N7506, cancelled Jan 7, 2019
Service difficulty reports · 58
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N7506' AND deregistration_id = 'N7506-2019-01-07' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N7506' AND deregistration_id = 'N7506-2019-01-07' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA20100628TUL07Skin · crackedFUSELAGE SKIN CRACKED AT 1474 CANT FRAME APPROXIMATELY LONGERON 22 LEFT. INSTALLED EXTERNAL DOUBLER ON SKIN AT 1474 CANT FRAME AND LONGERON 22 LEFT PER SRM 53-01-00 FIGURE 2.SDR AALA20090830LGA05Battery Pack · dischargedFLOOR EXIT LIGHT ACROSS FORWARD LAVATORY INOPERATIVE. RECHARGED EMERGENCY LIGHTS BATTERY PACK PER MM, OPS CHECK GOOD.SDR AALA20090830LGA04Battery Pack · dischargedFORWARD HATCHES OVERWING LOWER FLOOR EXIT LIGHTS INOPERATIVE. RECHARGED EMERGENCY LIGHTS BATTERY PACK PER MM, OPS CHECK GOOD.SDR AALA20090830LGA03Battery Pack · dischargedFORWARD GALLEY FLOOR EXIT LIGHTS INOPERATIVE. RECHARGED EMERGENCY LIGHTS BATTERY PACK PER MM, OPS CHECK GOOD.SDR AALA20090830LGA02Battery Pack · not seatedAFT OVERWING HATCHES TOP EXIT LIGHTS INOPERATIVE. RESEATED BATTERY PACK AT BIN 20DEF AFT. AFT OVERHEAD EXIT SIGN OPS CHECKS GOOD.SDR AALA20090830LGA01Battery Pack · dischargedSEAT MOUNTED EMERGENCY ESCAPE PATH INOPERATIVE FROM ROW 3 TO ROW 19. RECHARGED EMERGENCY LIGHTS BATTERY PACK PER MM. OPS CHECK GOOD.SDR AALA20090803DEN01Slide · malfunctionedFORWARD GALLEY DOOR SLIDE, FLIGHT ATTENDANT FAILED TO DISARM SLIDE AND SKYCHEF FAILED TO CHECK TO SEE IF IT WAS DISARMED, SKYCHEF OPENED DOOR AND SLIDE CAME OFF DOOR AND DID NOT DEPLOY. SLIDE REPLACED ON E58 DURING PS CHECK.SDR AALA2009013000405Lens · brokenMSP - EMERGENCY LIGHT LENS AT SEAT 18DEF BROKEN. REPLACED LENS AT SEAT 18DEF.SDR AALA2009032900977Battery · dischargedLGA - MID CABIN FLIGHT ATTENDANT EMERGENCY FLASHLIGHT INOPERATIVE. REPLACED BATTERY FOR MID CABIN EMERGENCY FLASHLIGHT.SDR AALA2009013000401Battery Pack · dischargedMSP - EMERGENCY FLOOD LIGHTS OVER CENTER AREA INOPERATIVE. REPLACED BATTERY PACK.SDR AALA200810546Longeron · crackedSTATION 1260 LONGERON 22L, SPLICE CRACKED AT AFT END. INSTALLED SERVICEABLE LONGERON SPLICE PER SRM 51-02-00.SDR AALA200810545Longeron · corrodedCORROSION ON LONGERON 22L STATION 1286 TO 1295. REPAIRED PER SRM 53-02-00 FIG 18.SDR AALA200810548Cusp Web · corrodedCORROSION ON CUSP STATION 135 TO 155. INSTALLED DOUBLER.SDR AALA200810547Seat Track · corrodedCORROSION ON NUMBER 5 SEAT TRACK STATION 200 TO 205. SPLICED IN NEW SEAT TRACK FROM STATION 200 TO 242 PER SRM 53-05-00.SDR AALA200810544Doubler · corrodedCORROSION ON DOUBLER AT FORWARD SERVICE DOOR STATION 180 TO 200. REMOVED AND REPLACED DOUBLER PER AARD 53-20-00-16.SDR AALA200810543Pan · corrodedCORROSION ON LOWER VERTICAL AND HORIZONTAL PAN LEGS, FORWARD CARGO PAN STATION 370 TO 425. INSTALLED SERVICEABLE DOOR PAN AND SPLICES PER SRM 53-05-00 FIG 44.SDR AALA200810542Structure · corrodedCORROSION ON RIGHT SUBFLOOR STATION 218. REPAIRED PER AARD 53-20-00-16.SDR AALA200810541Cusp Web · crackedRIGHT CUSP CRACKED AT STATION 220. INSTALLED A SERVICEABLE CUSP SHEET FROM STATION 218 TO 237.SDR AALA200810540Intercostal · crackedCRACKS IN INTERCOSTAL AT FASTENER HOLE STATION 1287 TO 1309, AFT CARGO. INSTALLED A SERVICEABLE INTERCOSTAL.SDR AALA200810539Fitting · corrodedCORROSION LOWER AFT CORNER FITTING IN AFT CARGO DOOR CUTOUT STATION 1212. INSTALLED A SERVICEABLE FITTING PER SRM 51-30.SDR AALA200810538Fitting · corrodedCORROSION ON LOWER FORWARD CORNER FITTING IN AFT CARGO DOOR CUTOUT STATION 1155. INSTALLED A SERVICEABLE FITTING PER SRM 51-30.SDR AALA200810537Angle · corrodedCORROSION ON RIGHT CUSP TEE ANGLE STATION 220. INSTALLED A SERVICEABLE TEE ANGLE FROM STATION 180 TO 228 PER SRM 53-05-00.SDR AALA200810536Beam · corrodedCORROSION ON MID CARGO DOOR BEAM STATION 636 TO 693. REPAIRED PER AARD 53-10-00-3.SDR AALA200810534Floorbeam · crackedFLOORBOARD SUPPORT CRACKED UNDER BOARD C-14 STATION 1060. INSTALLED A SERVICEABLE SUPPORT PER SRM 51-01.SDR AALA200810533Cargo Track · corrodedCORROSION ON LEFT TIE DOWN TRACK STATION 1041 TO 1220, AFT CARGO. INSTALLED A SERVICEABLE TIE DOWN TRACK PER SRM 53-01.SDR AALA200810532Cusp Web · corrodedCORROSION ON LEFT CUSP BETWEEN