N70524, cancelled Jan 7, 2019

Service difficulty reports · 54

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N70524' AND deregistration_id = 'N70524-2019-01-07'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR AALA20100225MCI01Apu · contaminatedMCI - FLIGHT ATTENDANT REPORTED ON CLIMBOUT WHOOSHING AT AIR/CYCLING VALVE APPROXIMATELY EVERY 15 SECONDS AT SAME TIME STRONG FUMES AND SMOKE IN CABIN AND COCKPIT. APU WAS SHUTDOWN AND SMOKE INITIALLY CLEARED BUT STARTED BACK UP AGAIN AFTER 1 MINUTE. EMERGENFeb 25, 2010 · N70524 · Doug DC982 · APU Oil SystemSDR AALA2009033000689Battery Pack · dischargedDFW OVERWING EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED BATTERY PACK FOR OVERWING EMERGENCY EXIT LIGHT.Mar 30, 2009 · N70524 · Doug DC982 · Emergency LightingSDR AALA2009031500002Module · inoperativeMSP - FLOOR OVERWING EMERGENCY LIGHTS INOPERATIVE. REPLACED MODULE FOR AISLE EMERGENCY LIGHTS.Mar 15, 2009 · N70524 · Doug DC982 · Emergency LightingSDR AALA2009031500001Module · inoperativeMSP - SEATS 1 TO 21 TRACK LIGHTING INOPERATIVE. REPLACED MODULE FOR AISLE EMERGENCY LIGHTS.Mar 15, 2009 · N70524 · Doug DC982 · Emergency LightingSDR AALA2009031500599Battery Pack · dischargedMSP - OVERHEAD EMERGENCY EXIT LIGHTS AT ROW 7 TO 11 INOPERATIVE. REPLACED BATTERY PACK FOR OVERHEAD EMERGENCY EXIT LIGHTS AT ROW 7 TO 11.Mar 15, 2009 · N70524 · Doug DC982 · Emergency LightingSDR AALA2009031500598Lamp · missingMSP - EMERGENCY LIGHT AT SEAT 13D MISSING LAMP. REPLACED LAMP FOR EMERGENCY LIGHT AT SEAT 13D.Mar 15, 2009 · N70524 · Doug DC982 · Emergency LightingSDR AALA2009031500597Lens · missingMSP EMERGENCY LIGHT AT SEAT 13D MISSING LENS. REPLACED LENS FOR EMERGENCY LIGHT AT SEAT 13D.Mar 15, 2009 · N70524 · Doug DC982 · Emergency LightingSDR AALA2009031500596Battery Pack · dischargedMSP EXTERIOR LEFT AND RIGHT HAND OVERWING EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY LIGHTS AT EXTERIOR LEFT AND RIGHT HAND OVERWING.Mar 15, 2009 · N70524 · Doug DC982 · Emergency LightingSDR AALA2009021000475Battery Pack · dischargedLGA MID CABIN EMERGENCY LIGHTS FROM ROW 20 TO 32 INOPERATIVE. REPLACED BATTERY PACK IN MID CABIN.Feb 10, 2009 · N70524 · Doug DC982 · Emergency LightingSDR AALA2009021000474Battery Pack · dischargedLGA - EMERGENCY LIGHTS FROM ROW 3 TO ROW 19 INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY LIGHTS FOR ROW 3 TO 19.Feb 10, 2009 · N70524 · Doug DC982 · Emergency LightingSDR AALA2009021000473Battery Pack · dischargedLGA - EMERGENCY LIGHT IN FIRST CLASS INOPERATIVE. REPLACED BATTERY PACK IN FIRST CLASS FOR EMERGENCY LIGHT.Feb 10, 2009 · N70524 · Doug DC982 · Emergency LightingSDR AALA200802542Pan · corrodedCORROSION FOUND ON FORWARD CARGO DOOR