N355JB, cancelled Oct 20, 2025

Service difficulty reports · 23

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N355JB' AND deregistration_id = 'N355JB-2025-10-20'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR YENA2023121501576Unknown · unknownFLT#381, BOS-ORH. 'SEVER TURBULENCE ENCOUNTER AT 3000 FEET 10 MILES WEST OF KRIC WHILE IN IMC ALTITUDE DEVIATIONS +500/-200 FEET AIRSPEED DEVIATION +60/- KTS SPEED AT TIME OF ENCOUNTER 230 KTS. ENCOUNTER LASTED APPROXIMATELY 30 SECONDS UNABLE TO READ INSTRUMENDec 11, 2023 · N355JB · Emb ERJ190100IGW · Standard Practices/StructuresSDR YENA2023081400937Unknown · unknownFLT#582, RSW-DCA. 'RH CTR EMERGENCY LIGHT INOP; REMOVED AND REPLACED RH FWD EMERGENCY LIGHT POWER UNIT IAW AMM 33-50-01. PROBLEM NO FIX. FOUND EMERGENCY LIGHT ASSY. THE CONNECTOR NOT SECURED. SECURED CONNECTOR IAW AMM 33-50-25. OPS CHECK GOOD. NO DEFECTS NOTEAug 14, 2023 · N355JB · Emb ERJ190100IGW · Emergency LightingSDR YENA2023020600136Not Reported · not reportedFLT#1287, PVD-PBI. 'DESCENDING THRU 14,000 STRONG EXHAUST FUME SMELL BEGAN INFLIGHT COULDN'T SMELL IT. AN ODOR ISOLATION PROCEDURE FOR PACK 1 WAS PERFORMED AND THE SMELL WENT AWAY. WE TURNED THE PACK BACK ON A FEW MINUTES LATER AND IT CAME BACK. WE TURNED OFF Feb 3, 2023 · N355JB · Emb ERJ190100IGW · Air Conditioning SystemSDR YENA2022110101061Hinge Fitting · crackedDURING HEAVY MAINTENANCE: REF TC NDT-55-40-00-211-801 CRACK AND MIGRATED BUSHINGS IN HINGE FITTING # 3 LOCATED IN FWD FRONT SPAR OF RUDDER; REF TOMX WO 1989 NR -00145 RUDDER WAS REPLACED PER AIPC 27-21-05 ITEM 10, AMM 51-60-02-820-801-A AND AMM 27-21-05-000-8Oct 31, 2022 · N355JB · Emb ERJ190100IGW · Rudder StructureSDR YENA2022110101060Spar · crackedDURING HEAVY MAINTENANCE: REF TC 190-54-0014-02' CRACK AT INBOARD SPAR OF RH PYLON; REF TOMX WO 1989- NR 00241, REMOVED AND REPLACED INBOARD SPAR AT RH PYLON IAW SRM 51-41-02 PAR 4, PAR 6, SRM 51-43-03 PAR 4/5 AND SRM 51-43-04 PAR 4-5.Oct 31, 2022 · N355JB · Emb ERJ190100IGW · Nacelle/Pylon, Frame/Spar/RibSDR YENA2022110101059Rib · crackedDURING HEAVY MAINTENANCE: CRACK ON LOWER SKIN PANEL RIB 10 LH WING; REF TOMX WO 1989- NR 00163; ACCOMPLISHED REPAIR OF SKIN PANEL RIB 10 LH WING E190-SRM 57-10-01 / REPAIR 54.Oct 31, 2022 · N355JB · Emb ERJ190100IGW · Wing Main, Frame StructureSDR YENA2022110101057Floorbeam · corrodedDURING HEAVY MAINTENANCE: INITIAL INSPECTION "CPCP FINDING": CORROSION FROM MODERATE TO SEVERE ON LONGITUDINAL FLOORBEAM LOCATED IN Y= -280.0 AND FROM FR 12 TO FR 16 IN PASSENGER CABIN FLOOR STRUCTURE W1; FLOOR BEAM LOCATED IN Y= - 280.0 AND FROM FR 12 TO FR 1Oct 31, 2022 · N355JB · Emb ERJ190100IGW · Fuselage Main, Floor BeamSDR