N7461U, cancelled May 2, 2007
Service difficulty reports · 23
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N7461U' AND deregistration_id = 'N7461U-2007-05-02' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N7461U' AND deregistration_id = 'N7461U-2007-05-02' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2001UALA02077Battery Pack · dischargedRT FORWARD AND REAR OVERWING EMERGENCY EXIT LIGHTS ARE INOPERABLE. REPLACED BATTERY PACK. OPERATIONS CHECK NORMAL.SDR 2001UALA01443Skin · delaminatedFLIGHT SPOILER LEFT WING NR 3 DELAMINATED NEAR TRAILING EDGE. FLT SPOILER LEFT WING NR 3 DELAMINATED NEAR TRAILING EDGE. SPOILER PANEL WAS CHECKED FOR CRACKS OR SCRATCHES AND NONE WERE NOTED. AN INTERIM REPAIR WAS ACCOMPLISHED WITH THE REQUIREMENT THAT THE SSDR 2001UALA00311Controller · malfunctionedFLIGHT RETURNED TO LAS WITH NR 2 LEADING EDGE FLAP PROBLEM. FLAP WOULD NOT RETRACT. SUPPLEMENTAL DATA UPDATE ADJUSTED NR 2 LEADING EDGE FLAP LINKAGE AND CYCLED FLAPS SEVERAL TIMES. CHECKS NORMAL.SDR 2001UALA00102B-Nut · leakingTHE AIRCRAFT EXPERIENCED A SYSTEM A-HYDRAULIC FLUID LOSS DURING CRUISE. AIRCRAFT DIVERTED TO CLE. *S/D* FOUND LOOSE B-NUT ON ELEVATOR FEEL COMPUTER FILTER HOUSING LINE. TIGHTENED APPROX 1 FULL TURN. STATIC LEAK STOPPED. SERVICED A-HYD SYSTEM TO FULL. RASDR 2001UALA00097Rib · crackedNR 4 SLAT OUTBOARD SIDE OF ACTUATOR ROD END ATTACH POINT INTERNAL WEB CRACKED. *S/D* REPAIRED RIB IN ACCORDANCE WITH OVERHAUL MANUAL.SDR 2001UALA00038Shaft · failedAIRCRAFT RETURNED TO DEN DUE TO A SPLIT FLAP CONDITION. *S/D* FOUND LEFT INBOARD FLAP, INBOARD JACKSCREW HAD PIN ON END OF JACKSCREW BROKEN. INSTALLED NEW SHAFT ON AFT END OF JACKSCREW. OPERATIONS CHECK NORMAL.SDR 2000UALA00720Handle · out of adjPREVIOUS CREW REPORTED FORWARD ENTRY DOOR HANDLE POPPED UP ON LANDING. FORWARD ENTRY LIGHT ANNUCIATOR ILLUMINATED AND RUSH OF AIR HEARD BY FLIGHT ATTENDANT. SUPPLEMENTAL DATA UPDATE CORRECTED NOSE NUMBER FROM 7251 TO 7261.MAINTENANCE INFO: ACCOMPLISHED DOOR FSDR 2000UALA00070Rod · brokenLIGHT SMOKE IN CABIN. MAINTENANCE NOTICED SPARKS FROM FLOW MULTIPLIER. *S/D* BROKEN SUPPORT ROD CAUSED FAILURE OF FLOW MULTIPLIER, UNIT SEIZED. REPLACED FLOW MULTIPLIER AND ROD.SDR 99UAL900026Actuator · failedON EXTENSION OF FLAPS NR 5 KRUEGER FLAP DID NOT EXTEND. AMBER LIGHT ON FORWARD PANEL REMAINED ON. SECOND OFFICERS PANEL INDICATED NO EXTENSION. YAW WAS PRESENT IN CONTROLS. MISSED APPROACH WAS ACCOMPLISHED. *S/D* REPLACED LEADING EDGE FLAP ACTUATOR, SYSTSDR 98UAL900550Switch · failedIN CLIMB, LEADING EDGE AMBER LIGHT ILLUMINATED WITH FLAPS IN RETRACTED POSITION. TEST INDICATED NR 2 LEADING EDGE KRUGER FLAP IN TRANSIT LIGHT ON. RETURNED TO ORD. CHECKED OPERATION SEVERAL TIMES. NO