N362NC, cancelled May 14, 2026
Service difficulty reports · 32
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N362NC' AND deregistration_id = 'N362NC-2026-05-14' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N362NC' AND deregistration_id = 'N362NC-2026-05-14' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR NACA2022091700515Battery Pack · no testEMERGENCY EXIT LIGHTS FAILD TESTING DUE TO BATTERY PACK.SDR NACA2022091600511Battery Pack · no testL1 DOOR INTERIONR AND R1 DOOR EXTERIOR EMERGENCY EXIT LIGHTS FAILED FUNCTIONAL TESTINGSDR NACA2022081200001None · noneSUPPLEMENTAL INFORMATION: REMOVED DAMAGE, PERFORMED NDT. FABBED AND INSTALLED REPAIR REF ASAP EO 53-22-037 AND B737-300 SRM AS REF IN EO. EO AND 8110-3 ON FILE.SDR NACA2022080600001None · noneSUPPLEMENTAL INFORMATION: REMOVED DAMAGE, PERFORMED HFEC, LOCATED AND FABBED DOUBLER WITH FILLER FROM .040 2024-T3. INSTALLED REPAIR DOUBLER WET WITH SEALANT. AFTER INSTALL COMPLETED, REPRIMED AND APPLIED CORROSION PREVENTIVE COMPOUND. REPAIR INSTALLED IN REF SDR NACA2022061200002None · noneMAIN CABIN CENTER SEAT TRACK CRACKED STA 500B PLUS 3, FLAGGED AND MARKED AT FWD EDGE OF PALLET LOCK ASSY. SEE PWS AND PEMCO EO PD 37-53-3370 FOR DETAILS. REMOVED AND REPLACED SECTION OF SEAT TRACK, 8110-3 ATTACHED TO EO PD37-53-3370SDR DU4R2021072920092Support Fitting · crackedDURING SCHEDULED INSPECTION AT HAECO LAKE CITY, FLORIDA FOUND LEFT WING AT MLG SYPPORT FITTING, HOLE #5 HAS A CRACK INDICATION IN CHORD LAYER. S/O 660006 N/R 38573SDR DU4R2021072200091Bulb · burned outDURING SCHEDULED INSPECTION AT HAECO LAKE CITY, FLORIDA FOUND NUMBEROUS BULBS WERE OUT IN THE EMERGENCY EXIT LIGHTS ABOVE AND BELOW THE ENTRY DOORS. S/O 660006 N/R 38204.SDR DU4R2021071900090Skin · crackedDURING SCHEDULED INSPECTION AT HAECO LAKE CITY, FLORIDA FOUND L1 DOOR AT UPPER HINGE, HOLE AT BS 303.9, STR. 10L HAS TWO CRACK INDICATIONS. S/O 660006 N/R 39632SDR DU4R2021071900089Skin · crackedDURING SCHEDULED INSPECTION AT HAECO LAKE CITY, FLORIDA FOUND L1 DOOR FWD CORNER HAS CRACK INDICATION IN HOLE BS 304 - 6.5 INCHES, 2 INCHES DOWN FROM STR. 6L. S/O 660006 N/R 38447SDR DU4R2021070800087Skin · crackedDURING SCHEDULED INSPECTION AT HAECO, LAKE CITY, FLORIDA FOUND L/H WING, I/B UPPER SKIN, HOLE "B" 68, HAS A CRACK INDICATION. S/O 660006 N/R 38768SDR DU4R2021070800086Skin · crackedDURING SCHEDULED INSPECTION AT HAECO, LAKE CITY, FLORIDA FOUND L/H WING, I/B UPPER SKIN, HOLE "A" 100, HAS A CRACK INDICATION. S/O 660006 N/R 38767SDR DU4R2021070800085Skin · crackedDURING SCHEDULED INSPECTION AT HAECO LAKE CITY, FLORIDA FOUND L/H WING, I/B UPPER SKIN, HOLE "A" 75, AS A CRACK INDICATION. S/O 660006 N/R 38766SDR DU4R070800084Skin · corrodedDURING SCHEDULED INSPECTION AT HAECO, LAKE CITY, FLORIDA FOUND LEFT WING UPPER SKIN ON THE LOWER SURFACE AT WBL 174.7, THE SKIN HAS CORROSION 1" FWD OF T/E OF SKIN. S/O 660006 N/R 38756SDR DU4R2021070600083Support · crackedDURING SCHEDULED INSPECTION AT HAECO LAKE CITY, FLORIDA FOUND RIGHT WING AFT 3678R WTB PANEL SUPPORT IS CHAFED AND CRACKED AT STA. 727 STR. 19 - 20R. S/O 660006 N/R 38690SDR DU4R2021070600082Support Fitting · crackedDURING SCHEDULED INSPECTION AT HAECO LAKE CITY, FLORIDA FOUND MLG SUPPORT FITTING OF RIGHT WING AT HAS CRACK INDICATION IN HOLE #11 AND #12 IN REAR SPAR WEB LAYER. S/O 660006 N/R 38574SDR DU4R2021070200081Support · crackedDURING SCHEDULED INSPECTION, FOUND R/H MAIN LANDING W/W AFT BELLY CUTOUT RADIUS PANEL HAD A CRACKED PANEL SUPPORT. S/O 660006 N/R 38470SDR DU4R2021062400080Fitting · corrodedDURING