N614AA, cancelled Mar 8, 2018

Service difficulty reports · 34

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N614AA' AND deregistration_id = 'N614AA-2018-03-08'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR AALA20111222DFW01Light · inoperativeRIGHT AFT OVERWING EXTERIOR EMERGENCY LIGHT INOPERATIVE. REPLACED LAMP FOR RIGHT AFT OVERWING EXTERIOR EMERGENCY LIGHT. OPS CHECK NORMAL.Dec 20, 2011 · N614AA · Boeing 757223 · Emergency LightingSDR AALA20110317DFW01Lens · missingSEAT 9D EMERGENCY ESCAPE PATH LIGHT LENS MISSING. REPLACED LENS FOR SEAT 9D EMERGENCY LIGHT. OPS CHECK NORMALMar 16, 2011 · N614AA · Boeing 757223 · Emergency LightingSDR AALA20100902TUL03Floorbeam · crackedFLOORBEAM AND VERTICAL STIFFENER CRACKED STATION 660 AT LEFT BUTTLINE 48. REPAIRED FLOORBEAM PER AARD 53-30-51-2 AND REPLACED VERTICAL STIFFENERS WITH SERVICEABLE PART PER SRM 51-70-00-0G.Aug 24, 2010 · N614AA · Boeing 757223 · Fuselage Main, Floor BeamSDR AALA20100903TUL04Skin · corrodedCORROSION ON NUMBER 7 SLAT UPPER SKIN AT INBOARD DRIVE TRACK. REMOVED CORROSION AND INSTALLED DOUBLER PER AARD 57-43-00-3.Aug 24, 2010 · N614AA · Boeing 757223 · Leading Edge DevicesSDR AALA20100901TUL01Floorbeam · crackedFLOORBEAM AND VERTICAL STIFFENERS CRACKED AT STATION 700 AND LEFT BUTTLINE 24 AND LEFT BUTTLINE 48. REPAIRED FLOORBEAM PER AARD 53-30-51-2 AND INSTALLED SERVICEABLE STIFFENERS PER SRM 51-10-02-0G.Aug 24, 2010 · N614AA · Boeing 757223 · Fuselage Main, Floor BeamSDR AALA20100830TUL09Skin · damagedFUSELAGE SKIN BAD FASTENER AT STATION 510 AND BETWEEN STRINGER 27 RIGHT TO 28 RIGHT. CUT OUT DAMAGED AREA AND INSTALLED DOUBLER PER SRM 53-00-01-2R.Aug 24, 2010 · N614AA · Boeing 757223 · Fuselage Main, Plate/SkinSDR AALA20100830TUL07Skin · burnedSTATIC BURNS ON FUSELAGE SKIN STATIONS 1660 TO 1720 AND STRINGER 22 RIGHT TO 24 RIGHT. INSTALLED DOUBLER PER SRM 53-00-01-2R.Aug 24, 2010 · N614AA · Boeing 757223 · Fuselage Main, Plate/SkinSDR AALA20090915LGA01Light · inoperativeEMERGENCY LIGHT IN CABIN HAD BURNED OUT LAMP. REPLACED LAMP.Sep 14, 2009 · N614AA · Boeing 757223 · Emergency LightingSDR AALA20090707TUL18Pressure Panel · corrodedPRESSURE DECK CORRODED. REPAIRED IAW EA B757-53-005461.Feb 13, 2009 · N614AA · Boeing 757223 · Fuselage Main, BulkheadSDR AALA2009012400355Battery Pack · dischargedDFW - EMERGENCY LIGHTS FOR SEATS 26 THRU 36 NEAR RIGHT AFT LAVATORY INOPERATIVE. REPLACED BATTERY PACK FOR SEAT 26 THRU 36 NEAR RIGHT AFT LAVATORY.Jan 24, 2009 · N614AA · Boeing 757223 · Emergency LightingSDR AALA2009012400354Battery Pack · dischargedDFW - EMERGENCY LIGHTS FROM SEAT 1E THRU SEAT 6E INOPERATIVE. REPLACED BATTERY PACK FOR SEATS 1E THRU 6E.Jan 24, 2009 · N614AA · Boeing 757223 · Emergency LightingSDR AALA200803085Life Vest · missingDFW - SPARE LIFE VEST KIT MISSING ONE EACH LIFE VEST. REPLACED LIFE VEST. SYSTEM GROUND CHECKED NORMAL OPERATION.Dec 10, 2008 · N614AA · Boeing 757223 · Life JacketSDR AALA200803084Battery Pack · dischargedDFW - EMERGENCY LIGHTS FROM SEAT ROWS 16D TO 26D ARE DIM. