Service difficulty reports · 8
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model.
SDR 29GA2015052900001Bulb · inoperativeF/A EMERGENCY LIGHTS BUTTON DID NOT ILLUMINATE WITH BOTH ENGINES RUNNING. REPLACED THE BULB, OPS CHECKED GOOD.SDR 29GA2015052800002Lamp · inoperativeF/A EMERGENCY LIGHTS SWITCH DID NOT ILLUMINATE WITH BOTH ENGINES RUNNING. REPLACED THE LAMP, OPS CHECKED NORMAL.SDR 29GA2015032300002Unknown · smokeAIR RETURN DUE TO CABIN FILLED WITH SMOKE AND SMELL. SEEMED TO BE STRONGER TOWARDS AFT OF CABIN.SDR 29GA2015030900003Uplock Switch · icedGEAR HANDLE LIGHT AND HYD PUMP REMAIN ON WHILE GEAR HANDLE IS UP. CLEANED AND INSPECTED MAIN GEAR AND FOUND ICE ACCUMLUATED ON THE UPLOCK SWITCHES AND THE DOORS, CLEANED AND SWUNG THE GEAR MULTIPLE TIMES COULD NOT DUPLICATE THE PROBLEM, OK FOR RETURN TO SERVISDR 29GA2015022000001Control Handle · malfunctionedGEAR HANDLE LIGHT DID NOT ILLUMINATE ON GEAR RETRACTION, BUT GEAR RETRACTED NORMALLY ON EXTENSION LIGHT WORKED OK, PUSH TO TEST WORK OK. REPLACED LANDING GEAR CONTROL PANEL, OPS CHECK GOOD.SDR 29GA2014122200001Bushing · out of limitsCREW REPORTED UNCOMMANDED TRIM IN FLIGHT. DIVERTED AND LANDED SAFELY. BUSHING OUT OF LIMITS, REPLACED THE LT ELEVATOR. OPS CHECKED GOOD.SDR 29GA2014100100002Control Unit · intermittentWHEN GEAR HANDLE SELECTED UP GEAR UNSAFE LIGHTS DOES NOT COME ON, BUT HYDRAULIC PUMP TURNS ON AND ALL 3 GREEN LIGHTS EXTINGUISHED AT THE SAME TIME, TEST LIGHTS WERE PUSHED AND ALL LIGHTS CHECKED OK, NEXT PUMP STOPPED AND ALL INDICATIONS NORMAL, WHEN GEAR HANDLSDR 29GA20140605001Acm · odorSTRONG ODOR OF ELECTRICAL EQUIPMENT OBSERVED DURING FLIGHT. PERFORMED OPS CHECK OF SUPPLEMENTAL AIR CONDITIONER, ALSO CLEANED LT AND RT ACM DID NOT NOTE ANY ELECTRICAL BURN ODORS.