SCHEDULED INSPECTION, FOUND LEFT MAIN LANDING GEAR FORWARD OUTBOARD LUG HAS SEVERE PITTING CORROSION. S/O 660006 N/R 38671SDR DU4R2021062300079Angle · crackedDURING SCHEDULED INSPECTION AT HAECO LAKE CITY, FLORIDA FOUND L/H WING #3 FLAP FAIRING HAS TWO CRACKED INTERNAL "L" ANGLES. S/O 660006 N/R 38745SDR DU4R202106230078Panel · corrodedDURING SCHEDULED INSPECTION AT HAECO LAKE CITY, FLORIDA FOUND R/H WING T/E AILERON, #3 AILERON HINGE FITTING, PANEL ATTACH BOLT HOLES HAVE CORROSION IN AND AROUND THEM. S/O 660006 N/R 38407SDR DU4R2021060900077Angle · dentedDURING SCHEDULED INSPECTION AT HAECO LAKE CITY, FLORIDA FOUND DENT IN FWD LWR ANGLE OF MAIN CARGO DOOR CUTOUT DOOR JAMB. S/O 660006 N/R 38238SDR DU4R2021060400076Bracket · puncturedDURING SCHEDULED INSPECTION AT HAECO, LAKE CITY, FLORIDA FOUND WEB BRACKET HAS A PUNCTURE AT BS 344, STR. 16L. S/O 660006 N/R 38669SDR DU4R2021060400075Hinge Fitting · corrodedDURING SCHEDULED INSPECTION AT HAECO LAKE CITY, FLORIDA FOUND R/H WING T/E AILERON, #2 AILERON HINGE FITTING, PANEL ATTACH BOLT HOLES, HAVE CORROSION IN AND AROUND THEM. S/O 660006 N/R 38406SDR DU4R2021051700074Floor Panel · corrodedDURING SCHEDULED INSPECTION AT HAECO LAKE CITY, FLORIDA FOUND AFT CARGO COMPARTMENT FLOOR PANEL 1534X HAS MULTIPLE AREAS OF SURFACE ETCH CORROSION. S/O 660006 N/R 38253SDR DU4R2021051400072Structure · damagedDURING SCHEDULED INSPECTION AT HAECO LAKE CITY, FLORIDA FOUND A DENT AND CRACK IN THE L/H TRAILING EDGE OF THE MID FLAP THAT WAS STOP DRILLED AND SEALED. S/O 660006 N/R 38151SDR DU4R2021050700071Shear Web · crackedDURING SCHEDULED INSPECTION AT HAECO, LAKE CITY, FLORIDA FOUND SHEAR WEB FRAME 592.4 OF FWD CARGO DOOR AFT FRAME IS CRACKED. S/O 660006 N/R 38630SDR DU4R2021050700070Transition Panel · corrodedDURING SCHEDULED INSPECTION AT HAECO, LAKE CITY, FLORIDA FOUND AFT CARGO COMPARTMENT, BS 727D +10 - 790 LBL 24 TRANSITION PANEL HAS MULTIPLE AREAS OF CORROSION AND 2 EACH LOOSE FRAME ATTACH RIVETS. S/O 660006 N/R 38261SDR DU4R2021050400069Attach Angle · corrodedDURING SCHEDULED INSPECTION AT HAECO LAKE CITY, FLORIDA FOUND MULTIPLE AREAS OF CORROSION ON FLOOR PANEL CROSS ATTACH ANGLE IN AFT CARGO COMPARTMENT AT BS947.5, LBL-24 - RBL-24. S/O 660006 N/R 38282SDR DU4R2021050300068Attach Fitting · corrodedDURING SCHEDULED INSPECTION AT HAECO LAKE CITY, FLORIDA FOUND R/H MLG SUPPORT BEAM STABILIZER ATTACH FITTING HAS FRETTING ON BOTH LUG FACES. S/O 660006 N/R 39463SDR DU4R2021050300067Transition Panel · corrodedDURING SCHEDULED INSPECTION AT HAECO LAKE CITY, FLORIDA FOUND TRANSITION PANEL IN AFT CARGO COMPARTMENT, AT BS 787 TO BS 947.5, LBL 24, HAS MULTIPLE AREAS OF CORROSION. S/O 660006 N/R 38264SDR NACA2020120900020Flap System · malfunctionedDISCREPANCY: MISSED APPROACH DUE TO FLAPS NOT DEPLOYING AND SPEED BRAKE NOT DEPLOYING. NO FLAP ASSYMETRY AND NO FLAP DISAGREE. CORRECTIVE ACTION: PERFORMED FLAP OPERATION CHECK & SPEED BRAKE OPERATIONAL CHECK WITH NO BINDING OR INABILITY TO MOVE HANDLES. INSDR NACA2020112700019Skin · crackedDISCREPANCY: CRACK ON LEFT SIDE FUSELAGE, 14 INCHES FWD OF BS 500, 2.75 INCHES ABOVE S26L, 1.5 INCHES LONG. CUT OUT DAMAGE, FABBED DOUBLER AND INSTALLED, PER REF B737-300 SRM 53-00-01 REPAIR 31 DETAIL XIX AND PEMCO EA NR PD37-53-3220.SDR NACA2020110600018Start Valve · inoperativeDISCREPANCY: DURING CLIMB NR 2 ENGINE EGT LIGHT ILLUMINATED A/T DISCONNECT MANUAL THRUST REDUCTION. LARGE THRUST LEVER SPLIT FOR EQUAL THRUST. A/P & AT ILS ENGINE PERFORMANCE NORMAL. CORRECTIVE ACTION: PERFORMED VISUAL CHECK OF INLET AND EXHAUST, NO DEFECTS