N701TW, cancelled Apr 24, 2012

Service difficulty reports · 19

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N701TW' AND deregistration_id = 'N701TW-2012-04-24'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR AALA20060794Bulb · inoperativeSFO - EMERGENCY LIGHT AT SEAT 11D INOPERATIVE. RELAMPED EMERGENCY LIGHT AT SEAT 11D. SYSTEM GROUND CHECKED NORMAL OPERATION.Oct 8, 2006 · N701TW · Boeing 7572Q8 · Emergency LightingSDR AALA20040968End Plug · missingEND PLUG MISSING FOR EMERGENCY ESCAPE PATH LIGHTING TO THE RIGHT OF SEAT 1B AND BEHIND SEAT 24D. INSTALLED END PLUGS FOR EMERGENCY ESCAPE PATH LIGHTING AT SEAT 1B AND BEHIND SEAT 24D. SYSTEM GROUND CHECKED NORMAL OPERATION.Sep 13, 2004 · N701TW · Boeing 7572Q8 · Emergency LightingSDR AALA20040553Power Cable · brokenDFW - EMERGENCY ESCAPE PATH LIGHT AT LEFT HAND AISLE FORWARD OF SEATS 1AB INOPERATIVE. FOUND EMERGENCY LIGHT POWER CABLE BROKEN IN FIRST CLASS. REPLACED EMERGENCY PATH LIGHT POWER CABLE IN FIRST CLASS. SYSTEM GROUND CHECKED NORMAL OPERATION.May 13, 2004 · N701TW · Boeing 7572Q8 · Light System WiringSDR AALA20040365Light · inoperativeDFW - EMERGENCY FLOOR TRACK LIGHTING AT FIRST CLASS ROW ONE INOPERATIVE. REPLACED POWER STRIP FOR EMERGENCY FLOOR TRACK LIGHTING AT FIRST CLASS ROW ONE. SYSTEM GROUND CHECKED NORMAL OPERATION.Mar 19, 2004 · N701TW · Boeing 7572Q8 · Emergency LightingSDR ZW0A0304802Bulb · inoperativeTHE EXTERNAL EMERGENCY LIGHT AT THE LEFT SIDE NUMBER 4 CABIN DOOR WAS INOPERATIVE. REPLACED THE LAMP. CHECK-C 5-27-02 MCI.May 12, 2003 · N701TW · Boeing 7572Q8 · Emergency LightingSDR ZW0A0206903Skin · crackedDURING CHECK-C MAINT ON THE RT PYLON THE FWD INBD SIDE LIGHTNING HOLE ON NUMBER 2 PYLON WAS CRACKED 1/2 INCH LONG. CONFIRMED BY NDT. REPAIRED PER SERVICE BULLETIN 757-54-0037, AND EMLR 73125. --CLOSED--Jun 20, 2002 · N701TW · Boeing 7572Q8 · Nacelle/Pylon, Plate/SkinSDR ZW0A0206902Structure · crackedDURING CHECK-C MAINT ON RT PYLON, THE FWD OTBD SIDE LIGHTNING HOLE ON THE NUMBER 2 PYLON WAS CRACKED ABOUT 1/2 INCH LONG. CONFIRMED BY NDT. REPAIRED PER SERVICE BULLETIN 757-54-0037 AND EMLR 73125. --CLOSED--Jun 20, 2002 · N701TW · Boeing 7572Q8 · Nacelle/Pylon, Main FrameSDR ZW0A0206901Skin · crackedDURING CHECK-C MAINT ON NUMBER 1 PYLON FOUND A 1 7/8 INCH CRACK EXTENDING FROM UPPER FORWARD CORNER OF FORWARD LIGHTNING HOLE IN LT SIDE SKIN OF PYLON. CONFIRMED BY EDDY CURRENT. INSTALLED FORWARD DOUBLER ON OTBD SIDE PER SERVICE BULLETIN 757-54-0037 AND EMLJun 19, 2002 · N701TW · Boeing 7572Q8 · Nacelle/Pylon, Plate/SkinSDR ZW0A0203202Splice · damagedTHE EGRESS LIGHT AT CABIN ROW 12 WAS INOPERATIVE. REPAIRED THE SPLICE AT ROW 12.Mar 18, 2002 · N701TW · Boeing 