N424NV, cancelled May 7, 2022

Service difficulty reports · 44

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N424NV' AND deregistration_id = 'N424NV-2022-05-07'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR JR2R10082017350Beam · corrodedFOUND THE DOOR FRAME BEAM TO BE CORRODED. REMOVED AND REPLACED THE BEAM IAW SRM 51-30-5.Oct 8, 2017 · N424NV · Doug MD83 · Fuselage Main, StructureSDR JR2R2017100331Rib · crackedVERTICAL STAB LOWER L/E FIFTH RIB UP FROM BOTTOM, CRACKED AT LOWER ATTACHED FASTENER, RT SIDE. REMOVED AND REPLACED DAMAGED THE RIB IAW 51-30-2, FIG 19-20, AND 51-30-5.Oct 7, 2017 · N424NV · Doug MD83 · Vertical Stabilizer, Spar/RibSDR JR2R20171007333Rib · crackedVERTICAL STAB LOWER L/E, FOURTH RIB, UP FROM BOTTOM CRACKED AT LOWER ATTACHED FASTENER, RT SIDE. REPAIRED THE RIB IAW 55-02, FIG 27, SHEET 3 AND 4. INSTALLED IAW SRM 51-30-2, FIG 19-20, AND 51-30-5.Oct 7, 2017 · N424NV · Doug MD83 · Vertical Stabilizer, Spar/RibSDR JR2R20171007332Rib · crackedVERTICAL STAB LOWER L/E, THIRD RIB UP FROM BOTTOM, CRACKED AT LOWER ATTACH FASTENER LT SIDE. REMOVED AND REPLACED DAMAGED RIB IAW SRM 51-30-2, FIG 19-20, AND 51-30-5.Oct 7, 2017 · N424NV · Doug MD83 · Vertical Stabilizer, Spar/RibSDR JR2R20171007326Skin · corrodedFUSELAGE SKIN CORRODED. REPAIRED THE SKIN IAW EA 42-2017-024.Oct 7, 2017 · N424NV · Doug MD83 · Fuselage Main, Plate/SkinSDR JR2R20171006092Skin · corrodedFORWARD LAVATORY SERVICE DOOR EXTERNAL SKIN CORRODED BETWEEN SKIN AND INTERNAL DOUBLER. REPAIRED FWD LAV SERVICE DOOR FWD LOWER CORNER FUSELAGE CUTOUT IAW EA 25-2017-110.Oct 6, 2017 · N424NV · Doug MD83 · Fluid Service DoorsSDR JR2R10171006124Door · crackedLEFT WING OTBD BUTTE DOOR, OTBD SIDE CRACKED. REMOVED AND REPLACED BUTTE DOOR IAW SRM 51-30-5, PARA 7.Oct 6, 2017 · N424NV · Doug MD83 · Wing Main, Frame StructureSDR JR2R20171005252Angle · damagedAFT CARGO ANGLE CRACKED OR HAS DEEP GOUGE BS 1154, STRINGER 21R. REMOVED AND REPLACED THE ANGLE IAW SRM 51-30-5.Oct 5, 2017 · N424NV · Doug MD83 · Fuselage Miscellaneous StructureSDR JR2R20171004194Stiffener · crackedAFT FUSELAGE FRAME CRACKED ON AFT SIDE OF FRAME INNER LIP AROUND FASTENER. REMOVED AND REPLACED EXISTING CRACKED REPAIR STIFFENER IAW MD80 SRM 51-30-5.Oct 4, 2017 · N424NV · Doug MD83 · Fuselage Miscellaneous StructureSDR JR2R20171004123Attach Bracket · crackedLT WING TRAILING EDGE OUT BOARD BUTE DOOR ATTACH BRACKET IS CRACKED. REMOVED AND REPLACED LT WING TRAILING EDGE OUT BOARD BUTE DOOR ATTACH BRACKET IAW SRM 51-30-5 PG 12 STEP 7 AND 51-30-2 PG 26B STEP 8.Oct 4, 2017 · N424NV · Doug MD83 · Wing, Attach FittingsSDR JR2R201100817344Skin · crackedCRACK FOUND IN THE SKIN AND DOUBLER AT LOWER AFT CORNER OF