N308TZ, cancelled Aug 5, 2008
Service difficulty reports · 43
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N308TZ' AND deregistration_id = 'N308TZ-2008-08-05' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N308TZ' AND deregistration_id = 'N308TZ-2008-08-05' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2008FA0000401Skin · dentedDURING SCHEDULED INSPECTION, FOUND DENT IN LT L/E OF HORIZ STAB STA 105. S/O 245008, N/R 21591. S/O 245008, N/R 21591. (K)SDR 2008FA0000400Skin · dented(REF DU4R2008227) DURING SCHEDULED INSPECTION, FOUND OUT OF LIMITS DENT IN LT HORIZ STAB L/E STA 280. S/O 245008, N/R 21578 (K)SDR AMTA200800048Battery · dischargedFLASHLIGHT UNDER REAR FLIGHT ATTENDANT JUMPSEAT AIRCRAFT LT RED LIGHT DOES NOT BLINK. REMOVED AND REPLACED FLASHLIGHT BATTERY IAW MM 25-64-00. OPS CHECKED GOOD. (K)SDR AMTA200700717Hmu · unserviceableENGINE CONTROL LIGHT, LIGHT ON, ENGINE NR 2. REMOVED AND REPLACED NR 2 ENGINE HYDROMECHANICAL UNIT IAW MM 73-21-10-4. OPS CHECK NORMAL. OK FOR SERVICE. (K)SDR AMTA200700713Warning Light · false indicationENGINE CONTROL LIGHT, LIGHT ON ENGINE NR 2. PERFORMED ACTUATOR TEST IAW AMM 71-00-00-5. NO FAULTS NOTED, OK FOR SERVICE. (K)SDR AMTA200700591Sensor · unserviceableLT BLEED TRIP OFF LIGHT ON, LT ENG IS THE BLEED SOURCE. REMOVED AND REPLACED PRE-COOLER CONTROL VALVE SENSOR IAW AMM 36-12-03-4. OPS CHECK NORMAL. (K)SDR AMTA200700573Skin · nickedRT WING IB AFT FLAP LOWER SURFACE HAS MULTIPLE NICKS AND DINGS IN MLG TIRE PATHWAYS. REPAIRED IAW SAA EA 737-5753-09-A1149 AND SRM 57-53-02-DI REF ATA ERA 737-57R-6170 FOR REPETITIVE REINSPECTION EVERY B3500, FLT CYCLES OR 24 MONTHS CLASS MAJOR. (K)SDR AMTA200700527Computer · unserviceableLT FMC FAILED. REMOVED AND REPLACED LT FMC IAW REF AMM 34-61-02-4. PERFORMED OPERATIONAL TEST IAW REF AMM 34-61-00-5. OPS CHECK GOOD. (K)SDR AMTA200700508Sensor · unserviceableLT ALPHA VANE LT ILLUM IN FLIGHT WILL NOT EXTINGUISH. REMOVED AND REPLACED AOA VANE IAW 34-21-05-4. OPS CHECK GOOD. (K)SDR AMTA200700507Processor · unserviceableNO FUEL QUANTITY INDICATION ON FMC. REMOVED AND REPLACED FQIS PROCESSOR IAW AMM 28-41-81-4.SDR AMTA200700503Skin · damagedLT WING AFT FLAP LOWER SURFACE HAS MULTIPLE DENTS AND DINGS. REPAIRED IAW SAA EA 737-5753-09-A1150, INTERM REPAIR REINSPECT EVERY 3500 FLIGHT HOURS OR 24 MONTHS WHICHEVER COMES FIRST IAW ATA ERA 737-57R-6171. (K)SDR AMTA200700502Skin · damagedRT WING IB AFT FLAP LOWER SURFACE HAS MULTIPLE NICKS AND GOUGES IN MLG TIRE PATHWAYS. REPAIRED IAW SAA EA 737-5753-09-A1150 INTERM REPAIR REINSPECT EVERY 3500, FLIGHT CYCLES OR 24 MONTHS WHICHEVER COMES FIRST IAW ATA ERA 737-57R-6170 1405-523. (K)SDR AMTA200700501Attach Fitting · damagedUPON INNSPECTION OF FORWARD SPAR ATTACHMENT BOLTS FOUND THE RT LOWER AND RT UPPER BOLTS DEFECTIVE, GALLING AND FRETTING WEAR. COMPLIED WITH EO 737-55AD-2935, REPLACED (2) BOLTS WITH PN 180A1611-3. (K)SDR AMTA200700500Floor Panel · corrodedAFT CARGO PNL 140BF STRAP HAS CORROSION ON LWR SURFACE STA 727D, LBL 25 - RBL 25. FABRICATED TEE STRAP IAW SRM 53-42-11-26. REPLACED TEE STRAP IAW 51-40-02. (K)SDR AMTA200700498Floor Panel · corrodedAFT