Service difficulty reports · 47
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model.
SDR HALA0100056Gcu · failedFLT 184 - HNL - AIRCRAFT X-TIE LOCKOUT LIGHT CAME ON IN FLIGHT. IT CAUSED A DOUBLE GENERATOR FAILURE, RESET GENERATORS IN FILGHT. APU WAS RESTARTED SUCCESSFULLY. NORMAL LANDING. REPLACED RIGHT GCU. GROUND RAN BOTH ENGINES. OPS CHECK OK. RESET X-TIE LOCKSDR HALA0000240Acm · failedOGG - FLT 112 - SMOKE AND VERY STRONG BURNING SMELL IN CABIN WITH NR 1 LEFT AC PACK ON. OK TO CONTINUE PER MEL 21-1 DMI NR 13681 TRANSCRIBED TO HAL M443 AND MPCW CAT C. REMOVED AND REPLACED NR 1 ACM PER MM 21-51-1. OPS AND LEAK CHECK GOOD. (M)SDR HALA9900195Cotter Key · out of positionFLT 113 - HNL - ON APPROACH TO LIH, WHEN GEAR HANDLE PLACED DOWN, BOTH MAINS CAME DOWN. NOSE GEAR DID NOT COME DOWN. FOLLOWED SOP. RETURNED HNL. GEAR CAME DOWN 3 GREEN. INSPECTED NOSE GEAR COND AND SECURITY CHECK GOOD WIRING CHECK GOOD. REPLACED L/G PROX