STATION 1250 AND 1304. REPAIRED PER AARD 53-20-00-16.SDR AALA200810531Cusp Web · crackedRIGHT CUSP CRACKED STATION 800. INSTALLED A SERVICEABLE CUSP SHEET PER SRM 51-01.SDR AALA200810529Cargo Track · corrodedCORROSION ON RIGHT TIE DOWN TRACK IN AFT CARGO STATION 1041 TO 1155. INSTALLED SERVICEABLE TIE DOWN TRACK.SDR AALA200810535Beam · corrodedCORROSION ON VERTICAL LEG OF AFT CARGO DOOR BEAM AT STATION 1163. INSTALLED FULL BEAM DOUBLER PER SRM 51-10-3 AND AARD 53-10-00-3.SDR AALA200810528Cusp Web · crackedRIGHT CUSP CRACKED AT STATION 810. REPAIRED PER AARD 53-20-00-16.SDR AALA200810527Longeron · crackedLONGERON 2L CRACKED AT STATION 160. REPAIRED LONGERON 2L FROM 148 TO 168 PER SRM 53-02-00 FIG 18.SDR AALA200810526Floorbeam · crackedVERTICAL FLOORBEAM SUPPORT CRACKED STATION 927 UNDER SEAT TRACK NUMBER 2. INSTALLED A SERVICABLE SUPPORT.SDR AALA200810525Mount · corrodedFORWARD GALLEY INBOARD MOUNT CORRODED STATION 160. INSTALLED A SERVICABLE MOUNT.SDR AALA200810524Mount · corrodedFORWARD GALLEY OUTBOARD MOUNT CORRODED STATION 160. INSTALLED SERVICEABLE MOUNT.SDR AALA200810523Seat Track · corrodedCORROSION ON NUMBER 1 SEAT TRACK STATION 1278. INSTALLED REPAIR PLUG PER SRM 53-05-4A.SDR AALA200810522Support Bracket · crackedVERTICAL FLOORBEAM SUPPORT BRACKET CRACKED STATION 927 UNDER NUMBER 5 SEAT TRACK. INSTALLED A SERVICEABLE SUPPORT BRACKET PER SRM 51-01.SDR AALA10521Angle · crackedVERTICAL ANGLE CRACKED BELOW LONGERON 1 STATION 1338. REPAIRED PER AARD 53-10-00-15.SDR AALA200810530Attach Angle · crackedATTACH ANGLE CRACKED BELOW RIGHT HAND TIE DOWN TRACK STATION 237 FORWARD CARGO. INSTALLED SERVICEABLE ANGLE.SDR AALA20072559Battery Pack · inoperativeLGA - EMERGENCY LIGHTS AT FORWARD GALLEY INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY LIGHTS AT FORWARD GALLEY. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20070028Valve · inoperativeIAD INFLIGHT T1507/05JAN DEC TO DFW - DURING CLIMB, THE LEFT FUEL TEMPERATURE ROSE AT 120 DEGREES THE OIL TEMPERATURE ROSE TO 150 DEGREES AND WAS IN THE YELLOW BAND FOR APPROXIMATELY 10 MINUTES. PULLED LEFT FUEL HEAT TIMER K29. OIL TEMPERATURE WENT BELOW THESDR AALA20041260Battery Pack · dischargedSTL - RIGHT AND LEFT OVERWING EMERGENCY EXIT LIGHTS INOPERATIVE. REPLACED BATTERY PACK FOR RIGHT AND LEFT OVERWING EMERGENCY EXIT LIGHTS. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20040642Battery Pack · inoperativeDFW - EMERGENCY LIGHTS IN TAIL CONE ARE INOPERATIVE. REPLACED BATTERY AND CHARGER ASSEMBLY FOR EMERGENCY LIGHTS IN TAIL CONE. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20021605Battery Pack · dischargedPHX - DURING OVERNIGHT MAINTENANCE, EMERGENCY LIGHTS AT SEATS 24-26 INOPERATIVE. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20021348Battery Pack · dischargedDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHTS IN CEILING AT ROWS 3-7 INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT BATTERY PACK IN CEILING AT ROWS 3-7. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20012145Light · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, AFT ACCESSORY OVERHEAD EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20010858Battery Pack · dischargedDFW - DURING OVERNIGHT MAINTENANCE, CEILING MOUNTED EMERGENCY EXIT LIGHT AT ROW 13 THROUGH 17 DIM. REPLACED CEILING MOUNTED EMERGENCY EXIT LIGHT BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20010578Lamp · malfunctionedDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT SEAT 20D DIM. REPLACED EMERGENCY EXIT LIGHT AT SEAT 20D. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20010579Lamp · malfunctionedDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT ILGHT AT SEAT 18D DIM. REPLACED EMERGENCY EXIT LIGHT AT SEAT 18D. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20010580Lamp · malfunctionedDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT SEAT 13D DIM. REPLACED EMERGENCY EXIT LIGHT AT SEAT 13D. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20010581Lamp · malfunctionedDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT SEAT 7D DIM. REPLACED EMERGENCY EXIT LIGHT AT SEAT 7D. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
Back to N7506, cancelled Jan 7, 2019