N501UA, cancelled May 11, 2015
Service difficulty reports · 59
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N501UA' AND deregistration_id = 'N501UA-2015-05-11' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N501UA' AND deregistration_id = 'N501UA-2015-05-11' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2012070503604Circuit Card · faultyFALSE FLAP WARNING, RTFL. TROUBLESHOT PER FIM 32 09 03. FOUND LOGIC CARD NUMBER 011 BAD IN PROX SWITCH ELECT UNIT. REMOVED AND REPLACED LOGIC CARD PER AMM AND RAN TEST OF PROX SWITCH ELECT UNIT. ALL CHECKED GOOD. OK TO CONTINUE.SDR UALA2012070103496Engine · making metalNR 1 ENGINE ISSUE, RTFL. METAL IN TAILPIPE NR 1 ENGINE. REPLACED NR 1 ENGINE PER TO D 71-00-02.SDR UALA2012052702987Skin · delaminatedFOUND DELAMINATION ON NR 5 LEADING EDGE SLAT INBD TRAILING EDGE WEDGE, APPROX 19 X 7 1-2 INCH AREA. TOP AND BOTTOM DELAMINATION. ACCOMPLISHED MM 27-81-01 THRU STEP D (13) PAGE 403. REMOVED AND REPLACED SLAT FOR REPAIR. INSTALLED SLAT 3 MAIN TRACK BOLTS ANDSDR UALA2012050402640Duct · leakingUNIDENTIFIABLE NOISE IN FIRST CLASS CABIN. MULTIPLE LEAKS IN CTR DISTRIBUTION DUCT IN AREA OF UPPER BEACON. LOUD VIBRATION WITH DUCTS PRESSURIZED AT UPPER BEACON ACCESS POINT. EXTERNALLY SEALED AFFECTED AREAS OF OVERHEAD CENTER DISTRIBUTION DUCT. NO FURTHESDR UALA2012021500900Feeder Cable · inoperativeEMERGENCY EVACUATION FLOOR LIGHTING INOPERATIVE BETWEEN ROWS 28-36. REPLACED POWER FEEDER CABLE 586-0820 AT SEAT ROW 34ABC AND OP CHECKED PER MM.SDR UALA2011090704833Valve · leakingLEFT WING SUMP VALVE LEAKING APPROX 90 DROPS PER MINUTE. REPLACED SUMP DRAIN CHECK VALVE O-RING, NO HELP. FUEL COMING FROM AROUND HOUSING. LEFT WING FUEL TRANSFERED OUT AND WING SUMPED AS PREP WORK FOR DEN EFS. REPLACED SUMP VALVE AND RESEALED SUMP VALVE CSDR UALA2011061302889Filter · faultyF/A REPORTED AIRFLOW IN CABIN EXTREMELY LOUD FROM OVERHEAD DUCTING. AIRFLOW SUFFICIENT THROUGHOUT A-C BUT STRONGER AND NOISIER IN SEVERAL AREAS. SUGGEST A-C MAY NEED ENTIRE A-C DUCT CLEANING TO EQUALIZE AIRFLOW THROUGHOUT CABIN. NOISE IS FROM RISERS ON BOTHSDR UALA2010110304076Slide · misinstalledDOOR 2 RH SLIDE MIS-INSTALLED. INSTALLED CORRECTLY ON JIC 5R52I1890, SEQ. 168.SDR UALA2010100803752Circuit Card · faultySTATUS MESSAGE "R ENG FIRE LP 1". TROUBLESHOT IAW MM, REPLACED M681 CARD, NO HELP. ALSO TRIED REPLACING DETECTOR NR2, NO HELP. NEED MORE TIME TO TROUBLESHOOT. REPLACED NR 2 ENG LOWER RT FIRE LOOP. PROBLEM STILL THERE. ALL LOOP RESISTANCES ARE WITHIN LIMITS.SDR