N7531A, cancelled Sep 9, 2020
Service difficulty reports · 74
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N7531A' AND deregistration_id = 'N7531A-2020-09-09' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N7531A' AND deregistration_id = 'N7531A-2020-09-09' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA20120407012Heater · inoperativeCREW REPORTED RUDDER LIMITER PITOT HEAT CIRCUIT BREAKER TRIPPED. FLIGHT RETURNED TO DEPARTURE AND LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. REPLACED RUDDER LIMITER PITOT TUBE. SYSTEM GROUND CHECKED NORMAL.SDR AALA20111130TUL42Frame · crackedAFT ACCESS TAIL CONE MOUNT CRACKED AT 5:00 ALIGNMENT PIN MKD. STOP DRILLED CRACK AND INSTALLED DOUBLER REPAIR PER SRM 51-30-05 AND EA MD80-53-020473.SDR AALA20111130TUL38Frame · crackedAFT ACCESS TAIL CONE MOUNT CRACKED AT 7:00 ALIGNMENT PIN. STOP DRILLED CRACK AND INSTALLED DOUBLER REPAIR PER SRM 51-30-05 AND EA MD80-53-020473.SDR AALA20111002LGA02Battery Pack · not seatedAFT ACCESSORY COMPARTMENT EMERGENCY OVERHEAD LIGHTS INOPERATIVE. RESEATED BATTERY PACK FOR AFT ACCESSORY COMPARTMENT EMERGENCY LIGHTS. OPS CHECK NORMAL.SDR AALA20111002LGA01Battery Pack · not seatedROWS 13 THRU 16 OVERHEAD EMERGENCY LIGHTS INOPERATIVE. RESEATED BATTERY PACK FOR ROWS 13 THRU 16 OVERHEAD EMERGENCY LIGHTS. OPS CHECK NORMAL.SDR AALA20110518LGA01Battery Pack · dischargedTAIL COMPARTMENT EMERGENCY LIGHTS ABOVE CATWALK ARE INOPERATIVE. REPLACED BATTERY PACK. OPS CHECK NORMAL.SDR AALA20110416TUL01Valve · leakingPHX - CREW REPORTED TAIL COMPARTMENT OVERHEAT INDICATION. EMERGENCY DECLARED FLIGHT RETURNED PHX LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. FOUND AIR LEAK AT RIGHT CROSSFEED VALVE. RETORQUED CLAMP NO LEAKS NOTED. SYSTEM GROUND CHECK NORMAL OPSDR AALA20110218LGA01Battery Pack · dischargedCEILING LIGHTS ROW 16 INOPERATIVE. REPLACED BATTERY PACK, OPS CHECK NORMAL.SDR AALA20100608TUL09Frame · crackedLEFT ANGLE ON AFT SIDE OF STATION 1418 IS CRACKED AT LONGERON 2 RIGHT. INSTALLED FRAME DOUBLER AT STATION 1418 2 RIGHT PER SRM 53-03-00 FIGURE 31A.SDR AALA20100608TUL08Frame · crackedTHE 1418 FRAME CRACKED AT LONGERON 2 RIGHT. INSTALLED FRAME DOUBLER PER SRM 53-03-00 FIGURE 31A.SDR AALA20100608TUL07Longeron · crackedLONGERON 2 RIGHT CRACKED AT FRAME STATION 1418. PERFORMED LONGERON SPLICE PER AARD 53-30-00-2 FIGURE 1.SDR AALA20100607TUL03Attach Fitting · crackedRIGHT SIDE LEADING SLAT CRACKED. LOCATION THE SECOND BRACKET INBOARD FROM OUTERMOST BRACKET. CRACK IS IN THE RADIUS AREA OF OUTBOARD LUG SECOND BRACKET (MARKED). REMOVED 2ND FROM OUTBOARD ATTACH FITTING. LOCATED, DRILLED AND INSTALLED NEW ATTACH FITTING PESDR AALA20100605TUL06Floor Support · damagedCORROSION ON NUMBER 5 SEAT TRACK FLOORBOARD SUPPORT OUTBOARD LEG AT STATION 203. INSTALLED STRAP DOUBLER AND FILLER PER AARD 53-20-22-16.SDR AALA20100605TUL05Angle · damagedCORROSION OUT OF LIMITS ON CUSP TEE STATION 208. INSTALLED NEW CUSP ANGLE REPAIR FROM STATION 180 TO STATION 229 RIGHT SPLICE REPAIR PER SRM 53-05-00.SDR AALA20100605TUL04Cusp Web · damagedCUSP OUT OF LIMITS STATIONS 1155 TO 1174. INSTALLED CUSP REPAIR DOUBLER STATION 1155 TO STATION 1174 PER AARD 53-20-00-16.SDR AALA20100605TUL03Cusp Web · damagedDAMAGE ON RIGHT CUSP OUT OF LIMITS STATIONS 1174 TO 1250. INSTALLED