N573SC, cancelled Dec 8, 1999
Service difficulty reports · 61
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N573SC' AND deregistration_id = 'N573SC-1999-12-08' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N573SC' AND deregistration_id = 'N573SC-1999-12-08' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SCNA97280Smoke Detector · dirtyTHE NUMBER 8 LAVATORY SMOKE DETECTOR CHIRPS AND WILL NOT RESET. CLEANED DUST FROM SMOKE DETECTOR AND UNIT OPS CHECKED GOOD.SDR SCNA97270Wire · brokenA TEN FOOT LENGTH OF PATH LIGHTING, BETWEEN DOORS L-2 AND L-3, WAS FOUND TO BE INOPERATIVE. FOUND BROKEN WIRING IN TWO PLACES. REPAIRED WIRING, PATH LIGHTING SYSTEM TESTED GOOD.SDR SCNA97083Bulb · failedNR 2 SMOKE DETECTOR LIGHT DID NOT TEST. RELAMPED SMOKE DETECTOR AND FUNCTIONALLY TESTED GOOD.SDR SCNA97071Light · inoperativeFOUND RIGHT AFT SECTION OF AFT CABIN FLOOR EMERGENCY TRACK LIGHTS FLASHING ON AND OFF. REMOVED AND REPLACED ALL FLOOR TRACK LIGHTING ASSOCIATED WITH THE EMERGENCY POWER SUPPLY FOR THE RIGHT AFT SECTION OF THE AFT CABIN. SYSTEM OPS CHECKS NORMAL IN ACCORDANCESDR SCNA97055Test Switch · inoperativeR1 DOOR SLIDE BOTTLE CHARGE TEST LIGHT WAS FOUND INOP. REPLACED TEST SWITCH IN ACCORDANCE WITH 25-61-03 AND REPAIRED BROKEN WIRE, OPS CHECKED GOOD.SDR SCNA97056Battery Pack · dischargedLEFT MID CABIN FLOOR EMERGENCY TRACK LIGHTING, INOP. REMOVED AND REPLACED LEFT HAND MID CABIN FLOOR TRACK LIGHTING. BATTERY PACK AND OPS CHECKED GOOD.SDR SCNA97038Lamp · failedFOUND RANDOM EMERGENCY FLOOR TRACK LIGHTS BURNED OUT UNDER THE FLOOR EXIT PLACARDS NEAR R1, R2, R4, L2 AND L4 DOORS. REMOVED AND REPLACED LAMPS.SDR SCNA97037Wire · brokenFOUND EMERGENCY FLOOR TRACK LIGHTING INOP IN FORWARD CABIN, FIRST ZONE ON LEFT SIDE. REPAIRED BROKEN WIRE AT L1 DOOR AND SYSTEM OPS CHECKED GOOD.SDR SCNA97016Battery Pack · dischargedFOUND LEFT SIDE EMERGENCY FLOOR TRACK LIGHTING INOP AT MID CABIN. REPLACED POWER SUPPLY IN ACCORDANCE WITH MM 33-51-01 AND OPS CHECKED NORMAL.SDR SCNA96450Battery Pack · dischargedFOUND EMERGENCY FLOOR TRACK LIGHT IN MID CABIN RIGHT SIDE INOP. REMOVED AND REPLACED BATTERY PACK AND OPS CHECKED GOOD.SDR SCNA96424Prox Elec Unit · failedALL THREE GEAR UNSAFE LIGHTS ILLUMINATED AFTER GEAR RETRACTION. REPOSITIONSED WIRE BUNDLE INTERFERING WITH HANDLE INTERLOCK SWITCH, REMOVED AND REPLACED PROXIMITY ELECTRONICS UNIT AND RELAY R2-5083. PERFORMED SYSTEM TEST IN ACCORDANCE WITH MM 32-60-00.SDR SCNA96423Pump · failedINFLIGHT, SMOKE WAS REPORTED IN AFT