UALA2010052401759Light · inoperativeFOUND EMERGENCY EGRESS LIGHTING STRIP FWD OF MID LAV DOOR NOT WORKING. REPLACED EGRESS STRIP FWD OF LAV DOOR.SDR UALA2010031200836Flashlight · activatedFLIGHT ATTENDANT REPORT: EMERGENCY FLASHLIGHT AT DOOR 2L, OUTBOARD POSITION, WAS USED. REPLACED EMERGENCY FLASHLIGHT.SDR UALA2009122103955Control Unit · malfunctionedHIGH STAGE BLEED ILLUM, FLIGHT DIVERTED. FROM SNA WITH BLEEDS OFF DUE TO EXCESS FUEL, POSSIBLE TRIGGER OF BOTH FAULTS. FOUND LT & RT HIGH STAGE PILOT CONTROL OVER PRESSURE INDS POPPED. RESET LT HIGH STAGE PILOT CONTROL, REPLACED RT HIGH STAGE PILOT CONTROL. RASDR UALA2009082702688Light · faultyDOOR 2LT SLIDE LIGHT NOT ON WITH DOOR SLIDE IN ARMED POSITION. REPLACED LIGHT ASSY, NO HELP. REPLACED WITH LED STYLE INDICATOR.SDR UALA2009082102581Microphone · inoperativeCAPT O2 MASK MICROPHONE WILL NOT TEST. REPLACED MASK.SDR UALA2009062201751Lamp · defectiveLEFT ENG FIRE HANDLE LIGHT DIM DURING FIRE TEST. RELAMPED FIRE HANDLE.SDR UALA2009012000223Container · delaminatedLT OVERWING SLIDE CONTAINER BOX IS DELAMINATED. REMOVED AND REPLACED LEFT OVERWING SLIDE.SDR UALA2009012000222Girt Bar · out of adjustL-1 DOOR ARM-DISARM LEVER BINDING. ADJUSTED GIRT BAR.SDR UALA2009012000221Power Supply · dischargedSEAT ROW 16-23 ABC, EEL LIGHTS INOP. REMOVED AND REPLACED POWER SUPPLY M10770 AND OPS CHECK GOOD.SDR UALA2009011900208Frame · crackedCRACKS ON FRAMES BS 680 AT STR 12 AND STR 11 RT. MAJOR REPAIR ACCOMPLISHED: REMOVED AND REPLACED P/N 143N8334-28 FRAME INTERCOSTAL. PERFORMED GIRT BAR PROX SENSOR, OPS CHECK GOOD.SDR UALA2009011900207Frame · crackedCRACK ON FRAME AT BS 680 AND STRINGER 12L. MAJOR REPAIR ACCOMPLISHED: REMOVED AND REPLACED P/N 143N8334-27 FRAME INTERCOSTAL. ACCOMPLISHED GIRT BAR PROX SWITCH, OPS CHECKED GOOD.SDR UALA2009011900199Fitting · corrodedRT MLG WHEEL WELL AFT INBOARD BULKHEAD AREA KEEL BEAM BATHTUB FITTING IS CORRODED STA 1180, RBL 2. FABRICATED & INSTALLED NEW FITTING.SDR UALA2009011900198Cable · out of adjustR-1 DOOR EMERGENCY POWER ACTUATION CABLE FAILED PULL CHECK. ADJUSTED CABLE TRIGGER, ONE TURN COUNTER CLOCK WISE, INSTALLED SPRING CLIP LOCK. OPS CHECKS GOOD.SDR UALA2009011500165Frame · dentedAFT PIT FRAME STA 1420, DENT IN FRAME LT SIDE IN SLANT PANEL AREA. MAJOR REPAIR ACCOMPLISHED: CUT OUT DAMAGED SECTION OF FRAME & INSTALLED DOUBLER REPAIR.SDR UALA2009011500164Frame · dentedAFT PIT FRAME STA 1360, DENT IN FRAME, LT SIDE SLANT PANEL AREA. MAJOR REPAIR ACCOMPLISHED: CUT OUT DAMAGED SECTION OF FRAME AND INSTALLED