What was found
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON THE FLOOR SUPPORT BETWEEN FRAMES 13 AND 14. BLENDED THE FLOOR SUPPORT IAW SRM 51-10-03, FOUND TO BE OUT OF LIMITS IAW SRM 53-10-10. FABRICATED A REPAIR AND FILLER. REMOVED DAMAGE AREA IAW SRM 53-10-10, AND ETD 2017-190-041003. APPLIED PROTECTIVE TREATMENT IAW SRM 53-10-10. INSTALLED THE REPAIR IAW SRM 53-10-10, AND ETD 2017-190-041003. OPEN