N406NV, cancelled May 29, 2020
Service difficulty reports · 35
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N406NV' AND deregistration_id = 'N406NV-2020-05-29' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N406NV' AND deregistration_id = 'N406NV-2020-05-29' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR JR2R20161004491Pan · crackedL1 DOOR PAN CRACKED AT THE FWD UPPER CORNER. REPAIRED L1 DOOR PAN IAW EA 40-2016-314.SDR JR2R20160930393Scoop · crackedVERTICAL STABILIZER RAM AIR SCOOP CRACKED. REPAIRED VERTICAL STABILIZER RAM AIR SCOOP IAW EA 40-2016-308.SDR WX0A201607193177Control Valve · crackedDURING CLIMB OUT, PASSING 9000 FT, TAIL COMPARTMENT HIGH LIGHT AND MASTER WARNING RED LIGHTS ILLUMINATED. PRFORMED MEMORY ITEMS PER QRH 21.4 PERFORMED QRH 21.4 AND LIGHT EXTINGUISHED WITH RIGHT THROTTLE RETARTED. FOLLOWED 21.4 7A-B EMERGENCY DECLARED, RETURSDR WX0A2015121573044Unknown · smokeSMOKE IN CABIN WITH APU ON. COMPLIED WITH TC 21-059-002.SDR WX0A2015092472886Smoke Detector · false activationAFT LT LAVATORY SMOKE DETECTOR CHIMING. R & R AFT LT LAVATORY SMOKE DETECTOR IAW CMM 26-10-02. OPERATIONS CHECKED GOOD. THIS CLEAR MEL 26-07 SIT 1 CAT C DMI 19912. PLACARDS REMOVED & SYS RESTORED TO ORIGINAL CONFIGURATION.SDR WX0A2015081172786Bolt · looseOIL QTY DECREASED FROM 9 QTS TO 5 QTS DURING CLIMB. PERFORMED EQRH 72.15. OIL STABILIZED AT 5 QTS LANDED WITH 4 QTS. FOUND LOOSE BOLTS IAW ON NR 4 BEARING OIL BREATHER TUBE ATTACH POINT UPSTREAM. SECURED BOLTS IAW AMM 79-20-02-2-0 10 B. LEAK CHECKED GOOD SDR WX0A2015062672700Clamp · out of positionTAIL COMPARTMENT TEMP HIGH AT 3200 MSL. COMPLIED WITH QRH 21.4. LIGHT WENT OUT 1:10 AFTER STEP 3 BUT BEFORE CONTINUING TO STEP 4. APU WAS RUNNING WITH AIR OFF. REF WO 00260195 -1 & -2 TC 21-059-010 & TC 21-059-005. FOUND LT HEAT EXCHANGER CLAMP OFF. SECUSDR WX0A2015062672694Power Supply · damagedFOUND ON WAKE UP, EMER LIGHTS INOPERATIVE AT ROWS 22 - 25. REPLACED BATTERIES. REPLACED POWER SUPPLY DUE TO DAMAGE. OPERATIONS CHECKED GOOD IAW AMM 33-51-01.SDR WX0A2015062672693Battery · dischargedFOUND ON WAKE UP, EMER LIGHTS INOPERATIVE AT ROWS 17 - 19. REPLACED BATTERIES. OPERATIONS CHECKED GOOD IAW AMM 33-51-01.SDR WX0A2015051172584Battery Pack · dischargedEMERGENCY OVERHEAD LIGHTS INOPERATIVE AT SEATS 16, 18L & 20. REPLACED CABIN EMER LIGHT BATTERY PACK AS REQUIRED IAW AMM 33-53-00. OPERATIONS CHECKED GOOD.SDR WX0A072350Portable Light · inoperativePORTABLE LIGHT EMER AT L1 DOOR IS INOPERATIVE. R & R PORTABLE EMER LIGHT IAW AMM 33-533-00-5 CONFIG 1. LIGHT CHECK IS GOOD.SDR WX0A2014090972146Wire · brokenLEFT AFT STAIRWAY EMER LIGHT INOPERATIVE. REPLACED BROKEN WIRE TO LIGHT. OPERATIONS CHECKED GOOD IAW AMM 33-53-00.SDR WX0A2014081172088Slide · unserviceableL2 SLIDE INDICATOR IN THE RED. R & R L2 DOOR SLIDE IAW AMM 25-62-00 & TC R0902502.SDR WX0A2014070772009Finger Doubler · corrodedFUSELAGE FINDER DOUBLER CORRODED OUT OF LIMITS STATION 231 - 235 ABOVE LONGERON 26L. CUT OUT DAMAGED AREA, FABRICATED FINGER DOUBLER, INTERNAL DOUBLERS, REPAIR PARTS. LOCATED DRILLED & INSTALLED FLUSH DOUBLER REPAIR IAW SRM 53-04 FIG 12C.SDR WX0A071984Light · inoperativeAFT STAIRS EMER LIGHTS INOPERATIVE. R & R AFT