DOUBLER REPAIR.SDR UALA2009011500163Frame · dentedAFT PIT FRAME STA 1440, DENT IN FRAME LT SIDE IN SLANT PANEL AREA. MAJOR REPAIR ACCOMPLISHED: CUT OUT DAMAGED SECTION OF FRAME & INSTALLED DOUBLER REPAIR.SDR UALA2009011500162Frame · dentedAFT PIT FRAME STA 1460, DENT IN FRAME LT SIDE IN SLANT PANEL AREA. MAJOR REPAIR ACCOMPLISHED: CUT OUT DAMAGED SECTION OF FRAME AND INSTALLED DOUBLER REPAIR.SDR UALA2009011400157Annunciator · failedLEFT ENG BOTTLE DISCHARGE ANNUNCIATOR ON P8 PNL FAILED TO ILLUMINATE DURING BOTTLE DISCHARGE TEST. INSTALLED NEW LT ENG BOTTLE DISCHARGE ANNUNCIATOR ON P8 PNL, OPS CHECKS GOOD.SDR UALA2009011400156Frame · dentedAFT PIT FRAME STA 1340, DENT IN FRAME RT SIDE IN SLANT PANEL AREA. MAJOR REPAIR ACCOMPLISHED: CUT OUT DAMAGED SECTION OF FRAME AND INSTALLED DOUBLER REPAIR.SDR UALA2009011200113Frame · dentedAFT PIT FRAME STA 1480, DENT IN FRAME LT SIDE IN SLANT PANEL AREA. MAJOR REPAIR ACCOMPLISHED: CUTOUT DAMAGE AND INSTALLED DOUBLER REPAIR BETWEEN STR 25 AND 27L.SDR UALA2009011200109Frame · dentedAFT PIT FRAME STA 1400, DENT IN LT SIDE FRAME IN SLANT PANEL AREA. MAJOR REPAIR ACCOMPLISHED: CUTOUT DAMAGED SECTION OF FRAME AND INSTALLED DOUBLER REPAIR.SDR UALA2009011200108Skin · damagedAFT CARGO DOOR, LWR AFT CORNER HAS 3-8TH INCH CRACK, HAS STOP DRILL, BUT HOLE DOES NOT GO THROUGH ENTIRE THICKNESS OF SKIN. MAJOR REPAIR ACCOMPLISHED: CUTOUT DAMAGE AND INSTALLED DOUBLER REPAIR.SDR UALA2009011200107Collar · brokenL2 MED BODY TORQUE TUBE LOCKING COLLAR BROKEN. INSTALLED NEW HOLD-OPEN COLLAR.SDR UALA2008123007037Skin · delaminatedRT ELEVATOR LOWER CENTER EXT SURFACE HAS DELAMINATED BROKEN AREA AT ELEV STA 220. REMOVED DAMAGE AND ACCOMPLISHED CARBON FIBER REPAIR.SDR UALA2008122406994Structure · damagedMAJOR REPAIR: L2 DOOR REQUIRES REPAIR DOUBLER AT UPPER HINGE CUTOUT. PERFORMED HFEC PER NDT 6-5 1-00-19 ON UPPER HINGE CUTOUT AND FOUND NO CRACKS NOTED AT THIS TIME AS DOCUMENTED ON NON ROUTINE 25463 BY INSP QC077. THIS REPAIR WILL BE ACCOMPLISHED AS A PREVSDR UALA2008122406993Structure · damagedR2 DOOR REQUIRES REPAIR DOUBLER AT UPPER HINGE CUTOUT. PERFORMED HFEC INSPECTION PER NDT MANUAL 6-51-00-19 ON UPPER HINGE CUTOUT, AND FOUND NO CRACKS NOTED AT THIS TIME AS DOCUMENTED ON NON ROUTINE 25462 BY IN SP QC077. THIS REPAIR WILL BE ACCOMPLISHED AS PRSDR 2008UALA04142Unknown · odorSTRONG ELECTRICAL ODOR FROM MID CABIN. FLIGHT DIVERTED. *S/D* NO FAULT FOUND.SDR 2007UALA03952Oxygen Bottle · reads lowTHE O2 BOTTLE AT SEAT 15A IS LOW.SDR 2007UALA02308Blade · failedNR 