N771NC, cancelled May 11, 2015

Service difficulty reports · 43

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N771NC' AND deregistration_id = 'N771NC-2015-05-11'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR DALA1137499862Light · inoperativeMAINTENANCE FOUND ONE EMERGENCY FLOOR PATH LIGHT INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY PER AMM. OPERATIONAL TEST IS NORMAL. AIRCRAFT OK FOR SERVICE.Jun 1, 2011 · N771NC · Doug DC951 · Emergency LightingSDR DALA1105309862Slide · dislodgedTHE SLIDE PACK AT DOOR 1L FELL OUT OF BUSTLE DURING TAKEOFF. MX IN MSP REINSTALLED AND SECURED THE SLIDE.Jan 23, 2011 · N771NC · Doug DC951 · Escape SlideSDR DALA1034909862Web · damagedDURING LINE CHECK, FOUND DAMAGE IN NOSE WHEEL AREA WEB ON LT SIDE DENTED AND SALAD BOWL DAMAGED. TRIMMED OUT DAMAGED WEB TO 1.125" DIA, ACCOMPLISHED HFEC INSP OF CUT OUT AREA, NO DEFECTS NOTED, TREATED & PRIMED, FABRICATED DOUBLER FROM 6AL-4V .040", INSTALLEDDec 6, 2010 · N771NC · Doug DC951 · Fuselage Miscellaneous StructureSDR DALA1022529868Frame · damagedDURING M-CHECK, FOUND 2 EA MISDRILLED HOLES IN AFT ACCY CANTED FRAME AT BS 1275 L3R. REPAIRED IAW SRM 53-02 FIG 18 & SRM 51-30-5.Sep 13, 2010 · N771NC · Doug DC951 · Fuselage Main, FrameSDR DALA1019849862Slide · reads lowDURING LINE CHECK MX FOUND THE L1 DOOR SLIDE AT 0 PSI. DOOR SLIDE L1 WAS REPLACED IAW AMM 25-62-00-201-925A-A.Aug 18, 2010 · N771NC · Doug DC951 · Escape SlideSDR DALA1017529862Valve · leakingAFTER TAKEOFF CLIMBING THROUGH 12K THE NUMBER 1 ENGINE ROLLED BACK SMOOTHLY AND FLAMED OUT. THE FLIGHT CREW DECLARED AN EMERGENCY AND RETURNED TO DTW LANDING WITHOUT INCIDENT. ENGINE NR 1 INLET AND EXHAUST WERE INSPECTED WITH NO DAMAGE FOUND. MAINTENANCE FOJul 25, 2010 · N771NC · Doug DC951 · Fuel Controlling SystemSDR DALA106749862Skin · corrodedDURING L-CHECK FOUND FUSELAGE SKIN CORRODED AT BS 656 L30R-L27L. REPAIRED IAW DWG 9923434 AND AMI CARD 5331-01180-02.Mar 30, 2010 · N771NC · Doug DC951 · Fuselage Main, Plate/SkinSDR DALA106629862Floor Panel · corrodedDURING L-CHECK FOUND CORROSION ON FWD CARGO CTR FLOOR PANEL RIBS NR 1 THRU NR 6. REPAIRED IAW SRM 51-10-4, 51-60-0, 51-30-5, 51-30-1 & DWG 9B53-35812.Mar 29, 2010 · N771NC · Doug DC951 · Fuselage Floor PanelSDR DALA106509862Longeron · corrodedDURING L-CHECK, FOUND CORROSION ON LONGERON 30 END FITTING AT BS 674. REPAIRED IAW SRM 51-10-4 AND 51-10-3.Mar 28, 2010 · N771NC · Doug DC951 · Fuselage Main, Longeron/StringerSDR DALA106529862Floorbeam · crackedDURING L-CHECK FOUND FLOOR SUPPORT AT FLOOR PANEL NR 69 HAS CRACKS AROUND RIVETS. REPAIRED IAW SRM 51-10-4, 51-30-2.Mar 27, 2010 · N771NC · Doug DC951 · Fuselage Main, Floor BeamSDR DALA106519862Floor Panel · damagedDURING L-CHECK FOUND DAMAGE TO CABIN FLOOR PANEL NR 69. REPAIRED IAW SRM 51-30-2 AND SRM 51-30-1.Mar 27, 2010 · N771NC · Doug DC951 · Fuselage Floor PanelSDR DALA106309862Skin · chafedDURING (L) CHECK FOUND RT WING L/E NR 1 SLAT OTBD LOWER SURFACE REPAIR DOUBLER