Service difficulty report · Clamp · Doug DC982

Difficulty date
June 17, 1999
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N70524
Make and model
Doug DC982
Aircraft serial
49916
Part
Clamp
Condition
Loose
Location
Nr 2 Engine
Stage of operation
CL
Nature of condition
J, M
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DFW - FLT 1233 - AFTER TAKEOFF TAIL COMPARTMENT OVERHEAT LIGHT ILLUMINATED WITH MASTER WARNING. ANTI-ICE WAS OFF. ON THROTTLE BACK, LIGHT EXTINGUISHED, BUT ILLUMINATED AGAIN ON THROTTLE UP. APU WAS OFF AT THE TIME. AIR INTERRUPTED RETURNED TO DFW AND LANDED WITHOUT INCIDENT. REPLACED TWO CLAMPS ON RIGHT PRESSURE REGULATOR. INSPECTION OF DUCT AND VALVE FOR CRACKS, CHECKED GOOD. ACCOMPLISHED LEAK AND OPERATIONS CHECK AT ENGINE RUN UP. HAD NO OVERHEAT LIGHT. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)