SDR 97ZZZX4390Valve · o-ring brokenLANDING GEAR SELECTOR VALVE INTERNAL O-RINGS FAILED CAUSING HYDRAULIC PUMP TO RUN CONTINUOUSLY.SDR 97ZZZX4389Valve · o-ring failedRECEIVED NEW VALVE FROM PIPER, BUT VALVE WAS DATED '4Q86'. INSTALLED VALVE AND CYCLED GEAR. THE OUTDATED O-RINGS IN VALVE 'BLEW OUT' ON THE FIRST RUN.