRIVAL DEN FOUND FUEL LEAKING FROM RT ENGINE. INSP FOUND MAIN FUEL LINE FROM PYLON TO ENG FUEL PUMP LEAKING AT SWEDGED END / PYLON SIDE. REPLACED SAME.SDR DL733030151Fire Loop · unserviceableDURING PUSHBACK APU FIRE WARNING CAME ON APU SHUTDOWN AND INDICATION EXTINGUISHED APPROXIMATELY 2 MINUTES LATER. FIRE INDICATION RETURNED AND REMAINED ON. CREW FIRED APU EXTINGUISHER BOTTLE AND FIRE LIGHT DID NOT GO OUT. INSPECTED APU AND COMPARTMENT AREA NSDR DL733030144Control Module · failedAT 8000 FT APU FIRE LIGHT AND BELL SOUNDED, C/W PROC LIGHT STILL ON. AIR TURNBACK TO OAK. REPLACED FIRE DETECTOR CONTROL MODULE.SDR DL733021260Spar · corrodedDURING OVERHAUL THE NR 1 MID-FLAP WAS FOUND WITH CORROSION IN THE REAR SPAR LOWER CHORD. REPAIR PER ER/A 417872-14.SDR DL733020391Beam · corrodedCORROSION WAS FOUND ON THE CROWN BEAM LUG BORES ON THE #1 AND #2 PYLONS. THE BORES WERE OVERSIZED TO REMOVE THE CORROSION AND REPAIR BUSHINGS WERE INSTALLED. THE DAMAGE WAS FOUND AT HMV.SDR DL733020358Skin · delaminatedUPPER SKIN OF THE OUTBOARD SPOILER WAS FOUND DELAMINATED IN TWO AREAS. REPAIR PER ER/A 411104-14 NORDAM EWO E0037119 REV I/R.SDR DL733011010Skin · damagedTHE FUSELAGE BELLY SKIN WAS GOUGED, DENTED AND PUNCTURED AT SEVERAL LOCATIONS BETWEEN FS 400 & 470 AND BETWEEN STRINGERS 26L & 26R.SDR DL733010925Web · crackedDURING INSPECTION PER SB 737-53A1173 REVISION 3, FOUND COCKPIT FLOOR WEBS JUST AFT OF 178 BULKHEAD CRACKED.SDR DL733010527Attach Fitting · brokenDURING GEAR EXTENSION THE NOSEGEAR DID NOT EXTEND. THE VALVES COULD BE HEARD SHIFTING BUT THE NOSEGEAR REMAINED UP. THE GEAR WAS CYCLED 3 TIMES WITHOUT MOVING THE NOSE GEAR. THE MLG OPERATED NORMALLY. FOLLOWED POM PROCEDURES ON THE 4TH ATTEMPT THE NOSEGEASDR DL733010352Circuit Breaker · malfunctionedAT TOP OF DESCENT ALL COCKPIT INSTRUMENTS AND INDICATORS EXPERIENCED A MOMENTARY LOSS OF POWER - ON ENGINE GENERATORS, VISUAL CONDITIONS. POWER WAS RESTORED IMMEDIATELY WITH NO CREW ACTION. REMAINDER OF FLIGHT NORMAL. REPLACED NR 2 GENERATOR BREAKER.SDR DL733010066Coalescer Bag · odorBIRD STRIKE NR 2 ENGINE IN CLIMBOUT. HIT BIRD AT ABOUT 500 FT AGL. ENGINE PARAMETERS NORMAL, BAD ODOR IN AIRCRAFT. PERFORMED BIRD STRIKE INSPECTION PER MM PROCEDURES. FOUND EVIDENCE OF BIRD STRIKE NR 2 ENGINE. NO DAMAGE NOTED. REPLACED COALESCER BAG RT PSDR DL733992712Wire · brokenFIRST CLASS LAV SMOKE DETECTOR INOP. REPLACED BROKEN WIRES AT SWITCH DETECTOR.SDR DL733992377Pcu · failedAT FL370, MACH .76 THE ACFT EXPERIENCED AN UNCOMMANDED YAW, (TWO SEPARATE SHARP INPUTS). YAW DAMPER SWITCH TURNED OFF. MTC IN PROGRESS REPLACING RUDDER PCU, YAW DAMP COUPLER AND WIRING CHECKOUT.SDR DL733992223Unknown · odorPAX AT 2C SMELLED SLIGHT ODOR IN CABIN, F/O REPORTED A FAINT ODOR, BUT COULD NOT RECOGNIZE WHAT TYPE. RECIRCULATION FAN AND CABIN BALLAST LIGHT TURNED OFF. NR 2 TR C/B POPPED, DID NOT RESET DUE TO PREVIOUS WRITE-UP. ON PREVIOUS FLT 1450 IAH, REPLACED NR 2 SDR DL733992129Switch · out of adjustDURING FLAP EXTENSION HAD L/E INTRANSIT LIGHT FOR NR 4 SLAT AND L/E FLAPS/SLAT INTRANSIT LIGHT ON FWD PANEL. WITH FLAPS AT 15 DEG THERE WAS AN INCREASE IN AIR NOISE, LEVEL AND A/C YAWED. EMERGENCY DECLARED, FLAPS RECYCLED INDICATION REOCCURED BUT NO YAW. FSDR DL733990219Overheat Light · illuminatedON APPROACH COS, NR 1 ENGINE OVERHEAT LIGHT ILLUMINATED. CREW DISCHARGED BOTH BOTTLES, LIGHT REMAINED ILLUMINATED EVEN AFTER ENGINE SHUTDOWN. PARTS ARRIVING FROM SLC AND DFW. REPLACED BOTH FIRE BOTTLES, FIRE TEST MODULE AND LOWER LOOP.SDR DL733982638Line · leakingAIR TURNBACK DUE TO ELECTRICAL SMELL IN CABIN. MTC TROUBLESHOT AND FOUND THE LEFT PACK WAS OVERHEATING. ITEM THEN FWD TO MCO. FOUND HYDRAULIC LINE LEAK. TIGHTENED NUT AND CLEANED AREA.SDR DL733980536Battery Charger · damagedNORMAL BLOWER POPPED CIRCUIT BREAKER. LEFT PACK TRIP TWICE. NR 1 GENERATOR VOLT/FREQUENCY ZERO. ELECTRICAL SMELL IN CABIN. FOUND BATTERY CHARGER BURNT. REPLACED BATTERY CHARGER.SDR DL733972502Prox Sensor · failedUNABLE TO RETRACT GEAR. REPLACED PROX SENSORS ON NOSE GEAR AND RT MLG, PERFORMED GEAR SWING.SDR DL733970580Smoke Detector · failedFWD LAV SMOKE BELL WARNING AFTER PUSH OUT. REPLACED FWD LAV SMOKE DET.SDR DL733954404Frame · crackedTHE C-1 DOOR, LWR AFT FRAME HAS A 2.5 INCH LONG CRACK IN THE OUTBOARD RADIUS BELOW STOP NUMBER 4 AND OUTBOARD OF THE LOWER TORQUE TUBE. THE LOWER FWD FRAME HAS A 0.75 INCH CRACK ON THE INBOARD RADIUS JUST ABOVE STOP NUMBER 5. THIS ER/A INSTALLS A STEEL REPAISDR DL733954375Eel Power Supply · dischargedBOTH OVERWING EMERGENCY LIGHTS INOP. REPLACED POWER SUPPLY, OPERATION NORMAL.
Back to N304WA, cancelled Sep 2, 2005