THRESHOLD PAN. AREA OF DISCREPANCY IS 1 INCH BY 57 INCHES WITH A DEPTH OF .030 INCH. REPLACED LOWER SECTION OF PAN IN ACCORDANCE WITH SRM 53-05-00.Sep 16, 2008 · N70524 · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA200800610Battery Pack · inoperativeLGA - EMERGENCY LIGHT AT OVERWING RIGHT NUMBER TWO DOOR INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY LIGHT AT OVERWING RIGHT NUMBER TWO DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION.Mar 12, 2008 · N70524 · Doug DC982 · Emergency LightingSDR AALA200800599Battery Pack · dischargedLGA - EMERGENCY LIGHT AT RIGHT OVERWING EXIT INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY LIGHT AT RIGHT OVERWING EXIT. SYSTEM GROUND CHECKED NORMAL OPERATION.Mar 11, 2008 · N70524 · Doug DC982 · Emergency LightingSDR AALA20072546Battery · dislodgedLGA - EMERGENCY LIGHTS AT AFT VENTRAL STAIRS SIDE WALL INOPERATIVE. SECURED BATTERY IN CHARGER FOR EMERGENCY LIGHTS AT AFT VENTRAL STAIRS SIDE WALL. SYSTEM GROUND CHECKED NORMAL OPERATION.Dec 29, 2007 · N70524 · Doug DC982 · Emergency LightingSDR AALA20072024Slide · failedMSY - AFT GALLEY SERVICE DOOR SLIDE DISLODGED BY AIRCRAFT CLEANERS. DID NOT DEPLOY. REPLACED AFT GALLEY SERVICE DOOR SLIDE. SYSTEM GROUND CHECKED NORMAL OPERATION.Oct 24, 2007 · N70524 · Doug DC982 · Escape SlideSDR AALA20071809Slide · low pressureTPA - FORWARD GALLEY DOOR SLIDE PRESSURE OUT OF RANGE. REPLACED FORWARD GALLEY DOOR SLIDE. SYSTEM GROUND CHECKED NORMAL OPERATION.Sep 25, 2007 · N70524 · Doug DC982 · Escape SlideSDR AALA20071100Lens · missingTPA - EMERGENCY EXIT LIGHT AFT OF FORWARD GALLEY MISSING LENS. REPLACED EMERGENCY EXIT LIGHT ASSEMBLY AT LOWER AFT OF FORWARD GALLEY. SYSTEM GROUND CHECKED NORMAL OPERATION.Jun 14, 2007 · N70524 · Doug DC982 · Emergency LightingSDR AALA20071094Light · damagedJFK - EMERGENCY EXIT LIGHT AFT OF FORWARD GALLEY DAMAGED. REPLACED EMERGENCY EXIT LIGHT ASSEMBLY AFT OF FORWARD GALLEY. SYSTEM GROUND CHECKED NORMAL OPERATION.Jun 13, 2007 · N70524 · Doug DC982 · Emergency LightingSDR AALA20060793Lens · brokenDFW - EMERGENCY LIGHTS AT SEATS 19D AND 30D HAVE LENS BROKEN. REPLACED LENS FOR EMERGENCY LIGHTS AT SEATS 19D AND 30D. SYSTEM GROUND CHECKED NORMAL OPERATION.Oct 7, 2006 · N70524 · Doug DC982 · Emergency LightingSDR AALA20050617Battery Pack · inoperativeDTW - AFT CEILING EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACK FOR AFT CEILING EMERGENCY LIGHTS. SYSTEM GROUND CHECKED NORMAL OPERATION.Jun 29, 2005 · N70524 · Doug DC982 · Emergency LightingSDR AALA20041188Wire · inoperativeDFW - EMERGENCY EXIT LIGHT ON FORWARD GALLEY AISLE INOPERATIVE. REPLACED THE QUICK DISCONNECT ON THE LIGHT ASSEMBLY WIRING. SYSTEM GROUND CHECKED NORMAL OPERATION.Nov 30, 2004 · N70524 · Doug DC982 · Light System WiringSDR AALA20030900Controller · malfunctionedEN ROUTE MIA-LGA, AT 29,000 FT PACK FLOW GAUGES WENT TO ZERO AND AIRCRAFT LOST ALL PRESSURIZATION. ALL MASK DEPLOYED. AIRCRAFT REMOVED FROM SERVICE AND FERRIED TO DFW. INSPECTED DUCTS IN TAIL COMPARTMENT AND WHEEL WELL. PERFORMED BITE OF CONTROLLERS. UNABAug 22, 2003 · N70524 · Doug DC982 · Cabin Pressure ControllerSDR AALA20020503Clamp · looseBOS-ORD - TAIL COMPARTMENT TEMPERATURE HIGH LIGHT ILLUMINATED APPROXIMATELY 1 MINUTE AFTER TAKEOFF. LIGHT EXTINGUISHED WITHIN 2 MINUTES OF MOVING SWITCHES TO HP BLEED OFF. AIR INTERRUPTED AND LANDED BOS WITHOUT INCIDENT. TIGHTENED LEFT AIR CONDITIONING PRESApr 17, 2002 · N70524 · Doug DC982 · Air Distribution SystemSDR AALA20020313Contactor · dirtyORD - DURING OVERNIGHT MAINTENANCE, BOTH TAIL CONE EMERGENCY EXIT LIGHTS INOPERATIVE. CLEANED TAIL CONE EMERGENCY EXIT LIGHT CONTACTS. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Mar 17, 2002 · N70524 · Doug DC982 · Emergency LightingSDR AALA2002051Door Frame · corrodedTUL - FOUND CORROSION ON AFT CARGO DOOR LOWER BEAM FROM STATION 1160-1193. INSTALLED FULL LENGTH DOUBLER NR 3 AS PER AARD 53-10-00-3. (M)Jan 14, 2002 · N70524 · Doug DC982 · Fuselage Main, StructureSDR AALA2002046Stiffener · corrodedTUL - FOUND CORNER STIFFENER CORRODED ON AFT SIDE OF STATION 1155 FRAME AT FORWARD LOWER CORNER OF CARGO DOOR WAY. REMOVED AND REPLACED CORNER STIFFENER ON AFT SIDE OF STATION 1155 FRAME AT FORWARD LOWER CORNER OF AFT CARGO DOOR WAY AS EPR SRM 53-01-00. (M)Jan 11, 2002 · N70524 · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA2002055Tripler · crackedTUL - FOUND RIGHT MLG W/W CUT OUT, AFT OUTBOARD TRIPLER CRACKED. INSTALLED TRIPLER PER SRM 53-01. (M)Jan 9, 2002 · N70524 · Doug DC982 · Fuselage Main, Plate/SkinSDR AALA2002053Frame · chafedTUL - FOUND LINE RUBBING ON 1431 CANT FRAME RIGHT SIDE INBOARD L15R. BLENDED OUT DAMAGED AREA, DYE CHECKED, FABRICATED AND INSTALLED DOUBLER PER 53-10-00-15. (M)Jan 9, 2002 · N70524 · Doug DC982 · Fuselage Main, FrameSDR AALA20020028Seat Track · corrodedTUL - FOUND CORROSION AROUND FAST HOLE. REMOVED AND REPLACED SEAT TRACK SECTION AT FACTORY BREAKS PER 53-05 FIG 4F SRM. (M)Jan 7, 2002 · N70524 · Doug DC982 · Fuselage, Seat/Cargo Attach FittingsSDR AALA2002045Web · corrodedTUL - FOUND STATION 522 TO 530 RIGHT SIDE OF CARGO CUSP CORRODED AROUND FORWARD LIGHTNING HOLE OF BAY, BOTTOM SIDE OF CUSP. INSTALLED DOUBLER PER AARD 53-00-02. (M)Jan 7, 2002 · N70524 · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA20020027Skin · dentedTUL - FOUND GOUGE ON INNER SURFACE OF FUSELAGE SKIN STATION 260, BETWEEN LONGERON 24 AND LONGERON 25 RIGHT. INSTALLED REPAIR PER SRM 