AIRSTAIR DOOR.Oct 3, 2017 · N424NV · Doug MD83 · Fuselage Main, Plate/SkinSDR WX0A2016040473128Actuator · inoperativeIN CRUISE, TRANSFER LOCKOUT, LIGHT ILLUMINATED. QRH 21.10 COMPLIED & LIGHT REMAINED ILLUMINATED. TROUBLE SHOT & TESTED SYS IAW AMM 21-32-00. BIT CHECK OF NR 1 CONTROLLER SHOWS ACTUATOR FAULT. R & R CABIN OUTFLOW VLV ACTUATOR ASSEMBLY IAW AMM 21-32-05. OPEApr 2, 2016 · N424NV · Doug DC983 · Pressure Regulator/Outflow ValveSDR WX0A2016040573129Spar Cap · crackedLEFT WING FWD SPAR, LOWER CAP UPPER SURFACE, FWD FLANGE CORRODED AT STATION XFS 570. DURING REPAIR, A .200"" CRACK WAS NOTED, BETWEEN TWO FASTENER HOLES. DAMAGE WAS REPAIRED IAW EA 30-2016-093 DATED 03 26 16.Mar 31, 2016 · N424NV · Doug DC983 · Wing SparSDR JR2R20160331508Spar Cap · crackedLEFT WING FWD SPAR LOWER CAP, UPPER SURFACE FWD FLANGE CORRODED AT STATION XFS 570. DURING THE REPAIR, A .200" CRACK WAS NOTED, BETWEEN TWO FASTENER HOLES. DAMAGE WAS REPAIRED IAW STS EA 30-2016-093 DATED 03 26 16.Mar 31, 2016 · N424NV · Doug MD83 · Wing SparSDR JR2R20160331493Floor Panel · corrodedFLOOR PANEL AT R1 DOOR GIRT BAR FLOOR LATCHES CORRODED OUT OF SRM 53-01 LIMITS. REPLACED FLOOR PANEL WITH SERVICEABLE PART IAW SRM 51-10-4.Mar 31, 2016 · N424NV · Doug MD83 · Fuselage Floor PanelSDR WX0A2015113000025Lamp · inoperativeEMERGENCY EXIT LAMP INOPERATIVE AT ROW 26. REPLACED THE LAMP IAW AMM 33-53-00, OPS CHECKED GOOD.Dec 1, 2015 · N424NV · Doug DC983 · Emergency LightingSDR WX0A2015113000022Smoke Detector · false activationAFTER LANDING, SMOKE ALARM FOR AFT RT LAV WENT OFF, F/A REPORTS NO EVIDENCE OF SMOKE OR FIRE. PLACED AFT RT LAV SMOKE DETECTOR ON MEL 26-07 S1, AUTHORIZATION NR 21374, EXPIRES 12/6/15, CAT C. MAINTENANCE ACTION COMPLETED, PLACARD INSTALLED."Nov 26, 2015 · N424NV · Doug DC983 · Smoke DetectionSDR WX0A2015062672701Warning System · false activationTAIL COMPARTMENT HIGH LIGHT ON OAP AT ROTATION QRH 21.4. LIGHT EXTINGUISHED AFTER 60 SEC. REF WO 00260196-1 & 0020196-2. COMPLIED WITH TC 21-059-010 & TC 21-059-005.Jun 25, 2015 · N424NV · Doug DC983 · Overheat DetectionSDR WX0A2015062672696Battery · dischargedFOUND ON WAKE UP, FWD CABIN EMER LIGHTS INOPERATIVE. REPLACED BATTERIES. OPERATIONS CHECKED GOOD IAW AMM 33-51-01.Jun 25, 2015 · N424NV · Doug DC983 · Emergency LightingSDR WX0A2015061072642A/C Pack · odorFLIGHT ATTENDANT'S REPORTED A STRONG PLASTIC BURNING SMELL SHORTLY AFTER TAKEOFF. VERIFIED ODOR COMING FROM LT PACK DURING POWER RUNS. DEFERRED LT PACK IAW MEL 21-01, CAT C, EXPIRES 6 15 15, PLACARD INSTALLED.Jun 5, 2015 · N424NV · Doug DC983 · Cabin Cooling SystemSDR WX0A2015040872519Power Supply · inoperativeFORWARD WING EMER EXIT LIGHTS INOPERATIVE. R & R EMER EXIT LT POWER