CARGO PNL 140AF HAS CORROSION AROUND EDGES UPPER SURFACE STA 727+4 - 727D, LBL 25- 25 RBL. FABRICATED AFT CARGO FLOOR PNL 140AF ALODINED AND PRIMED, IAW SRM 53-60-53-0I, SRM 51-20-01-0G. (K)SDR AMTA200700497Floor Panel · corrodedAFT CARGO FLOOR PANEL 140CF HAS CORROSION AROUND EDGES OF UPPER SURFACE. FABRICATED AFT CARGO FLOOR PANEL 140CF ALODINED AND PRIMED IAW SRM 53-60-53, SRM 51-20-01-06. (K)SDR AMTA200700496Floor Panel · corrodedAFT CARGO FLOOR PANEL 140DF, (AFT) HAS CORROSION AROUND EDGES OF UPPER SURFACE STA 887- 947, LBL 14- RBL 25. FABRICATED NEW FLOOR PANEL IAW SRM 53-70-54-01 (2024 T-3 .071) ALODINED AND PRIMED IAW SRM 51-20-01. (K)SDR AMTA200700495Floor Panel · corrodedFWD CARGO FLOOR PANEL 120DF HAS CORROSION AROUND EDGES. UPPER SURFACE STA 500D-540, LBL 25- RBL 25. FABRICATED AFT CARGO FLOOR PANEL 120DF, ALODINED AND PRIMED, IAW 53-30-53-0I, SRM 51-20-01. (K)SDR AMTA200700494Floor Panel · corrodedFWD CARGO FLOOR PANEL 120BF HAS CORROSION ON EDGE OF UPPER SURFACE AS MARKED STA 440-500, LBL25-RBL 20. FABRICATED FLOOR PANEL 120BF, MAT`L 2024-T3, .071, IAW SRM 53-30-53-01, SRM 51-20-01-0E. (K)SDR AMTA200700278Unknown · unknownAPU AUTO SHUTDOWN. NO FAULT LIGHT ILLUMINATED. MSG FCU DISAGREE WITH COMMAND 49-31171 FAULT CLEARED AFTER APU RESTART. FOUND FUEL QUANTITY LOW. (K)SDR AMTA200700277Cdu · failedRT FMS CDU BLANK. REPLACED CDU IAW AMM 34-61-01-2. (K)SDR AMTA200700281Fmc · inoperativeSINGEL FMC OPERATION MESSAGE SHOWS ON THE CDU (NR2 FMC INOPERATIVE). (K)SDR AMTA200700275Fmc · inoperativeNR 2 FMS INOPERATIVE, OK WHEN SWITCHED TO BOTH ON LT. REMOVED AND REPLACED FMS COMUTER IAW AMM 34-61-02-4. NR 2 FMC SYSTEM OPS NORMAL. ALL SOFTWARE VERIFIED CORRECT. (K)SDR AMTA200700272Fmc · malfunctionedRT FMC FAIL, SINGLE FMC OPERATION NORMAL WITH FMC SELECTOR IN BOTH ON LT. UNABLE TO DUPLICATE FAULT. PERFORMED BITE IAW FIM 34-61-00-810-801, NO FAULTS NOTED. FMC OPS NORMAL. (K)SDR AMTA200700264Warning System · malfunctionedPSEU LIGHT ILLUMINATED ON RECALL LIGHT EXTINGUISHES ON MASTER CAUTION RESET. PERFORMED FIM TEST IAW 32-09-00-810-801, NO DEFECTS NOTED. OK FOR SERVICE. (K)SDR AMTA200700108Pseu · malfunctionedPSEU LIGHT ILLUMINATED ON RECALL DURING TAXI IN. PERFORMED PSEU BITE IAW FIM 32-09-00-810-801 FAULT CODES 27-62004 AND 32-62006, AND FIM 32-61-00-810-806 AND 823. FOR R/RADIO ALTIMETER, CLEARED FAULTS AND PERFORMED BITE ON PSEU AND RAD-ALT NO FAULTS NOTED. SDR AMTA200700078Warning Light · illuminatedRT PACK LIGHT ILLUMINATED DURING RECALL RESET WITH MASTER CAUTION RESET. (K)SDR AMTA200700047Detector · unserviceableNR 2 ENGINE OVERHEAT DET WILL NOT TEST IN A MODE. WORKS OK IN B. REMOVED AND REPLACED NR 2 ENG UPPER FAN FIRE DETECTOR IWA AMM 26-11-01-4 SYSTEM TESTS NORMAL, NO FAULTS. (M)SDR AMTA200600540Sensor · malfunctionedLEFT AND RIGHT DUCT PRESSURE SPLIT AT CRUISE ALT L WAS 44 PSI AND R IS 28 PSI. REMOVED AND REPLACED OF 390 DEG SENSOR, AND SWAP OF BAR`S, RAN ENGINES AT 80 PERCENT N1 FOR 15 MINUTES, PACKS ON, LT ENGINE PRESS 43 PSI R ENGINE PRESS 38 PSI, IN LIMITS PER FIM 36SDR AMTA200600539Shutoff Valve · malfunctionedLEFT AND RIGHT DUCT PRESSURE SPLIT R-DUCT