LAV, DISCHARGED TWO FIRE EXTINGUISHERS. DIVERTED TO MSP AND DUMPED FUEL. REMOVED AND REPLACED AFT LAV PUMP AND OPS CHECKED NORMAL.SDR SCNA96324Lamp · inopNO INDICATION OF GREEN ON LEFT MAIN GEAR. VISUALLY CONFIRMED GEAR WAS DOWN AND LOCKED, AND PULLED EMERGENCY EXTENSION. FOUND BULB BURNT OUT. REMOVED AND REPLACED.SDR SCNA96323Power Supply · inoperativeFOUND RIGHT FORWARD EMERGENCY FLOOR LIGHTS INOP. REMOVED AND REPLACED BATTERY PACK POWER SUPPLY AND OPS CHECKED GOOD.SDR SCNA96321Smoke Detector · inoperativeNUMBER 1 CARGO SMOKE DETECTOR DOES NOT TEST. REPLACED BEACON LAMP IN SMOKE DETECTOR AND OPS CHECKED GOOD.SDR SCNA96259Power Supply · inoperativeOVERWING EMERGENCY LIGHT FAILED TEST. REMOVED AND REPLACED OVERWING EMERGENCY POWER SUPPLY IN ACCORDANCE WITH MM 33-51-01 AND OPS CHECKED GOOD.SDR SCNA96250Track · inoperativeEMERGENCY FLOOR TRACK LIGHTING IN FORWARD CABIN, RIGHT SIDE FROM SEAT 5 TO SEAT 11, LIGHT INOP. FOUND DAMAGED RIBBON WIRE. REPAIRED WIRES, OPS CHECKED NORMALLY IN ACCORDANCE WITH MM 33-50-00.SDR SCNA96246Smoke Detector · inoperativeTHE SECOND LIGHT ON THE SMOKE DETECTOR PANEL WOULD NOT TEST. PLACED SMOKE DETECTOR ON MEL 26-15A.SDR SCNA96231Door Frame · corrodedDURING INSPECTION, FOUND FORWARD CARGO DOOR CUTOUT FRAME AT BS 885.8, FORWARD VERTICAL LEG HAS CORROSION AT APPROXIMATELY LONGERON 42R. REPAIRED ANGLE IN ACCORDANCE WITH SABRE TECH EA DC10-53-003.SDR SCNA96230Lower Rail · corrodedDURING INSPECTION, FOUND CENTER CARGO PIT CUT OUT LOWER RAIL UPPER SURFACE CORRODED AT BS 1709.5. BLENDED OUT CORROSION PER SABRE TECH EA DC10-53-004.SDR SCNA96236Door Jamb · corrodedDURING INSPECTION, FOUND CORROSION ON FORWARD CORNER OF LOWER JAMB IN FORWARD CARGO PIT. BLENDED CORROSION IN ACCORDANCE WITH SABRE TECH EA DC10-53-003.SDR SCNA96235Tee Fitting · corrodedDURING INSPECTION, FOUND FORWARD CARGO COMPARTMENT LOWER AFT CORNER TEE FITTING CORRODED. REMOVED AND REPLACED TEE FITTING IN ACCORDANCE WITH SABRE TECH EA DC10-53-003.SDR SCNA96234Fitting · corrodedDURING INSPECTION, FOUND FORWARD CARGO COMPARTMENT LOWER FORWARD CORNER FITTING CORRODED. REMOVED AND REPLACED FITTING IN ACCORDANCE WITH SABRE TECH EA DC10-53-003.SDR SCNA96233Frame · corrodedDURING INSPECTION, FOUND CENTER CARGO COMPARTMENT LOWER FORWARD FRAME CORRODED. BLENDED OUT CORROSION IN ACCORDANCE WITH SABRE TECH EA DC10-53-004.SDR SCNA96232Tee Fitting · corrodedDURING INSPECTION, FOUND CENTER CARGO PIT FORWARD LOWER CORNER TEE FITTING CORRODED. REPLACED TEE IN ACCORDANCE WITH