What was found
DURING INSPECTION, FOUND CENTER CARGO PIT CUT OUT LOWER RAIL UPPER SURFACE CORRODED AT BS 1709.5. BLENDED OUT CORROSION PER SABRE TECH EA DC10-53-004.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND CENTER CARGO PIT CUT OUT LOWER RAIL UPPER SURFACE CORRODED AT BS 1709.5. BLENDED OUT CORROSION PER SABRE TECH EA DC10-53-004.