YENA2022110101056Structure · corrodedDURING HEAVY MAINTENANCE: INITIAL INSPECTION: [CPCP FINDING] CORROSION ON CUT-OUT STRUCTURE AT WASTE SERVICE PANELL; CUTOUT STRUCTURE AT WASTE SERVICE PANEL WAS REPAIRED PER EMB/190 SRM 53-23-60/REPAIR51. ALL WORK ACCOMPLISHED ON TOMX N/R# 00013.'Oct 31, 2022 · N355JB · Emb ERJ190100IGW · Fuselage Main, Plate/SkinSDR YENA2022110101055Floorbeam · corrodedDURING HEAVY MAINTENANCE: INITIAL INSPECTION "CPCP FINDING": CORROSION FROM MODERATE TO SEVERE IN LONGITUDINAL FLOORBEAM LOCATED IN Y= -280.0 AND FROM FR 12 TO FR 16 IN PASSENGER CABIN FLOOR STRUCTURE W1; FLOORBEAM LOCATED IN Y= - 280.0 AND FROM FR 12 TO FR 16Oct 31, 2022 · N355JB · Emb ERJ190100IGW · Fuselage Main, Floor BeamSDR YENA2022110101054Floor Support · corrodedDURING HEAVY MAINTENANCE: INITIAL INSPECTION "CPCP FINDING". CORROSION IN FLOOR SUPPORT LOCATED IN Y= -420.0 AND FR 12/13 IN PASSENGER CABIN FLOOR STRUCTURE W1; FLOOR SUPPORT LOCATED IN Y= -420.0 AND BETWEEN FR 12/13 IN PASSENGER CABIN FLOOR STRUCTURE W1 WAS ROct 31, 2022 · N355JB · Emb ERJ190100IGW · Fuselage Main, Plate/SkinSDR YENA2022110101053Floorbeam · corrodedDURING HEAVY MAINTENANCE: IN REF. NRC 00131(CPCP FINDING) CORROSION IN PREVIOUS DOUBLER REPAIR LONGITUDINAL FLOORBEAM LOCATED IN Y=330.0 FROM FR 13-14 IN PAX FLOOR STRUCTURE W1; DOUBLER IN LONGITUDINAL FLOORBEAM LOCATED IN Y=330.0 FROM FR13-14 IN PAX FLOOR STROct 31, 2022 · N355JB · Emb ERJ190100IGW · Fuselage Main, Floor BeamSDR YENA2022110101052Bracket · corrodedDURING HEAVY MAINTENANCE: INITIAL INSPECTION"CPCP FINDING" CORROSION IN BRACKET FLOOR SUPPORT LOCATED IN Y=-1140.0 AND FR 16 IN PAX CABIN FLOOR STRUCTURE W1; BRACKET FLOOR SUPPORT LOCATED IN Y=-1140.0 AND FR 16 IN PAX CABIN FLOOR STRUCTURE W1 WAS REPLACED PER Oct 31, 2022 · N355JB · Emb ERJ190100IGW · Fuselage Main, Plate/SkinSDR YENA2022011900031Transmitter · failedFLT # 1704, CTG-FLL(DIVERTED TO MBJ). IN FLT # 1 OIL PRESSURE INDICATION AMBER AT PSI SLOWLY BLEED DOWN TO 0 IN LESS THAN FEW MINUTES. ENGINE VIBRATION MEER 1.3=1.4 STEADY UNITL SHUTDOWN, FOLLOWED QRH PROCEDURE 6-25 FOR ENG OIL PRESSURE ABNORMAL INDICATION AN Jan 15, 2022 · N355JB · Emb ERJ190100IGW · Engine Oil Indicating SystemSDR YENA2020010620005Mau · failedEMERGENCY DECLARED. AVNX MAU FAIL IN FLT; A/C ARRIVED AT GATE WITH NO ACTIVE FAULTS. REF FIM 45-45-00-810-941-A PERFORMED MAU 2 NIC 3 MODULE RESET TEST, TEST PASSED. CONSIDERED TRANSITORY CONDITION, A/C OK FOR SVC. NO HISTORY IN AHEAD OF ITEM. SUPPLEMENTAL INFJan 2, 2020 · N355JB · Emb ERJ190100IGW · Navigation SystemSDR YENA201803240151Battery Pack · failedCENTER CEILING EMERGENCY LIGHT INOPERATIVE. R & R THE POWER SUPPLY IAW AMM 