PRESSURE 10-15 PSI LOWER THAN L DUCT AT CRUISE. REMOVED AND REPLACED PRSOV, AND HP REGULATOR. PERFORMED BLEED AIR CHECK PER FIM 36-10-00-810-804, L/R BLEED PRESS`S MATCH AT ALL TESTED N1 SPEEDS. (M)SDR AMTA200600451Warning Light · illuminatedNR 2 ENGINE (ENGINE CONTROL LIGHT ON AFTER LANDING). PERFORMED FIM, ENG CONTROL LIGHT, FOUND RT AND LT SLEEVE SYNC SENSOR STOW SENSOR AND LOCK SENSOR LIGHT ON THE EAU BOX, RESET BOX, OPERATED T/R, S OPS CHECKED OK, NO FAULTS ON BOX, OK TO CONTINUE. (K)SDR AMTA200600351Warning Light · illuminatedDURING CLIMB LT BLEED TRIP OFF LIGHT ILLUMINATED. IAW FIM 36-10-00-810-801, STEP I, PERFORMED REPAIR CONFIRMATION, ALL INDICATIONS WERE SATISFACTORY, OK FOR SVC. (K)SDR AMTA200600356Warning Light · illuminatedDURING CLIMB OUT LT PACK BLEED TRIP OFF LIGHT ILLUMINATED. IAW FIM 36-10-00-810-801 PERFORMED REPAIR CONFIRMATION. ALL INDICATIONS NORMAL, (BLEED TRIP OFF), LIGHT DID NOT ILLUMINATE, OK FOR SERVICE. (K)SDR AMTA200600350Regulator · unserviceableDURING CLIMB LT BLEED TRIP OFF LIGHT ILLUMINATED. REMOVED AND REPLACED HIGH STAGE REGULATOR IAW. OPS AND LEAK CHECK GOOD. (K)SDR AMTA200600341Hydraulic System · underservicedFLAPS WOULD NOT MOVE BEYOND 25 DEG WHEN SELECTED TO 30 DEG NOTE (B) SYSTEM QUANTITY INDICATES 70 PERCENT RF. SERVICED (B) SYS HYD, PERFORMED OPS CHECK OF THE TE. OPS CHECK NORMAL, REF MM. (K)SDR AMTA200600338Fire Loop · contaminatedFIRE/OVERHEAT DETECTION TEST ENGINE NR 2 FAILED IN LOOP A. PERFORMED BITE TEST ON ENG/APU FIRE DETECTION CONTROL MODULE. CLEANED FIRE LOOP A CONTACT POINTS OPS GO OD, IAW 26-10-00-810-801 OK FOR CONT SERVICE. (K)SDR AMTA200400379Floor Panel · corrodedCORROSION: AFT CARGO COMPARTMENT, FLOOR PANEL. DUE TO OLD SEALANT A ROUND CARGO TIEDOWNS WAS NOT REMOVED CAUSING BULGE IN NEW PANEL. NEW SEALANT NOT APPLIED EITHER. ALSO INCORRECT MM REF USED. INSTALLED PANEL IAW SRM. REMOVED OLD SEALANT AROUND CARGO TIESDR AMTA200400377Floor Panel · corrodedCORROSION: AFT CARGO COMPARTMENT, FLOOR PANEL. FABRICATED PANEL 14 OBF IN C2 PIT IAW SRM, INSTALLED FLOORBOARD IAW AMM IN C-2 PIT.SDR AMTA200300494Light · inoperativeL-1 DOOR EMERGENCY EXIT LIGHT NOT LIGHTED. CLEANED LAMP SOCKET IAW CH 33-51-00 OF THE AMM. (M)SDR AMTA200300495Sign · brokenR-2 EMERGENCY EXIT SIGN ABOVE FLOOR IS BROKEN. REPLACED EXIT LIGHT ASSEMBLY. CHECK GOOD. REF MM 33-50-00. (M)SDR AMTA200300334Light · inoperativeLEFT AFT OVERWING EXIT WINDOW LIGHT INOPERATIVE. REMOVED AND REPLACED LIGHT ASSEMBLY IAW AMM 33-21-00-2. OPS CHECK GOOD. (M)SDR 2002F00778Actuator · faultyWHEN LOWERING THE LANDING GEAR, THE RIGHT GEAR WAS SLOW TO ILLUMINATE A GREEN LIGHT. THE GEAR WAS VERIFIED DOWN AND LOCKED BUT CHANGED TO A RIGHT GEAR UNSAFE INDICATION. MANUAL GEAR EXTENSION WAS UNSUCCESSFUL, LANDED WITH RIGHT GEAR OVERCENTER, GEAR DID NOT SDR 2002F00617Landing Gear · malfunctionedFLIGHT NUMBER 381, WHEN LOWERING THE LANDING GEAR ON APPROACH INTO DEN, THE RIGHT GEAR WAS SLOW TO ILLUMINATE A GREEN LIGHT. THE GEAR WAS VERIFIED DOWN AND LOCKED BUT CHANGED TO A RIGHT GEAR UNSAFE INDICATION, MANUAL GEAR EXTENSION WAS UNSUCCESSFUL. THE AIRC
Back to N308TZ, cancelled Aug 5, 2008