SUPPLY IAW 33-53-01. FWD WING EMER EXIT LTS CHECKED GOOD.Apr 4, 2015 · N424NV · Doug DC983 · Emergency LightingSDR WX0A2015040872509Light · brokenTAIL COMPARTMENT RT AFT EMER EXIT LIGHT INOPERATIVE & ASSEMBLY BROKEN. R & R RT AFT TAIL COMPARTMENT E & E LIGHT ASSEMBLY. OPERATIONS CHECKED NORMAL IAW AMM 33-53-00.Apr 2, 2015 · N424NV · Doug DC983 · Emergency LightingSDR WX0A2015030472445Light · inoperativeRIGHT EXTERIOR EMER EXIT LIGHT INOPERATIVE. REPLACED RT OVERWING EMER EXIT LIGHT ASSEMBLY IAW AMM 33-53-00. OPERATIONS CHECKED GOOD.Mar 3, 2015 · N424NV · Doug DC983 · Emergency LightingSDR WX0A2015022372434Flap · crackedLEFT OTBD FLAP TE CRACKED. REPAIRED DAMAGED SECTION OF LT OTBD FLAP TE IAW SRM 57-03.Feb 21, 2015 · N424NV · Doug DC983 · Trailing Edge FlapsSDR WX0A2014102172214Proximity Sensor · faultyGEAR RETRACTION ON TAKEOFF RT GEAR INDICATION REMAINED RED WITH GEAR HANDLE UP. RAN QRH 32.9, HYD PRESS & QTY NORMAL. R & R RT MLG UPLOCK & DOWNLOCK PROXIMITY SENSORS IAW AMM 32-60-05. PERFORMED PSEU CHECKS ON REPLACED SENSORS WITH GO & NO GO GAUGE & BITE. Oct 10, 2014 · N424NV · Doug DC983 · Landing Gear Position and WarningSDR WX0A2014090472133Apu · leakingIMMEDIATELY AFTER TAKEOFF ALL FLIGHT ATTENDANT`S & FIRST OFFICER`S SMELLED A STRONG CHEMICAL ODOR, SMELL DISSIPATED OVER 10 MINUTES. QRH 26.5 REFERENCED. PACKS ON TAKEOFF IAW WORK ORDER 00233607 NR 1, TASK CARD F0592102 & TASK CARD S0592101, APU LEAK IDENTIFAug 31, 2014 · N424NV · Doug DC983 · APU Core EngineSDR WX0A071866Battery · dischargedFWD CABIN OVERHEAD EMERGENCY LIGHTS INOPERATIVE. R & R EMERGENCY BATTERIES AT FWD GALLEY POSITION IAW 33-53-00, OPERATIONS CHECKED GOOD.Feb 25, 2014 · N424NV · Doug MD83 · Emergency LightingSDR WX0A201309260005Battery Pack · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSP, MX REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYS WOULD NOT TEST. MX R & R BATTERY PACK AND OPS CHECKED IAW AMM 33-50-00, SYS OPS CHECKED NORMAL. ACFT RETURNED TO SERVICE.Sep 20, 2013 · N424NV · Doug DC983 · Emergency LightingSDR WX0A201309260004Battery Pack · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, MX REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYS WOULD NOT TEST. MX R & R BATTERY PACK AND OPS CHECKED IAW AMM 33-50-00, SYS OPS CHECKED NORMAL. ACFT RETURNED TO SERVICE.Sep 17, 2013 · N424NV · Doug MD83 · Emergency LightingSDR WX0A201308130054Battery Pack · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, MX REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYS WOULD NOT TEST. MX R & R POWER SUPPLY BATTERY PACK AND OPS CHECKED IAW AMM 33-50-00, SYSTEM OPS CHECKED NORMAL. ACFT RETURNED TO SERVICE.Aug 1, 2013 · N424NV · Doug DC983 · Emergency