What was found
AFW - CABIN FLOORBEAM STATION 365 HAD CORROSION BEYOND SRM LIMITS. BLENDED, ALODINED, FABRICATED REPAIR STRAPS, PRIMED, FILLED BLEND AREAS, INSTALLED STRAPS WET, PER MRB 757-1132. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFW - CABIN FLOORBEAM STATION 365 HAD CORROSION BEYOND SRM LIMITS. BLENDED, ALODINED, FABRICATED REPAIR STRAPS, PRIMED, FILLED BLEND AREAS, INSTALLED STRAPS WET, PER MRB 757-1132. (M)