AIR STAIRS EMER LIGHTS 2 IAW AMM 33-53-00. OPERATIONS CHECKED GOOD.SDR WX0A071960Battery · dischargedMAIN CABIN EMER LIGHTS INOPERATIVE. REPLACED BATTERIES FOR EFFECTED LIGHTS IAW AMM 33-53-00. OPERATIONS CHECKED GOOD.SDR WX0A071979Switch · intermittentAFTER TAKEOFF WE NOTICED PRESSURIZATION WAS NOT OPERATING NORMALLY. THE FLIGHT ATTENDANT INFORMED US THAT THE CABIN WAS GETTING HAZY & THE AFT RT SMOKE ALARM HAD ILLUMINATED. TURNED OFF THE PACK & THIS SEEMED TO CORRECT THE PROBLEMS. PERFORMED ENG RUNS, OPESDR WX0A071934Power Supply · inoperativeFORWARD EMERGENCY LAMPS INOPERATIVE IN COCKPIT & ENTRY WAY CEILING. R & R FWD ENTRY WAY BATTERY POWER SUPPLY ASSEMBLY IAW AMM 33-53-00 & 33-53-01, OPERATIONS CHECKED GOOD.SDR WX0A071930Battery · dischargedNUMEROUS CABIN EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERIES IAW MM 33-51-00, OPERATIONS CHECKED GOOD.SDR WX0A071929Battery · dischargedFLIGHT DECK EMERGENCY LIGHTS INOPERATIVE. INSTALLED NEW BATTERIES FOR FLIGHT DECK EMERGENCY LIGHTS IAW MM 33-51-00, OPERATIONS CHECKED GOOD.SDR WX0A071928Battery · dischargedEMERGENCY STBY LIGHT IN FWD CABIN INOPERATIVE. INSTALLED NEW BATTERIES FOR FWD CABIN EMERGENCY LIGHT IAW MM 33-51-00, OPERATIONS CHECKED GOOD.SDR WX0A071915Power Supply · inoperativeEMERGENCY LIGHTS ON FLIGHT DECK WILL NOT ILLUMINATE DURING CHECK. R & R POWER SUPPLY IAW AMM 33-53-00, OPERATIONS GOOD.SDR WX0A20131004716Battery · inoperativeAFT F/A FLASHLIGHT RED LIGHT DOES NOT BLINK. R & R FLASHLIGHT BATTERY IAW AMM 25-60-00, OPS CHECKED GOOD.SDR WX0A2013091071688Seat Track · corrodedSEAT TRACK HAS CORROSION AT LBL 44 BETWEEN FS 1136 AND 1139. REPAIRED SEAT TRACK IAW SRM 53-05.SDR WX0A201309107187Pan · corrodedFLOOR PAN CORRODED BETWEEN BS 148.55 AND 160.00. REPAIRED AREA IAW SRM 53-01.SDR WX0A2013091071686Seat Track · chafedCABIN RT SEAT TRACK CHAFED OUT OF LIMITS, BS 1155, RBL 22. CUTOUT DAMAGED AREA, LOCATED, DRILLED, AND INSTALLED REPAIRS IAW SRM 53-05, FIG 4A.SDR WX0A2013083071675Tab · damagedRIGHT ELEVATOR CONTROL TAB T/E DAMAGED AT STATION XHS 69; APPROX 3 FT FROM OTBD END. REMOVED DAMAGED SKIN, FABRICATED DOUBLER AND ACCOMPLISHED HOT BOND REPAIR IAW SRM 55-04, PARA 3, PAGE 9. DOUBLER MEASURES 4".SDR WX0A071258Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE ASDR WX0A070994Battery Pack · dischargedIT HAS BEEN REPORTED BY THE FLIGHT CREW THE EMERGENCY EVACUATION LIGHTING SYSTEM HAS BEEN FOUND TO BE DEFECTIVE. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERY PACK AND MADE ALL REQUIRED CORRECTIONS AND OPERATSDR WX0A070966Light · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE EMERGENCY EXIT LIGHT ASSY AND MADE ASDR WX0A070965Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A070883Light · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE EMERGENCY EXIT LIGHT ASSY AND MADE ASDR WX0A070589Pan · corrodedFORWARD CARGO DOOR CUTOUT PAN IS CORRODED AROUND RIV-NUT INSERTS. REPAIRED DOOR PAN IAW MD80 SRM 53-01 FIG 1, 53-14-2 PG 2, 51-30-01 & 53-05 FIG 44.SDR WX0A070508Battery Pack · no testDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR WX0A070276Battery Pack · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTER
Back to N406NV, cancelled May 29, 2020