Service difficulty reports · 56
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model.
SDR MALA110006Power Supply · failedDURING TC 335003 EMERGENCY POWER SUPPLY 20LN FAILED CAPACITY CHECK. REPLACED EMERGENCY POWER SUPPLY 20LN IAW AMM 33-50-10. EMERGENCY POWER SUPPLY SYS OPS CHECKS GOOD IAW AMM 33-50-00.SDR MALA100139Firewall · chafedRT NACELLE FIREWALL CHAFED .675 X .25 X .039 DEEP. APPROX 1.375" FWD AND INBD OF DEICE LINE/FIREWALL UNION. ACCOMPLISHMENT OF INTERIM REPAIR IAW REPAIR STATEMENT 340SDS021032 DATED 8/21/2010 AND EOS54246 PROVIDES CONTINUED OPERATION UNTIL 10/12/2010 (N4K, 30/SDR MALA100100Power Supply · inoperativeEMERGENCY BATTERY 23LN FAILED EMERGENCY LIGHT CHECK. R & R EMERGENCY BATTERY 23LN IAW SF340, AMM 33-50-00 PERFORMED FUNCTION TEST IAW AMM 33-50-00-05-1. FUNCTION TEST GOOD ON LIGHTS. PN ON/OFF 3301-51 SN OFF 1348 SN ON 2174.
See all 56 reports