CHAFED. REPAIRED IAW SRM 51-30-8, 51-30-8, 51-30-2.Mar 25, 2010 · N771NC · Doug DC951 · Leading Edge DevicesSDR DALA106299862Longeron Splice · corrodedDURING (H) CHECK FOUND LONGERON SPLICE FITTING CORRODED AT BS 655 L28L. REPAIRED IAW SRM 51-10-4 AND DWG NR 3932849.Mar 25, 2010 · N771NC · Doug DC951 · Fuselage Main, Longeron/StringerSDR DALA106139862Door Frame · crackedDURING L-CHECK FOUND FORWARD DOOR JAMB UPPER CORNER HAS APPROXIMATELY A .1875 INCH CRACK. REPAIRED PER DRAWING SRO 5930117 AND ERA 480134-14AD.Mar 20, 2010 · N771NC · Doug DC951 · Fuselage Main, StructureSDR DALA106129862Frame · chafedDURING L-CHECK FOUND RIGHT FRAME CHAFED AT BS 1326. REPAIRED PER SRM 53-03-04.Mar 20, 2010 · N771NC · Doug DC951 · Fuselage Main, FrameSDR DALA100419862Oil System · overheatedAFTER TAKEOFF THE RT ENGINE OIL QUANTITY INDICATION WENT TO ZERO. OIL TEMPERATURE OF 100 DEGREES AND OIL PRESSURE OF 40 PSI APPEARED NORMAL. THRUST ON THE NR 2 ENGINE WAS REDUCED TO IDLE, WHICH CAUSED THE RT PACK TO AUTO SHUTDOWN. AFTER THROTTLE WAS PULLED Jan 14, 2010 · N771NC · Doug DC951 · Engine Oil Indicating SystemSDR NWAA092609862Wire · brokenDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING FOR THE CATWALK IN THE TAIL COMPARTMENT WAS INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACK AND REPAIRED A BROKEN GROUND WIRE. THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION.Jul 25, 2009 · N771NC · Doug DC951 · Light System WiringSDR NWAA092099862Wire · corrodedDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING FOR THE TAIL COMPARTMENT WAS INOPERATIVE. MAINTENANCE FOUND CORRODED WIRES IN THE LIGHT ASSEMBLY AND REPLACED THOSE WIRES. THE FUNCTIONAL CHECK OF THE SYSTEM WAS SATISFACTORY.Jun 8, 2009 · N771NC · Doug DC951 · Light System WiringSDR NWAA084979862Connector · looseDURING LINE CHECK MX FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN ROWS 14-18 OF THE CABIN WERE INOPERATIVE. MX CORRECTED A LOOSE CONNECTION AND THEN OPS CHECKED THE SYSTEM.Nov 9, 2008 · N771NC · Doug DC951 · Light System WiringSDR NWAA083769862Skin · crackedDURING H-CHECK, FOUND CRACK IN FUSELAGE SKIN AT THE UPPER FORWARD CORNER OF PASSENGER ENTRY DOOR JAMB. REPAIRED PER EA 98-213637. (S)Aug 11, 2008 · N771NC · Doug DC951 · Fuselage Main, Plate/SkinSDR 0400279862Skin · crackedDURING "L" CHECK FOUND CRACK IN FUSELAGE SKIN AT BS 69.55 3.5 INCHES BELOW L14L. REPAIRED IAW EA 98-197450.Jan 29, 2004 · N771NC · Doug DC951 · Fuselage Main, Plate/SkinSDR 0301319862Control Cable · bindingCREW EXPERIENCED SIGNIFICANT BINDING OF THE AILERONS IMMEDIATELY AFTER TAKEOFF. AS AIRSPEED INCREASED, THE CONTROLLABILITY IMPROVED AND LESS FORCE WAS NEEDED TO MOVE THE CONTROL YOKE. FLIGHT RETURNED TO AN UNEVENTFUL LANDING BACK AT DTW. MAINTENANCE CONFJul 16, 2003 · N771NC · Doug DC951 · Aileron Control SystemSDR 0201969862Longeron · corrodedDuring MCK in ATL, Corrosion was found around fastener holes in four places in the base flange of longeron 30 between frame 