NEW CUSP SHEET FROM STATION 1174 TO STATION 1250 PER AARD 53-20-00-16.SDR AALA20100605TUL02Cusp Web · damagedCORROSION ON RIGHT CUSP STATION 208. INSTALLED DOUBLER REPAIR PER AARD 53-20-00-16.SDR AALA20100604TUL05Track · corrodedCORROSION ON LEFT TIE DOWN STRAP AT STATIONS 1200 TO 1215. INSTALLED TIE DOWN TRACK PER SRM 51-30-01 AND SPLICE PER SRM 51-30-05.SDR AALA20100604TUL03Fitting · corrodedCORROSION ON G-1 GALLEY TIE DOWN FLOOR CENTER FITTING. INSTALLED G-1 GALLEY TIE DOWN FITTING PER SRM 51-30-05.SDR AALA20100604TUL02Cusp Web · corrodedLEFT CUSP STATIONS 850 TO 857 CORROSION OUT OF LIMITS. INSTALLED REPAIR DOUBLER LEFT CUSP STATIONS 846 TO 863 AS PER AARD 53-20-00-16.SDR AALA20100603TUL01Fitting · corrodedHEAVY CORROSION ON G-1 GALLEY FLOOR TIE DOWN OUTBOARD FITTING. REMOVED AND REPLACED G-1 GALLEY FLOOR TIE DOWN FITTING PER SRM 53-04-00 FIGURE 12B.SDR AALA20100603TUL05Attach Angle · crackedRIGHT FUSELAGE TO VERTICAL ATTACH ANGLE HAS CRACK. REPAIR DOUBLER INSTALLED PER AARD 53-10-00-2.SDR AALA20100603TUL03Mount · corrodedREMOVED G-22 MOUNT IN NUMBER 6 SEAT TRACK STATION 217 THAT IS OUT OF LIMITS. INSTALLED G-2 GALLEY MOUNT ON NUMBER 6 SEAT TRACK PER SRM 51-30-02.SDR AALA20100602TUL04Cusp Web · corrodedCABIN LEFT CUSP CORRODED STATIONS 1088 TO 1095. INSTALLED REPAIR DOUBLER ON LEFT CUSP STATIONS 1080 TO 1097 PER AARD 53-20-00-16.SDR AALA20100601TUL07Cusp Web · crackedLEFT CUSP 888 RIVET HOLE CRACKED. INSTALLED REPAIR DOUBLER LEFT CUSP STATION 888 PER AARD 53-20-00-16.SDR AALA20100601TUL04Skin · dentedDENT IN SKIN AT LONGERON 18 LEFT AT STATION 218 AS MARKED. DIMENSIONS ARE 3 INCH BY 3 INCH BY .085 DEPTH. INSTALLED DOUBLER AS PER SRM 53-04-00 FIGURE 12B SHEET 34, CLASS 1 REPAIR.SDR AALA20100601TUL02Rub Strip · wornRIGHT WING NUMBER 3 FLAP VANE INBOARD END RUB STRIP IS WORN THROUGH AT LEADING EDGE. HOT BOND METAL DOUBLER ON RIGHT WING NUMBER 3 FLAP VANE RUB STRIP TRAILING EDGE PER SRM 51-70-02.SDR AALA20100601TUL01Vane · gougedLEFT WING NUMBER 3 FLAP VANE HAS 2 EACH GOUGES IN LEADING EDGE NEAR INBOARD END. INSTALLED HOT BOND DOUBLER ON NUMBER 3 OUTBOARD FLAP INBOARD VANE ASSEMBLY PER SRM 51-70-2.SDR AALA20100531TUL07Cusp Web · damagedRIGHT CUSP DAMAGED AT STATION 830. INSTALLED DOUBLER PER AARD 53-20-00-16.SDR AALA20100531TUL09Fitting · damagedDAMAGE ON G-2 GALLEY AFT TIE DOWN FLOOR FITTING. INSTALLED NEW FITTING PER SRM 51-01-00.SDR AALA20100530TUL01Seat Track · corrodedCORROSION ON SEAT TRACK NUMBER 6 OUT OF LIMITS AT STATION 698. INSTALLED PLUG IN SEAT TRACK NUMBER 6 AT STATION 698 PER SRM 53-10-03.SDR AALA20100528TUL06Skin · dentedDENT IN SKIN AT LONGERON 18 LEFT AT STATION 218. INSTALLED DOUBLER PER SRM 53-04-00 FIGURE 12B SHEET 34 CLASS 1 REPAIR.SDR AALA20100604TUL01Mount · corrodedHEAVY CORROSION ON G1 TIE DOWN FITTING CENTER FITTING. INSTALLED NEW GALLEY NUMBER 1 CENTER MOUNT PER SRM 51-30-05.SDR AALA20091128ORD01Control Valve · stuckCREW REPORTED HIGH TEMPERATURE LIGHT ON FOR TAIL COMPARTMENT. RETURNED TO ORD AND LANDED WITHOUT INCIDENT. REPLACED LEFT FLOW CONTROL VALVE.SDR AALA20090313TUL08Angle · corrodedAFT CARGO DOOR JAMB LOWER CHORD ANGLE CORRODED AT STATION 1170. REMOVED CORROSION, INSTALLED REPAIR DOUBLER OVER CONDITION 4 AREA PER AARD 53-10-00-3.SDR AALA20090313TUL07Frame · crackedFOUR (4) CANT