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION.Dec 10, 2008 · N614AA · Boeing 757223 · Emergency LightingSDR AALA200803083Placard · damagedDFW - EMERGENCY LIGHT EXIT DECAL IN FRONT OF SEAT 18A IS PEELING OFF. REPLACED DECAL. SYSTEM GROUND CHECKED NORMAL OPERATION.Dec 10, 2008 · N614AA · Boeing 757223 · Placards and MarkingsSDR AALA200800208Water Heater · inoperativeGJT INFLIGHT T119/30JAN EWR TO LAX CREW REPORTED SMOKE IN CABIN. SMOKE DETECTORS IN LAVATORIES WENT OFF. LANDED GJT WITHOUT INCIDENT. REPLACED MID LAVATORY WATER HEATER. SYSTEM GROUND CHECKED NORMAL OPERATION.Jan 30, 2008 · N614AA · Boeing 757223 · Potable Water SystemSDR AALA20060958Light · inoperativeJFK - EMERGENCY LIGHT AT FORWARD LEFT WING INOPERATIVE. RELAMPED EMERGENCY LIGHT AT FORWARD LEFT WING. SYSTEM GROUND CHECKED NORMAL OPERATION.Oct 29, 2006 · N614AA · Boeing 757223 · Emergency LightingSDR AALA20060959Light · inoperativeJFK - EMERGENCY LIGHT AT AFT LEFT DOOR INOPERATIVE. RELAMPED EMERGENCY LIGHT AT AFT LEFT DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION.Oct 29, 2006 · N614AA · Boeing 757223 · Emergency LightingSDR AALA20060769Battery Pack · inoperativeSJU - SEAT PATH EMERGENCY LIGHT FROM ROWS 25DEF TO AFT OF CABIN INOPERATIVE. REPLACED CHARGER AND BATTERY PACK FOR SEAT PATH EMERGENCY LIGHTS FROM ROWS 25DEF TO AFT OF CABIN. SYSTEM GROUND CHECKED NORMAL OPERATION.Oct 2, 2006 · N614AA · Boeing 757223 · Emergency LightingSDR AALA20040993Bottle · failedMIA - L1 DOOR SLIDE PARTIALLY DEPLOYED. SLIDE FELL ONTO JETBRIDGE AND DID NOT OPEN WITH ASSIST BOTTLE DISCHARGE. INSPECTED FORWARD ENTRY DOOR HINGES AND DOOR FRAME. NO DAMAGE NOTED. REINSTALLED DOOR SLIDE ASSEMBLY AND REPLACED L1 DOOR ASSIST BOTTLE. SYSTESep 23, 2004 · N614AA · Boeing 757223 · Escape SlideSDR AALA20030193Wire · disconnectedDFW - DURING OVERNIGHT MAINTENANCE, COCKPIT OVERHEAD EMERGENCY EXIT LIGHT INOPERATIVE. RECONNECTED COCKPIT OVERHEAD EMERGENCY EXIT LIGHT WIRE. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Jan 12, 2003 · N614AA · Boeing 757223 · Light System WiringSDR AALA20021879Circuit Card · faultyKIN - FLT 1735 - EN ROUTE MIA-KIN, AFT CARGO LIGHT ILLUMINATED. CARGO FIRE BOTTLE DISCHARGED AND AFT CARGO FIRE LIGHT WENT OUT AFTER APPROXIMATELY ONE MINUTE. AIRCRAFT LANDED IN KIN WITHOUT INCIDENT. REPLACED FIRE LOGIC CARD, FIRE BOTTLES AND SQUIB. SYSTEMDec 26, 2002 · N614AA · Boeing 757223 · VHF Communications SystemSDR AALA20020823Battery Pack · dischargedSNA - L1 DOOR SLIDE LIGHT INOPERATIVE ON EMERGENCY LIGHT TEST. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Jun 5, 2002 · N614AA · Boeing 757223 · Emergency LightingSDR AALA20020833Battery Pack · dischargedMIA - FOUND L1 DOOR EMERGENCY EXIT SIGN LIGHT INOPERATIVE. REPLACED BATTERY PACK TO L1 DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)May 30, 2002 · N614AA · Boeing 757223 · Emergency LightingSDR AALA20020747Power Supply · dischargedJFK - FOUND LEFT ONE EXTERNAL EMERGENCY LIGHT INOPERATIVE. REPLACED EMERGENCY LIGHT POWER SUPPLY M73D. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)May 22, 2002 · N614AA · Boeing 757223 · Emergency LightingSDR AALA20020584Sign · disconnectedDFW - RIGHT SIDE FORWARD EMERGENCY EXIT SIGN AT ROW 16 INOPERATIVE. UNRAVELED EMERGENCY LIGHT WIRES FROM SIDEWALL AND CONNECTED TO EMERGENCY LIGHT. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)May 1, 2002 · N614AA · Boeing 757223 · Emergency LightingSDR AALA20020583Battery Pack · dischargedDFW - NR 1 LEFT DOOR EMERGENCY SLIDE LIGHT INOPERATIVE. REMOVED AND REPLACED BATTERY PACK FOR NR 1 LEFT DOOR SLIDE. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)May 1, 2002 · N614AA · Boeing 757223 · Emergency LightingSDR AALA20020084Light · inoperativeJFK - DURING OVERNIGHT MAINTENANCE, OVERWING EMERGENCY EXIT LIGHT INOPERATIVE. CLEANED EMERGENCY EXIT LIGHT CONTACTS. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Jan 27, 2002 · N614AA · Boeing 757223 · Emergency LightingSDR AALA20001546Light · inoperativeBOS - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHTS FROM ROW 9 TO 16 INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT SEGMENT. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Sep 14, 2000 · N614AA · Boeing 757223 · Emergency LightingSDR AALA970794Floorbeam · corrodedAFW - CABIN FLOORBEAM STATION 365 HAD CORROSION BEYOND SRM LIMITS. BLENDED, ALODINED, FABRICATED REPAIR STRAPS, PRIMED, FILLED BLEND AREAS, INSTALLED STRAPS WET, PER MRB 757-1132. (M)Apr 4, 1997 · N614AA · Boeing 757223 · Fuselage Main, Floor BeamSDR AALA970793Floorbeam · corrodedAFW - CABIN FLOORBEAM STATION 345 CORRODED BEYOND SRM LIMITS. ALODINED BLEND AREAS, FABRICATED REPAIR STRAP, PRIMED, FILLED BLEND AREAS, INSTALLED STRAP WET. REPAIRED PER MRB 757-1133. (M)Apr 4, 1997 · N614AA · Boeing 757223 · Fuselage Main, Floor BeamSDR AALA970792Floorbeam · corrodedAFW - ACCOMPLISHED SRM REPAIR TO CABIN FLOORBEAM STATION 377. FASTENERS AT END OF SRM REPAIR HAVE LESS THAN 20 EDGE MARGIN. CONTINUE IN SERVICE WITH CONDITION AS IS AS A TIME LIMITED REPAIR ON OR BEFORE OCT 2, 1998. (M)Apr 4, 1997 · N614AA · Boeing 757223 · Fuselage Main, Floor BeamSDR AALA961677Connector · looseSFO - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS BETWEEN PAX SEAT ROWS 4E THROUGH 6E INOPERATIVE. RESECURED LOOSE EMERGENCY FLOOR LIGHT CONNECTOR BY PAX SEAT ROW 4E. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Nov 18, 1996 · N614AA · Boeing 757223 · Emergency LightingSDR AALA952163Skin · gougedAFW - FOUND FUSELAGE SKIN HAS GOUGE BLENDED BEYOND SRM LIMITS AT STATION 580, STRINGER 26R. PER MRG 757-680. (M)Dec 13, 1995 · N614AA · Boeing 757223 · Fuselage Main, Plate/SkinSDR AALA951599Detector · defectiveJFK - FLT NR 1759 - EN ROUTE BOS-JFK - DURING CRUISE, FORWARD EQUIPMENT SMOKE WARNING FOLLOWED BY FORWARD EQUIPMENT OVERHEAT INDICATIONS. ACCOMPLISHED ABNORMAL PROCEDURES AND AIRCRAFT PROCEEDED JFK, LANDING WITHOUT INCIDENT. REPLACED BOTH FORWARD FAN SUPPLY Sep 5, 1995 · N614AA · Boeing 757223 · Smoke Detection
Back to N614AA, cancelled Mar 8, 2018