SABRE TECH EA DC10-53-004.SDR SCNA96212Lamp · inoperativeCARGO SMOKE DETECTOR FAILED TEST ON THE NUMBER 3 POSITION. RELAMPED NUMBER 3 SMOKE DETECTOR AND OPERATIONAL CHECKED NORMAL.SDR SCNA96145Bulb · failedONE EMERGENCY LIGHT BY THE FORWARD LEFT HAND LAV WAS FOUND INOP. PLACED ON MEL. REMOVED AND REPLACED LIGHT BULB IN FLOOR TRACK LIGHT.SDR SCNA96151Oven · smokingWHILE OFF, SMOKE STARTED TO COME OUT OF LATCHING MECHANISM ON OVEN NR 3. CIRCUIT BREAKERS WERE PULLED AND GALLEY POWER WAS TURNED OFF. RESET CIRCUIT BREAKER ON BACK OF OVEN. OPS CHECK NORMAL, NO SIGN OF SMOKE.SDR SCNA96040Detector · faultyTHE RIGHT FORWARD LAVATORY CAUSED A CONTINUOUS AURAL WARNING IN THE GALLEY. REMOVED AND REPLACED SMOKE DETECTOR, OPS CHECKED GOOD.SDR SCNA96029Smoke Detector · failedTHE SMOKE DETECTOR IN LAVATORY NUMBER 8 WAS FOUND TO SOUND INTERMITTENTLY. CLEANED OPTICAL LENS AND DETECTOR, OPS CHECKED GOOD.SDR SCNA96026Track · inoperativeTHE AFT CABIN, LEFT SIDE, REAR HALF OF EMERGENCY PATH LIGHTING WAS FOUND TO BE INOPERATIVE. REPLACED DAMAGED SECTION OF FLOOR TRACK LIGHTING AND FLOOR TRACK LIGHTING OPS CHECKED GOOD.SDR SCNA96019Smoke Detector · failedTHE NUMBER 3 LAVATORY SMOKE DETECTOR SOUNDED CONTINUOUSLY FOR NO APPARENT REASON. REMOVED AND REPLACED NUMBER 3 LAVATORY SMOKE DETECTOR AND DETECTOR TESTED GOOD.SDR SCNA96017Track · failedEMERGENCY TRACK LIGHTING FROM SEATS 11ABC TO 13ABC WAS FOUND TO BE INOPERATIVE. FOUND BROKEN WIRE. REPAIRED WIRE AND LIGHTS OPS CHECKED NORMAL.SDR SCNA96016Interlock Crank · frozenDURING CLIMB HAD TO USE THE OVERRIDE GEAR RELEASE TO RAISE LANDING GEAR. THE MAIN GEAR HYDRAULIC INTERLOCK CYLINDER CRANK WAS FOUND FROZEN WITH ICE IN THE ANTI-RETRACT POSITION. APPLIED HEAT, CRANK OPERATED FREELY AND ANTI-RETRACT BUTTON IS NOT NEEDED TO RAISDR SCNA95293Slide Press Ind · malfunctionedTHE L-2 DOOR SLIDE WOULD NOT TEST. REMOVED AND REPLACED SLIDE PACK PRESSURE INDICATOR IAW MM 25-61-03 AND SLIDE TESTED GOOD.SDR SCNA95276Slide · failedWHEN OPENING THE R-3 DOOR THE SLIDE WAS DEPLOYED INADVERTENTLY AND THE UPPER PORTION OF THE SLIDE FAILED TO INFLATE. REMOVED AND REPLACED THE R-3 DOOR SLIDE.SDR SCNA95274Batteries · dischargedTHE L-3 DOOR SLIDE WOULD NOT TEST. REMOVED AND REPLACED BATTERIES FOR L-3 DOOR SLIDE LIGHT AND SLIDE TESTED GOOD.SDR SCNA95271Smoke Detector · dirtyTHE SMOKE DETECTOR IN THE NUMBER 3 LAV SOUNDED DURING LANDING, NO APPARENT REASON. CLEANED SMOKE DETECTOR AND UNIT PASSED SELF TEST.SDR SCNA95262Smoke Detector · failedTHE NUMBER 8 