FRAME AT STATION 1480 REPAIR DOUBLER HAS TWO CRACKS. REMOVED CRACKED REPAIR DOUBLER AND INSTALLED INTERIM REPAIR DOUBLER PER ONE TIME ESO 80559 DATED 3/6/09.SDR AALA20090313TUL06Beam · crackedFWD ENTRY DOOR SECOND FROM TOP HORIZONTAL BEAM CRACKED IN RADIUS AT FWD END. INSTALLED DOUBLER PER SRM 52-05-00 FIGURE 31.SDR AALA200802007Csd · inoperativeELP INFLIGHT T1540/31JUL TUS TO DFW. CREW REPORTED LT GENERATOR CLICKED OFF AND ON SEVERAL TIMES. UNABLE TO DISCONNECT CONSTANT SPEED DRIVE. SHUT DOWN NR 1 ENGINE AND LANDED ELP WITHOUT INCIDENT. ENGINE WINDMILL TIME 15 MINUTES. SYSTEM GROUND CHECKED NORSDR AALA200801700Clamp · defectiveORD INFLIGHT T1345/25JUN. CREW REPORTED TAIL COMPARTMENT OVERHEAT INDICATION DURING CLIMB. INDICATION EXTINGUISHED WHEN LT AIR CONDITIONING SWITCH PLACED TO OFF POSITION. RETURNED TO ORD AND LANDED WITHOUT INCIDENT. REPLACED CLAMP AND SHIM AT LT HEAT EXCHASDR AALA200800934Battery Pack · not seatedLGA - EMERGENCY LIGHTS AT OVERHEAD SEAT ROWS 13 TO 16 INOPERATIVE. RESEATED BATTERY PACK FOR EMERGENCY LIGHTS AT OVERHEAD SEAT ROWS 13 TO 16. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA200800935Battery Pack · inoperativeLGA - EMERGENCY LIGHTS AT OVERHEAD TAIL COMPARTMENT CATWALK INOPERATIVE. RESEATED BATTERY PACK FOR EMERGENCY LIGHTS AT OVERHEAD TAIL COMPARTMENT CATWALK. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20071412Light · brokenDFW - EMERGENCY LIGHT AT FORWARD GALLEY WALL BROKEN. REPLACED LIGHT ASSEMBLY FOR EMERGENCY LIGHT AT FORWARD GALLEY WALL. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20071411Light · brokenDFW - EMERGENCY LIGHT MARKER AT RIGHT AFT EXIT BROKEN. REPLACED LIGHT ASSEMBLY FOR EMERGENCY LIGHT MARKER AT RIGHT AFT EXIT. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20060423Light · inoperativeBOS - FORWARD CABIN PORTABLE EMERGENCY LIGHT INOPERATIVE. REPLACED LIGHT ASSEMBLY FOR FORWARD CABIN PORTABLE EMERGENCY LIGHT. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20041143Battery Pack · inoperativeTPA - COCKPIT AND FORWARD AISLE EMERGENCY LIGHT INOPERATIVE. REPLACED BATTERY PACK AT POSITION B523 FOR EMERGENCY LIGHT AT COCKPIT AND FORWARD AISLE. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20031393Battery Pack · dischargedSEA EMERGENCY CEILING LIGHTS AT AFT GALLEY DOOR BACK TO SEATING FROM AFT LAVATORIES INOPERATIVE. REPLACED BATTERY PACK B5-107. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20030825Socket · brokenDURING OVERNIGHT MAINTENANCE, SEAT 13D EMERGENCY LIGHT SOCKET BROKEN. REMOVED AND REPLACED SEAT 13D EMERGENCY LIGHT SOCKET. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20021247Battery · looseDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHTS FROM SEAT 22D THROUGH 26D INOPERATIVE. SECURED EMERGENCY EXIT LIGHTS BATTERY AT SEAT 22-26. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20020961Connector · looseDFW - DURING OVERNIGHT MAINTENANCE, FORWARD LEFT OVERWING EMERGENCY EXIT LIGHT SIGN INOPERATIVE. TIGHTENED WIRE ON CONNECTOR TO FORWARD LEFT OVERWING EMEGENCY EXIT LIGHT SIGN. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20020857Skin · dentedTUL - FOUND DENT AND SCRATCH IN FUSELAGE SKIN LEFT SIDE L26 STATION 162 JUST FORWARD AND BELOW FLAP AIRSTAIR DOOR. INSTALLED DOUBLER PER SRM 53-04 FIG 12B. (M)