377 and 389. Repaired per EA 98-189737.May 21, 2002 · N771NC · Doug DC951 · Fuselage Main, StructureSDR 0004269862Battery · looseDURING LINE CHECK, FOUND THE EMERGENCY LIGHTS ABOVE BOTH LEFT AND RIGHT OVERWING EXITS INOPERATIVE. MAINTENANCE RESEATED THE BATTERIES IN THE POWER SUPPLY. OPERATIONAL CHECK NORMAL.Nov 4, 2000 · N771NC · Doug DC951 · Emergency LightingSDR 9810689862Battery · dischargedDURING LINE CHECK, FOUND THE FIRST CLASS SECTION OVERHEAD EMERGENCY LIGHTING INOPERATIVE. MAINTENANCE REPLACED BATTERIES. OPERATIONAL CHECK NORMAL.Sep 14, 1998 · N771NC · Doug DC951 · Emergency LightingSDR 9802149862Epr Transmitter · failedAS TAKEOFF POWER WAS APPLIED, THE LEFT ENGINE WOULD NOT REACH TARGET EPR INDICATION. CREW ABORTED TAKEOFF AND RETURNED TO THE GATE. MAINTENANCE REPLACED THE LEFT ENGINE EPR TRANSMITTER AND INDICATOR, OPERATIONAL CHECK OK.Jan 30, 1998 · N771NC · Doug DC951 · Engine Pressure Ratio (EPR)SDR 9801689862Door · out of adjustMAIN CABIN DOOR COULD NOT BE OPENED FROM THE OUTSIDE. MAINTENANCE REPLACED NYLON WASHERS ON BAYONET ROD, ADJUSTED DOOR ROTATION, AND BAYONET ROD, FUNCTIONAL CHECK OK.Jan 26, 1998 · N771NC · Doug DC951 · Passenger/Crew DoorsSDR 9722259862Battery Pack · dischargedDURING LINE CHECK, FOUND LEFT AND RIGHT OVERWING EMERGENCY EXIT LIGHTS INOPERATIVE. MAINTENANCE REPLACED BATTERY PACKS, OPERATIONAL CHECK OK.Nov 28, 1997 · N771NC · Doug DC951 · Emergency LightingSDR 9718009862Battery Pack · dischargedDURING LINE CHECK, FOUND OVERHEAD EMERGENCY LIGHTS INOPERATIVE ABOVE SEATS 13, 14 AND 15. REPLACED BATTERY PACK, OPERATIONAL CHECK OK.Sep 12, 1997 · N771NC · Doug DC951 · Emergency LightingSDR 9712989862Overheat Sensor · malfunctionedTAIL COMPARTMENT TEMPERATURE HIGH LIGHT ACCOMPANIED BY MASTER WARNING LIGHT ILLUMINATED DURING TAKEOFF ROLL. CREW ABORTED TAKEOFF AT 110 KNOTS AND AIRCRAFT WAS RETURNED TO THE GATE. MAINTENANCE INSPECTED SYSTEM AND NO LEAK OR PROBLEMS WERE FOUND. REPLACED TJul 2, 1997 · N771NC · Doug DC951 · Overheat DetectionSDR 9711239862Battery Pack · dischargedDURING LINE CHECK, FOUND SEVERAL CEILING EMERGENCY LIGHTS INOPERATIVE. REPLACED B5-58 BATTERY PACK AND BATTERIES, OPERATIONAL CHECK OK.May 30, 1997 · N771NC · Doug DC951 · Emergency LightingSDR 9707069862Epr Indicator · malfunctionedAS TAKEOFF POWER WAS APPLIED, THE LEFT ENGINE EPR INDICATION WOULD NOT REACH TARGET EPR LEVEL. CREW ABORTED TAKEOFF AND RETURNED TO GATE. MAINTENANCE REPLACED THE LEFT ENGINE EPR TRANSMITTER AND EPR INDICATOR. ENGINE OPERATIONAL CHECK WAS OK, ALL PARAMETERSApr 6, 1997 · N771NC · Doug DC951 · Engine Pressure Ratio (EPR)SDR 9706989862Amplifier · failedON CLIMBOUT, AIRCRAFT FAILED TO PRESSURIZE. FOLLOWED COCKPIT OPERATING MANUAL PROCEDURE AND RETURNED TO DTW. FLIGHT LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED THE PRESSURE CONTROL AMPLIFIER, SYSTEM OPERATIONAL CHECK OK.Apr 2, 1997 · N771NC · Doug DC951 · Cabin Pressure Control SystemSDR 9619929862Batteries · dischargedDURING LINE