DEFECT OF LIGHTS PROBLEMS FOUND. SUSPECT POSSIBLE ICE ASDR 98UAL900298Hose · leakingRETURNED TO GATE DUE TO LOSS OF HYDRAULIC QUANTITY. FOUND HYDRAULIC PRESSURE LINE TO RUDDER PCU LEAKING. REMOVED AND REPLACED LINE. ALSO, LEAK CHECKED OK.SDR 98UAL900188Sign · inoperativeCENTER EMERGENCY EXIT SIGN LIGHTS INOPERATIVE.SDR 97UAL900368Battery · dischargedAFT OVER HEAD EMERGENCY EXIT SIGN AT AFT GALLEY IS FLASHING. BATTERY PACK FOR AFT AISLE EXIT SIGN DISCHARGED. BATTERY MODULE REPLACED.SDR 96UAL900765Wire · brokenMAIN CABIN CEILING LIGHT OVERWING EXIT INOPERATIVE. *S/D* THE WIRES WERE BROKEN. THE WIRES WERE REPAIRED AT THE CONNECTOR-TO-CEILING MOUNTED LIGHT ASSEMBLY AT THE OVERWING EXIT, OPERATIONS CHECK NORMAL.SDR 96UAL900692Wire · openON CLIMB-OUT 12-15 DEGREES NOSE UP AND 220 KNOTS, GOT A HARD KICK TO THE RIGHT (ABOUT SIX DEGREE HEADING CHANGE). RUDDER POSITION INDICATORS SPLIT, CREW REPORTED LOWER RUDDER TO THE RIGHT. AIRCRAFT HAD PREVIOUS REPORTS OF YAW DAMPER PROBLEMS. FOUND W323-006SDR 96UAL900506Engine · malfunctionedAIRFRAME VIBRATION ON CLIMB-OUT AND CRUISE. CAN DUPLICATE VIBRATION BY ROLLING TO THE LEFT. CAN ELIMINATE VIBRATION BY PUTTING SMALL AMOUNT OF SPOILERS ON. PERFORMED DIAGNOSTIC TEST FLIGHT AND FOUND VIBRATION RELATED TO NR 1 ENGINE. REPLACED ENGINE. BORESSDR 96UAL900405Valve Connector · looseNR 1 CROSSFEED VALVE FAILED OPEN, NR 3 FAILED CLOSED. DIVERTED TO DEN. SUPPLEMENTAL DATA UPDATE: FOUND NR 1 CROSSFEED VALVE CONNECTOR DISCONNECTED. RECONNECTED AND OPENED NR 3 CROSSFEED VALVE PER DF794.SDR 96UAL900396Pwr Supply · inoperativeEMERGENCY FLOOR LIGHTING STRIP FROM ROW 5 THROUGH ROW 7 REMAINS ON WITH POWER REMOVED FROM AIRCRAFT. *S/D* POWER SUPPLY FOR THE AFFECTED EEL SECTION WOULD NOT RESET FOLLOWING AN EEL LIGHTING TEST. REPLACED POWER SUPPLY, OPERATION NORMAL.SDR 96UAL900128Battery Pack · dischargedFOUND SEVERAL INOPERATIVE EEL STRIP LIGHTS IN MAIN CABIN, INCLUDING BOTH OVERWING EMERGENCY EXITS. REPLACED BATTERY PACK AND GROUND CHECKED NORMAL.SDR 96UAL900063Press Controller · malfunctionedAT 31,000 FT CABIN ALT OBSERVED AT 9,000 FT SWITCHED TO STANDBY AND CABIN CONTINUED TO CLIMB. WENT TO MANUAL AND FLIGHT RETURNED TO DEN. MAINTENANCE REPLACED PRESSURE CONTROLLER.SDR 95UAL900298Battery Pack · dischargedEMERGENCY EXIT LIGHTING INOPERATIVE AT AFT FACE OF FORWARD DROP CEILING. REPLACED BATTERY PACK.SDR 95UAL900247Detector · shortedNR 2 ENGINE FIRE WARNING GROUND FAULT DETECTOR LIGHT ON. DETECTOR ELEMENT WAS REPOSITIONED TO PREVENT CONTACT WITH STRUCTURE. NO FURTHER PROBLEMS REPORTED.SDR 95UAL727031Eel Light · inoperativeLEFT INTERIOR OVERWING EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACK AND POWER SUPPLY.
Back to N7461U, cancelled May 2, 2007