7572Q8 · Electrical ConnectorsSDR ZW0A0110501Cable · brokenTHE EGRESS LIGHTS AT THE REAR LAVATORY WOULD NOT TEST. REPLACED THE FLEX CABLE.Nov 3, 2001 · N701TW · Boeing 7572Q8 · Light System WiringSDR ZW0A0106102Wire · wornDURING PRE FLIGHT EGRESS LIGHT STRIP NEXT TO LAV C WERE INOP DUE TO WEAR. INSTALLED NEW CABLE.Jul 26, 2001 · N701TW · Boeing 7572Q8 · Light System WiringSDR TWAA0100301Engine · failedIN CRUISE A LOUD BANG WAS HEARD FROM THE LEFT ENGINE AND IT SPOOLED DOWN. MADE AN UNSCHEDULED LANDING AT MSP. THE ENGINE WAS REPLACED. CHECK-C 12-5-00 LAX.Jan 2, 2001 · N701TW · Boeing 7572Q8 · Engine (Turbine/Turboprop)SDR TWAA0014502Wire · shortedTHE EGRESS LIGHTS WERE INOPERATIVE FROM ROW 19 TO THE LT AFT LAV. FOUND JUMPER CABLE SHORTED AND BROKEN. REPLACED CABLE. CHECK-C 7-31-99 LAX.Sep 16, 2000 · N701TW · Boeing 7572Q8 · Light System WiringSDR TWAA0009501Wire · disconnectedDURING ROUTINE INSPECTION, IT WAS NOTED THAT EGRESS FLOOR LIGHTING WAS INOP. SPLICED IN REPLACEMENT JUMPER CABLE. AC06 05-18-00 LAX.Jun 15, 2000 · N701TW · Boeing 7572Q8 · Light System WiringSDR TWAA0002202Light · looseDURING CRUISE, CABIN ATTENDANT FOUND EGRESS LIGHT STRIP DETACHED FROM THE FLOOR. MAINTENANCE RESECURED THE LIGHT STRIP.Feb 7, 2000 · N701TW · Boeing 7572Q8 · Emergency LightingSDR TWAA0001607Rivet · corrodedTHE LEFT WING HAD 48 RIVETS WITH CORROSION REMOVED PER SRM 57-20-01 FIG 101. ONE RIVET REMOVED AND REPLACED AT STRINGER 4 WBL 326, ONE RIVET REMOVED AND REPLACED AT S-5 WBL 333. ONE RIVET REMOVED AND REPLACED AT S-5 WBL 328 PER SRM 51-40-02, PAGE 9. CHECK-CJan 14, 2000 · N701TW · Boeing 7572Q8 · Wing Miscellaneous StructureSDR TWAA0001606Rivet · corrodedTHE RT WING HAD 126 RIVETS WITH CORROSION AT TOP WING SKIN FROM WBL 300 TO WBL 336, FROM FRONT SPAR TO REAR SPAR. REMOVED CORROSION PER SRM 57-20-01, FIG 106. SEVEN FASTENERS REPLACED PER SRM 51-40-02, PAGE 9 AT STRINGER 2, WBL 317, WBL 308, AFT SPAR AFT ROWJan 4, 2000 · N701TW · Boeing 7572Q8 · Wing Miscellaneous StructureSDR TWAA9915401Fuse · blownTHE RIGHT SIDE NUMBER 1 CABIN DOOR SLIDE LIGHT WAS INOPERATIVE. REPLACED FUSE AND IT BLEW AGAIN. REPOSITIONED THE LIGHT ASSEMBLY AND INSULATED THE CENTER BULB WIRE CONTACT, THEN REPLACED THE FUSE AGAIN. CHECK-C 7-31-99 LAX.Nov 9, 1999 · N701TW · Boeing 7572Q8 · Emergency LightingSDR TWAA9802204Oven · dirtyJFK - FLT 31 - THREE GALLEY OVENS EMITTED SMOKE WHEN DOOR OPENED AFTER USE. POSITIONS WERE A GALLEY NR 1 AND NR 2 OVENS, AND B-GALLEY NR 2 OVEN. BELIEVED CAUSED BY CLEANING SOLVENTS. REPLACED THE A-GALLEY NR 1 AND NR 2 OVENS, DEACTIVATED AND DEFERRED THE B-Feb 12, 1998 · N701TW · Boeing 7572Q8 · Buffet/Galleys
Back to N701TW, cancelled Apr 24, 2012