LightingSDR WX0A201308010042Battery Pack · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MX DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYS WOULD NOT TEST. MX R & R BATTERY PACKS AND OPS CHECK WAS ACCOMPLISHED IAW AMM 33-50-00, SYS OPS CHECKED NORMAL. ACFT RETURNJul 25, 2013 · N424NV · Doug DC983 · Emergency LightingSDR WX0A2013070800024Battery Pack · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK, MX REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MX R & R BATTERIES IN THE POWER SUPPLY AND MADE ALL REQUIRED CORRECTIONS AND OPS CHECK WAS ACCOMPLISHED IAW AMM 33-50-00, SYS OPS CHECJun 28, 2013 · N424NV · Doug DC983 · Emergency LightingSDR WX0A2013041571558Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE AApr 1, 2013 · N424NV · Doug MD83 · Emergency LightingSDR WX0A201301140085Battery Pack · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, MAINTENANCE REPORTED A PORTION OF THE EMERGENCY LIGHTS WOULD NOT TEST. MAINTENANCE REMOVED AND REPLACED BATTERY PACK IN POWER SUPPLY. OPS CHECK WAS ACCOMPLISHED PER AMM 33-50-00, SYSTEM OPS CHECKED NORMALJan 14, 2013 · N424NV · Doug MD83 · Emergency LightingSDR WX0A071474Bulkhead · crackedRIGHT CANTED BULKHEAD 1463 AS 2 EACH CRACKS AT LONGERON 17R AND 18R. STOP DRILLED CRACKS, FABRICATED REPAIR DOUBLERS AND SHIMS.Jan 9, 2013 · N424NV · Doug MD83 · Fuselage Main, BulkheadSDR WX0A071472Drag Angle · crackedLEFT CANTED BULKHEAD 1463 DRAG ANGLE CRACKED IN EXISTING DOUBLER. REMOVED AND REPLACED DRAG ANGLE AT 181.Jan 9, 2013 · N424NV · Doug MD83 · Fuselage Miscellaneous StructureSDR WX0A071471Drag Angle · crackedRIGHT CANTED BULKHEAD 1463 DRAG ANGLE CRACKED. REMOVED DAMAGED ANGLE. FABRICATED NEW ANGLE AND INSTALLED.Jan 9, 2013 · N424NV · Doug MD83 · Fuselage Miscellaneous StructureSDR WX0A071418Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERNov 14, 2012 · N424NV · Doug MD83 · Emergency LightingSDR WX0A071373Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE AOct 31, 2012 · N424NV · Doug MD83 · Emergency LightingSDR WX0A071285Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERAug 28, 2012 · N424NV · Doug MD83 · Emergency LightingSDR WX0A071276Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERAug 19, 2012 · N424NV · Doug MD83 · Emergency LightingSDR WX0A071211Power Supply · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE AMay 26, 2012 · N424NV · Doug MD83 · Emergency LightingSDR WX0A071147Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERMar 28, 2012 · N424NV · Doug MD83 · Emergency LightingSDR WX0A071146Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERMar 21, 2012 · N424NV · Doug MD83 · Emergency Lighting
Back to N424NV, cancelled May 7, 2022