CHECK, FOUND THE LEFT AND RIGHT OVERWING EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERIES, OPERATIONAL CHECK OK.Sep 10, 1996 · N771NC · Doug DC951 · Emergency LightingSDR 9613389862Gasket · failedDURING CLIMBOUT OF DTW, THE TAIL COMPARTMENT TEMPERATURE ANNUNCIATOR AND MASTER WARNING LIGHT ILLUMINATED. REDUCED POWER AND WENT TO HP BLEED OFF ON PACKS AND LIGHTS WENT OUT. RESUMED POWER AND MASTER WARNING CAME ON MOMENTARILY AFTER ABOUT 5 MINUTES. RETURJun 18, 1996 · N771NC · Doug DC951 · Airfoil Anti/De-ice SystemSDR 9613399862Augmentation Vlv · malfunctionedDURING CRUISE WITH LEFT ANTI-ICE ON, THE LEFT ICE PROTECTION TEMPERATURE ANNUNCIATOR LIGHT ILLUMINATED. PERFORMED COM AND LIGHT WENT OUT. WHEN RIGHT SYSTEM WAS LATER SHUT DOWN BEFORE CROSSFEED CLOSED, THE RIGHT ICE PROTECTION TEMPERATURE ANNUNCIATOR LIGHT ILLJun 17, 1996 · N771NC · Doug DC951 · Airfoil Anti/De-ice SystemSDR 9611519862Skin · disbondedDURING FLIGHT, AN AIR LEAK WAS HEARD IN THE AFT CABIN. LANDED IN DTW WITHOUT FURTHER INCIDENT. FOUND APPROXIMATELY 18 TO 20 FASTENERS LOOSE ALONG THE FS 965 SKIN LAP SEAM FROM LONGERON 10L TO 10R. REPLACED LOOSE FASTENERS. PRESSURE CHECK REVEALED AN ADDITIMay 24, 1996 · N771NC · Doug DC951 · Fuselage Main, Plate/SkinSDR 9609359862Press Amplifier · broken wiresAFTER TAKEOFF, CABIN PRESSURIZATION STARTED CLIMBING AND DESCENDING ABOUT 800 FEET IN EACH DIRECTION. THE LEFT MAIN LANDING GEAR UNSAFE LIGHT REMAINED ILLUMINATED. ACFT RETURNED TO ATL AND LANDED WITHOUT INCIDENT. FOUND WIRES H538A24-RD AND H539A24-BL BROKEApr 27, 1996 · N771NC · Doug DC951 · Cabin Pressure Control SystemSDR 9610919862Bulkhead Former · crackedDURING H-CHECK, FOUND A .50 INCH CRACK IN THE AFT PRESSURE BULKHEAD HORIZONTAL FORMER AT Z=14. REPAIRED FORMER (P/N 9915558-27) PER EA 98-108866.Apr 18, 1996 · N771NC · Doug DC951 · Fuselage Main, BulkheadSDR 9608859862Fitting · corrodedDURING H-CHECK, FOUND CORROSION IN THE NR 3 FORWARD FLAP HINGE FITTING BOLT HOLE. REPLACED FITTING (P/N 5919217-502) PER CITEXT 90-2750-1-9806.Apr 18, 1996 · N771NC · Doug DC951 · Wing, Control Surface Attach FittingsSDR 9608849862Fitting · crackedDURING H-CHECK, FOUND A CRACK IN THE LONGERON 25R END FITTING AT FS 674. REPLACED FITTING PER SRM 51-30.Apr 18, 1996 · N771NC · Doug DC951 · Fuselage Miscellaneous StructureSDR 9521449862Batteries · dischargedDURING LINE MAINTENANCE INSPECTION, FOUND OVERHEAD EMERGENCY LIGHTS AT ROWS 20 THROUGH 24 INOPERATIVE. REPLACED BATTERIES IN PACK AT AFT CABIN AND OPERATIONAL CHECK NORMAL.Dec 22, 1995 · N771NC · Doug DC951 · Emergency LightingSDR 9500349862Fuel Temp Sensor · defectiveAFTER DEPARTURE, THE NR 2 FUEL TEMPERATURE WAS FLUCTUATING FROM PLUS 30 TO MINUS 60 DEGREES. AIRCRAFT RETURNED TO DTW AND LANDED WITHOUT INCIDENT. FOUND FUEL TEMPERATURE SENSOR DEFECTIVE. REPLACED SENSOR. ENGINE TUNE-UP CHECKED OK. AIRCRAFT RETURNED TO SEJan 8, 1995 · N771NC · Doug DC951 · Engine Fuel Indicating System
Back to N771NC, cancelled May 11, 2015