33-50-01. OPS CHECKED GOOD.Mar 24, 2018 · N355JB · Emb ERJ190100IGW · Emergency LightingSDR YENA201706050471Display · failedA/C POWERED BY STATION, PFD OVERHEAT, MFD FAIL EICAS MESSAGE. BURNING PLASTIC ODOR IN COCKPIT AND GALLEY NOTICED BY CREW. R & R THE NR 5 DISPLAY IAW AMM 31-61-01, OPS OK.Jun 5, 2017 · N355JB · Emb ERJ190100IGW · Central DisplaySDR YENA2017060500471Display · failedACFT POWERED BY STATION, PFD OVERHEAT, MFD FAIL EICAS MESSAGE. BURNING PLASTIC ODOR IN COCKPIT & GALLEY NOTICED BY CREW. R & R THE NR 5 DISPLAY IAW AMM 31-61-01, OPS OK.Jun 5, 2017 · N355JB · Emb ERJ190100IGW · Central DisplaySDR YENA201705280431Battery Pack · inoperativeDURING HEAVY MAINTENANCE, THE L2 DOOR LOWER EMERGENCY EXIT SIGN DID NOT ILLUMINATE. R & R THE BATTERY IAW AMM 33-50-01, OPS CHECKED GOOD IAW AMM 33-50-00.May 28, 2017 · N355JB · Emb ERJ190100IGW · Emergency LightingSDR YENA201705280430Floor Support · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON THE FLOOR SUPPORT BETWEEN FRAMES 13 AND 14. BLENDED THE FLOOR SUPPORT IAW SRM 51-10-03, FOUND TO BE OUT OF LIMITS IAW SRM 53-10-10. FABRICATED A REPAIR AND FILLER. REMOVED DAMAGE AREA IAW SRM 53-10-10, May 28, 2017 · N355JB · Emb ERJ190100IGW · Fuselage Miscellaneous StructureSDR YENA201705280429Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON THE LT FLOORBEAM AT FRAME 87 +5, LBL 10 ON THE UPPER SURFACE. REMOVED CORROSION, FOUND TO OUT OF LIMITS. INSTALLED DOUBLER REPAIR, TREATED, PRIMED, AND TOPCOATED IAW 51-10-03, 53-23-10, 51-23-04, 51-23-05May 28, 2017 · N355JB · Emb ERJ190100IGW · Fuselage Main, Floor BeamSDR YENA20160207107Computer · failedSTEER OFF EICAS DISPLAYED UPON LANDING. UNABLE TO ENGAGE OR RESET; PERFORMED FIM TASK 45-45-00-810-941-A AND FOUND NIC/PROC, MOD 3, MAU 2, NIC1, AT FAULT. R & R NIC 1 IAW AMM 31-41-04. TARGET LOAD ACCEPTED. NAV DATABASE UPDATED. ACFT TAXIED WITH NO STEEFeb 7, 2016 · N355JB · Emb ERJ190100IGW · Central ComputersSDR YENA20140906182Mau · failedFLIGHT DIVERTED, PILOT REPORTED DURING FLIGHT, AUTOPILOT DISENGAGED 3 DIFFERENT TIMES WITH VIBRATION FELT IN LATERAL AXIS WHILE HAND FLYING. VIBRATION ONLY FELT WHILE TURNING ACFT. ACCOMPLISHED VISUAL INSPECTION OF ACFT IAW AMM 05-50-27-210-007A IAW ENGINEERSep 6, 2014 · N355JB · Emb ERJ190100IGW · Central ComputersSDR YENA20130503093Fcu · failedFLT 1903, BOS-MSY. AIRCRAFT DIVERTED TO JFK DUE TO LOSS OF FUEL QTY INDICATIONS AFTER LEVEL OFF AT FL360 . REMOVED AND REPLACED FUEL CONDITIONING UNIT IAW AMM TASK 28-41-03. FCU SELF TEST ACCOMPLISHED IAW AMM TASK 28-41-00-710-801-A/500. SYSTEM OPS NORMAL,May 3, 2013 · N355JB · Emb ERJ190100IGW · Fuel Indicating System
Back to N355JB, cancelled Oct 20, 2025