53-04 FIG 38 SHEET 4. (M)Jan 4, 2002 · N70524 · Doug DC982 · Fuselage Main, Plate/SkinSDR AALA20020026Door Frame · dentedTUL - FOUND DENT IN FORWARD CARGO DOOR CUTOUT UPPER CORNER. REPAIRED DENTED AREA PER ESO 80559. (M)Jan 4, 2002 · N70524 · Doug DC982 · Fuselage Main, StructureSDR AALA20020025Web · corrodedTUL - FOUND BOTTOM OF CUSP CORRODED AROUND LIGHTING HOLE. CUT OUT DAMAGE AND INSTALLED DOUBLER REPAIR PER AARD 53. (M)Jan 4, 2002 · N70524 · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA2002050Seat Track · corrodedTUL - FOUND NR 6 SEAT TRACK HAS AREA OF CORROSION TOP SURFACE OF LUGS AND IN CHANNEL STATION 259. REMOVED AND REPLACED CORRODED SECTION OF SEAT TRACK NR 6 FROM STATION 215-265 PER SRM 53-05. (M)Jan 4, 2002 · N70524 · Doug DC982 · Fuselage, Seat/Cargo Attach FittingsSDR AALA2002049Seat Track · corrodedTUL - FOUND CORROSION ON NR 6 SEAT TRACK. REMOVED AND REPLACED CORRODED SECTION OF SEAT TRACK NR 6 FROM STATION 215-265 PER SRM 53-05. (M)Jan 4, 2002 · N70524 · Doug DC982 · Fuselage, Seat/Cargo Attach FittingsSDR AALA20020023Attach Angle · crackedTUL - FOUND TWO HILOCK HEADS DISHED, ATTACH ANGLE CRACKED FROM HOLE TO HOLE PLUS .125 INCH FORWARD. INSTALLED VERTICAL STABILIZER TO FUSELAGE ATTACH ANGLE PER AARD 53-10-00-2. REPLACED 2 DISHED HILOCKS AND LEFT SIDE. (M)Jan 3, 2002 · N70524 · Doug DC982 · Fuselage, Stabilizer Attach FittingsSDR AALA20020024Attach Angle · crackedTUL - FOUND 1 HI-LOCK DISHED, ATTACH ANGLE CRACKED FROM HOLE TO HOLE AND AFT PLUS 6 INCHES. REMOVED AND REPLACED CRACKED HI-LOCK. INSTALLED DOUBLER PER AARD 53-10-00-2 ON RIGHT SIDE. (M)Jan 2, 2002 · N70524 · Doug DC982 · Fuselage, Stabilizer Attach FittingsSDR AALA2002048Web · damagedTUL - FOUND HOLE IN SUBFLOOR UNDER CENTER FLIGHT COMPARTMENT FLOORBOARD, STATION 160 LBL 5 INCHES. CUT OUT DAMAGED AREA AND INSTALLED DOUBLER PER SRM 53-01 FIG 4 SHEET 3. (M)Jan 2, 2002 · N70524 · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA2002044Seat Track · corrodedTUL - FOUND SEAT TRACK NR 3 HAS CORROSION AT STATION 1165 AND 1201. REPLACED NR 3 SEAT TRACK SECTION PER SRM 53-05. (M)Jan 2, 2002 · N70524 · Doug DC982 · Fuselage, Seat/Cargo Attach FittingsSDR AALA2002047Stiffener · corrodedTUL - FOUND CORNER STIFFENER CORRODED ON FORWARD SIDE OF STATION 1212 FRAME AT LOWER AFT CORNER OF CARGO DOORWAY. REMOVED CORROSION BLENDOUT BEYOND MM LIMITS. REMOVED AND REPLACED FITTING PER SRM 51-01. (M)Dec 19, 2001 · N70524 · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA2002052Longeron · crackedTUL - FOUND LONGERON 4 LEFT STATION 160 CRACKED AT BELT FRAME ATTACH HOLES. REMOVED CRACKED LONGERON SECTION AND SPLICE IN NEW SECTION PER SRM 53-02 FIG 18. (M)Dec 18, 2001 · N70524 · Doug DC982 · Fuselage Main, Longeron/StringerSDR AALA20001701Wire · damagedDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT SEAT 22D INOPERATIVE. SPLICED EMERGENCY EXIT LIGHT WIRES AT SIDE WALL. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Oct 13, 2000 · N70524 · Doug DC982 · Light System WiringSDR AALA991813Unknown · odorORD - FLT 1387 - DURING TAXI, ODOR OF OVERHEATED ELECTRICAL CIRCUITS REPORTED. RETURNED TO GATE ORD. ODOR CONTINUED AND MAINTENANCE VERIFIED ODOR. AFTER EXTENSIVE INSPECTION AND CLEANING NO ODORS WERE NOTED. COULD NOT DUPLICATE ODOR. SYSTEM GROUND CHECK NNov 28, 1999 · N70524 · Doug DC982 · Air Distribution SystemSDR AALA990889Clamp · looseDFW - FLT 1233 - AFTER TAKEOFF TAIL COMPARTMENT OVERHEAT LIGHT ILLUMINATED WITH MASTER WARNING. ANTI-ICE WAS OFF. ON THROTTLE BACK, LIGHT EXTINGUISHED, BUT ILLUMINATED AGAIN ON THROTTLE UP. APU WAS OFF AT THE TIME. AIR INTERRUPTED RETURNED TO DFW AND LANDEJun 17, 1999 · N70524 · Doug DC982 · Pneumatic Distribution SystemSDR AALA990679Turbine · seizedDFW - FLT 817 - DURING TAKEOFF, FLT ATTENDANT REPORTED AN UNUSUAL ODOR WITH SMOKE IN THE CABIN. FLIGHT AIR INTERRUPTED, RETURNED DFW AND LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE TROUBLESHOT AND FOUND THE LEFT ACM SEIZED. MAINTENANCE REPLACED LEFT ACM. May 7, 1999 · N70524 · Doug DC982 · Cabin Cooling SystemSDR AALA990255Actuator · defectiveDFW - FLT 2213 - EN ROUTE - ORD-DFW - AFTER TAKEOFF AND RETRACTING GEAR, RED NOSE GEAR LIGHT STAYED ILLUMINATED. ALL OTHER INDICATIONS WERE THAT THE NOSE GEAR WAS RETRACTED. LIGHT STAYED ILLUMINATED UNTIL LEVELING AT 11,000 FEET. ON DESCENT, GOT THREE RED Feb 19, 1999 · N70524 · Doug DC982 · Landing Gear ActuatorSDR AALA990121Sensor · defectiveDFW - FLT 1213 - DURING CLIMB-OUT WITH GEAR RETRACTED, THERE WAS AN INTERMITTENT RED NOSE GEAR LIGHT ILLUMINATING. THERE WAS NO VIBRATION OR AIR NOISE SO FLIGHT CONTINUED TO DFW AND LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE REPLACED UP POSITION PROXIMITY Jan 29, 1999 · N70524 · Doug DC982 · Landing Gear Position and WarningSDR AALA981851Light · inoperativeDTW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHTING AFT OF FIRST CLASS GALLEY INOPERATIVE. REPAIRED EMERGENCY EXIT FLOOR PATH LIGHT STRIP. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Oct 6, 1998 · N70524 · Doug DC982 · Emergency LightingSDR AALA981181Boost Pump · failedRDU - FLT 470 - AFTER LEVEL OFF, EN ROUTE MIA-YUL, AT 33,000 FT THE CENTER FUEL TANK OPERATION BECAME UNRELIABLE. CENTER TANK WOULD FEED SOMETIMES AND WINGS WOULD FEED AT OTHER TIMES. WHEN WING TANK PUMPS WERE TURNED ON, THE INLET FUEL PRESSURE LIGHTS ILLUMIJun 15, 1998 · N70524 · Doug DC982 · Fuel Boost Pump
Back to N70524, cancelled Jan 7, 2019