1 ENG EGT EXCEEDED 645 DEGREES, NOT DURING SURGE. PEAK EGT WAS 659. CREW COMMENTS: MAX TO IN DEN 10 SEC EXCEEDANCE. [08-08-07] ACCOMPLISHED BOROSCOPE INSPECTION. NR 1 ENGINE FAILED BORO; FOUND 1 EA BLADE HAVING SULFIDATION WITH PARENT METAL CRACK. SDR 2007UALA01257Wire Harness · defectiveEEL FLOOR LIGHTS INOP FROM SEAT 24 TO 32. REPLACED CABLE ASSY. OPS CHECKED GOOD.SDR 2006UALA01009Light · inoperativeTHE FOLLOWING EMERGENCY LIGHTS ARE INOP, 4 L OVER DOOR EXIT SIGN, AFT GALLEY CEILING EXIT SIGN, SLIDE LIGHT DOOR 4L, EXIT SIGN OVER DOOR 2L, EXIT MARKERS DOOR 4L, 4R, 2L, 2R, SLIDE LIGHT DOOR 2L, AISLE LIGHTS ROWS 4, 29, 32, EXIT SIGN AT ROW 9.SDR 2006UALA00699Skin · damagedFOUND DAMAGED SKIN AT FASTENER, LOCATION IS APPROX 9 INCHES ABOVE FWD END OF RAIN GUTTER ABOVE DOOR 2L. DAMAGE CUT OUT AND REPAIRED PER EVA UA-EVA-60232, 8100-9 PROVIDED BY BOEING, 12 MONTH DTA INFORMATION TO FOLLOW.SDR 2003UALA00070Skin · dentedLH EXTERNAL FUSELAGE SKIN HAS DENT 6" AFT OF CABIN PRESSURE STATIC PORT BETWEEN STRINGER 22L-23L, STA. 1370. MAJOR REPAIR ACCOMPLISHED. DOUBLER REPAIR INSTALLED.SDR 2003UALA00064Floorbeam · crackedFLOORBEAM CRACKED AT FLOOR SUPPORT ATTACH CLIP, STA 700 LBL 46. MAJOR REPAIR ACCOMPLISHED. INSTALLED T-CAP REPAIR.SDR 2003UALA00060Skin · dentedSHARP DENT FOUND ON SKIN REPAIR DOUBLER BETWEEN BS600 AND 620 AND STR 16L AND 17L; MORE DENTS BETWEEN BS600 AND 660, STR 14L AND 19L. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER SKIN.SDR 2003UALA00057Floorbeam · crackedSTATION 660, LBL 46, FLOORBEAM IS CRACKED AT FLOOR SUPPORT ATTACH CLIP. MAJOR REPAIR ACCOMPLISHED AT FLOOR BEAM UPPER CAP. PERFORMED SPLICE REPAIR.SDR 2003UALA00056Floorbeam · corrodedSTATION 680, CABIN FLOORBEAM UPPER CAP CORRODED. MAJOR REPAIR ACCOMPLISHED. UPPER FLANGE REPAIRED WITH DOUBLER.SDR 2003UALA00048Floorbeam · corrodedCABIN FLOOR BEAM UPPER CHORD HAS INTERGRANULAR CORROSION BODY STATION 310, RBL 40-45. MAJOR REPAIR ACCOMPLISHED. REPLACED FLOORBEAM UPPER CAP.SDR 2003UALA00039Floorbeam · corrodedSTATION 1640 RBL 58 FLOORBEAM UPPER CAP CORRODED. MAJOR REPAIR ACCOMPLISHED. REPAIR T CAP INSTALLED.SDR 2003UALA00017Web · corrodedCABIN FLOOR STRUCTURE AT STATION 998 TO 1002 LBL 67 AT STRINGER 17L CREASE BEAM WEB CORRODED ON UPPER SURFACE. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED.INSTALLED NEW WEB.SDR 2003UALA00016Plate · corrodedSTATION 1680 TO 1684, RBL44 TO RBL54.5, AFT DECK PLATE CORRODED. MAJOR REPAIR ACCOMPLISHED. INSTALLED REPAIR DOUBLER.
Back to N501UA, cancelled May 11, 2015