LAVATORY SMOKE DETECTOR WAS FOUND TO SOUND FOR NO APPARENT REASON. REMOVED AND REPLACED NUMBER 8 LAV SMOKE DETECTOR, NEW DETECTOR OPS CHECKED GOOD.SDR SCNA95210Intercostal · corrodedDURING SCHEDULED INSPECTION, CORROSION WAS FOUND ON THE INTERCOSTAL AT STATION 1505, APPROXIMATELY BS 78. REMOVED AND REPLACED THE INTERCOSTAL AT STATION 1505 IAW SRM 51-33-01.SDR SCNA95209Blkhd Stiffener · corrodedDURING SCHEDULED INSPECTION, CORROSION WAS FOUND ON THE VERTICAL STIFFENER ATTACHED TO THE FORWARD SIDE OF THE STATION 1521 BULKHEAD AT APPROXIMATELY BS 78. THE VERTICAL STIFFENER WAS REPAIRED IAW SUN COUNTRY ENGINEERING ORDER 53-5154-1.SDR SCNA95208Frame · corrodedDURING SCHEDULED INSPECTION, CORROSION WAS FOUND ON THE AFT FACE OF STATION 1505 FRAME LOWER CAP AT APPROXIMATELY BS 78. THE FRAME WAS REPAIRED IAW SUN COUNTRY ENGINEERING ORDER 53-5155-1.SDR SCNA95194Slide · faultyTHE L-3 DOOR SLIDE WOULD NOT TEST. REPLACED THE L-3 DOOR SLIDE IAW MM 25-61-01 AND THE SLIDE TESTED GOOD.SDR SCNA95193Slide Indicator · failedTHE R-3 DOOR SLIDE WOULD NOT TEST. REPLACED THE R-3 DOOR TEST INDICATOR AND SLIDE TESTED GOOD PER MM 25-61-03.SDR SCNA95182Smoke Detector · failedSMOKE DETECTOR IN MID GALLEY CEILING WAS INTERMITTENTLY SOUNDING. REPLACED SMOKE DETECTOR WHICH WAS CAUSING ALARM SOUND, NEW DETECTOR OPS CHECKED GOOD PER MM 26-16-00.SDR SCNA95168Smoke Detector · malfunctionedTHE SMOKE DETECTOR IN LAVATORY NUMBER 8 WENT OFF TWICE FOR NO APPARENT REASON. REMOVED AND REPLACED NUMBER 8 LAV SMOKE DETECTOR AND UNIT TESTED GOOD.SDR SCNA95160Eel Battery Pack · dischargedTHE FORWARD LEFT AND RIGHT EMERGENCY FLOOR LIGHTS ILLUMINATED SHORTLY AFTER TAKEOFF. THE EMERGENCY LIGHTS WERE FOUND SHORTED DUE TO A RIGHT FORWARD LAV LEAKING FLUID. THE EMERGENCY BATTERY PACKS WERE REPLACED AND THE LIGHTS TESTED GOOD.SDR SCNA95154Eel Connector · shortedFOUND THE OVERWING (OVERHEAD) EMERGENCY LIGHTS INTERMITTENT. CONNECTOR PI-2069 WAS FOUND INTERNALLY SHORTING WHEN CONNECTED TO THE EMERGENCY LIGHT BATTERY PACK. REMOVED AND REPLACED CONNECTOR PI-2069 AND LIGHTS CHECKED GOOD.SDR SCNA95153Eel Power Supply · failedDURING LINE CHECK FOUND THE MID CABIN OVERHEAD EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED MID CABIN POWER SUPPLY IAW MM 33-50-00. LIGHTS CHECKED GOOD.SDR SCNA95150Eel Power Supply · failedDURING LINE CHECK, FOUND MID CABIN FLOOR EMERGENCY LIGHTS DIM. REMOVED AND REPLACED MID CABIN POWER SUPPLY IAW MM 33-50-00. LIGHT OPS CHECKED GOOD.
Back to N573SC, cancelled Dec 8, 1999